• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Correction of partial volume effect in SPECT/PET using anatomical information

Research Project

Project/Area Number 15591273
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionOsaka University

Principal Investigator

MURASE Kenya  Osaka University, Graduate School of Medicine, Professor, 大学院・医学系研究科, 教授 (50157773)

Co-Investigator(Kenkyū-buntansha) HATAZAWA Jun  Osaka University, Graduate School of Medicine, professor, 大学院・医学系研究科, 教授 (70198745)
OKU Naohiko  Osaka University, Hospital, Lecturer, 医学部附属病院, 講師 (40346193)
INOUE Osamu  Osaka University, Graduate School of Medicine, Professor, 大学院・医学系研究科, 教授 (50159969)
TAMURA Shinichi  Osaka University, Graduate School of Medicine, Professor, 大学院・医学系研究科, 教授 (30029540)
Project Period (FY) 2003 – 2004
Project Status Completed (Fiscal Year 2004)
Budget Amount *help
¥3,200,000 (Direct Cost: ¥3,200,000)
Fiscal Year 2004: ¥1,300,000 (Direct Cost: ¥1,300,000)
Fiscal Year 2003: ¥1,900,000 (Direct Cost: ¥1,900,000)
KeywordsSPECT / PET / partial volume effect / anatomical information / Bayesian image reconstruction method / MRI / fuzzy clustering / Tc-99m HMPAO / ^<99m>Tc HMPAO
Research Abstract

To accurately and quantitatively measure the distribution of radioisotope in the body using single photon emission computed tomography (SPECT) or positron emission tomography (PET), it is important to accurately correct for the partial volume effect (PVE). However, the correction of PVE is more difficult than that of attenuation and/or scattering in the body. On the other hand, it is possible to extract the anatomical information of the body from magnetic resonance imaging (MRI) using the segmentation method such as fuzzy clustering. Then, it is expected that if the anatomical information extracted from MRI can be introduced as a prior knowledge in the Bayesian image reconstruction method, it becomes possible to correct for PVE in SPECT or PET. Therefore, the purpose of this study was to develop a method for correcting for PVE in SPECT or PET by introducing the anatomical information extracted from MRI in the Bayesian image reconstruction method.
In 2003, we developed a software that introduces the anatomical information extracted from MRI as a prior knowledge in the Bayesian image reconstruction method. In 2004, we continued to develop the above software, and simultaneously started to evaluate the usefulness of this method using phantom experiments and clinical data. We obtained the preliminary results that encouraged the possibility of correcting for PVE using the above method.
In conclusion, this method appears to be useful for correcting for PVE in SPECT or PET. However, further studies are necessary to establish the usefulness of this method, and these studies are currently in progress.

Report

(3 results)
  • 2004 Annual Research Report   Final Research Report Summary
  • 2003 Annual Research Report
  • Research Products

    (26 results)

All 2004 2003 Other

All Journal Article (17 results) Book (2 results) Publications (7 results)

  • [Journal Article] Heterogeneity of cerebral blood flow in frontotemporal lobar degeneration and Alzheimer's disease2004

    • Author(s)
      Nagao M, Sugawara Y, Fukuhara R, Murase K
    • Journal Title

      Eur J Nucl Med Mol Imaging 31・2

      Pages: 162-168

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] Extraction of arterial input function for measurement of brain perfusion index with ^<99m>Tc compounds2004

    • Author(s)
      Murase K, Nagayoshi M, Uenishi Y, Kawamata M
    • Journal Title

      Nucl Med Commun 25・3

      Pages: 299-303

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Annual Research Report 2004 Final Research Report Summary
  • [Journal Article] Truncation correction of fan beam transmission data for attenuation correction using parallel beam2004

    • Author(s)
      Takahashi Y, Murase K, Mochizuki T, Higashino H
    • Journal Title

      Nucl Med Commun 25・6

      Pages: 623-630

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] Efficient method of calculating kinetic parameters using T1-weighted dynamic contrast2004

    • Author(s)
      Murase K
    • Journal Title

      Magn Reson Med 51・4

      Pages: 858-862

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] Segmented attenuation correction for myocardial SPECT2004

    • Author(s)
      Takahashi Y, Murase K, Mochizuki T, Higashino H
    • Journal Title

      Ann Nucl Med 18・2

      Pages: 137-143

    • NAID

      10017669315

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Annual Research Report 2004 Final Research Report Summary
  • [Journal Article] Superimposed display of coronary artery on gated myocardial perfusion scintigraphy2004

    • Author(s)
      Nishimura Y, Fukuchi K, Katafuchi T, Murase K
    • Journal Title

      J Nucl Med 45・9

      Pages: 1444-1449

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Annual Research Report 2004 Final Research Report Summary
  • [Journal Article] Heterogeneity of cerebral blood flow in frontotemporal lobar degeneration and Alzheimer's disease2004

    • Author(s)
      Nagao M, Sugawara Y, Ikeda M, Fukuhara R, Hokoishi K, Murase K, Mochizuki T, Miki H, Kikuchi T.
    • Journal Title

      Eur J Nucl Med Mol Imaging 31-2

      Pages: 162-168

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] Extraction of arterial input function for measurement of brain perfusion index with ^<99m>Tc compounds using fuzzy clustering2004

    • Author(s)
      Murase K, Nagayoshi M, Uenishi Y, Kawamata M, Yamazaki Y, Takasawa M, Oku N, Hatazawa J.
    • Journal Title

      Nucl Med Commun 25-3

      Pages: 299-303

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] Truncation correction of fan beam transmission data for attenuation correction using parallel beam emission data on a 3-detector SPECT system2004

    • Author(s)
      Takahashi Y, Murase K, Mochizuki T, Higashino H, Motomura N.
    • Journal Title

      Nucl Med Commun 25-6

      Pages: 623-630

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] Efficient method for calculating kinetic parameters using T1-weighted dynamic contrast-enhanced magnetic resonance imaging2004

    • Author(s)
      Murase K.
    • Journal Title

      Magn Reson Med 51-4

      Pages: 858-862

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] Segmented attenuation correction for myocardial SPECT2004

    • Author(s)
      Takahashi Y, Murase K, Mochizuki T, Higashino H, Sugawara Y, Kinda A.
    • Journal Title

      Ann Nucl Med 18-2

      Pages: 137-143

    • NAID

      10017669315

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] Superimposed display of coronary artery on gated myocardial perfusion scintigraphy2004

    • Author(s)
      Nishimura Y, Fukuchi K, Katafuchi T, Sagou M, Oka H, Ishida Y, Murase K.
    • Journal Title

      J Nucl Med 45-9

      Pages: 1444-1449

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] Spectral analysis of ^<99m>Tc-HMPAO for estimating cerebral blood flow : a comparison with H_2^<15>O PET2004

    • Author(s)
      Takasawa M, Murase K, Oku N, Kawamata M, Nagayoshi M, Imaizumi M, Yoshikawa T, Osaki Y, Kimura Y, Kajimoto K, Kitagawa K, Hori M, Hatazawa J.
    • Journal Title

      Ann Nucl Med 18-3

      Pages: 243-249

    • NAID

      10017669745

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] Heterogeneity of cerebral blood flow in frontotemporal lobar degeneration and Alzheimer's disease2004

    • Author(s)
      Nagao M, Sugawara Y, Ikeda M, Fukuhara R, Hokoishi K, Murase K
    • Journal Title

      Eur J Nucl Med Mol Imaging 31・2

      Pages: 162-168

    • Related Report
      2004 Annual Research Report
  • [Journal Article] Truncation correction of fan beam transmission data for attenuation correction using parallel beam2004

    • Author(s)
      Takahashi Y, Murase K, Mochizuki T, Higashino H
    • Journal Title

      Nucl.Med.Commun 25・6

      Pages: 623-630

    • Related Report
      2004 Annual Research Report
  • [Journal Article] Efficient method for calculating Kinetic parameters using T1-weighted dynamic contrast2004

    • Author(s)
      Murase K
    • Journal Title

      Magn Reson Med 51・4

      Pages: 858-862

    • Related Report
      2004 Annual Research Report
  • [Journal Article] Evaluation of the number of SPECT projections in the ordered subsets-expectation maximization image reconstruction method2003

    • Author(s)
      Takahashi Y, Murase K, Mochizuki T, Higashino H, Sugawara Y, Kinda A.
    • Journal Title

      Ann Nucl Med 17-7

      Pages: 525-530

    • NAID

      10017668393

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Book] 新・医用放射線技術実験2004

    • Author(s)
      村瀬 研也
    • Total Pages
      320
    • Publisher
      共立出版
    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Book] 新・医用放射線技術実験2004

    • Author(s)
      村瀬研也
    • Total Pages
      320
    • Publisher
      共立出版
    • Related Report
      2004 Annual Research Report
  • [Publications] Murase K, Yamazaki Y, Shinohara M: "Autoregressive moving average (ARMA) model applied to quautification of cerebral blood flow"Magnetic Resonance in Medicine. 2(2). 85-95 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] Murase K: "Spectral Analysis : principle and clinical applications"Annals of Nuclear Medicine. 17(6). 427-434 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] Nagao M, Sugawara Y, Murase K: "Heterogeneity of cerebral blood flow in frontotemporal lobar degeneration and Alzheimer's disease"European Journal of Nuclear Medicine. 31・2. 162-168 (2004)

    • Related Report
      2003 Annual Research Report
  • [Publications] Murase K, Nagayoshi M, Uenishi Y, Kawamata M: "Extraction of artevial input function for measurement of brain perfusion index"Nuclear Medicine Communications. (印刷中).

    • Related Report
      2003 Annual Research Report
  • [Publications] Murase K: "Efficient method for calculating kinetic parameters using T_1-weighted dynamic contrast-enhanced MRI"Magnetic Resonance in Medicine. (印刷中).

    • Related Report
      2003 Annual Research Report
  • [Publications] Yamada S, Murase K: "The quantitative analysis of resolving power for computed radiographic portal images"Japanese Journal of Medical Physics. (印刷中).

    • Related Report
      2003 Annual Research Report
  • [Publications] 村瀬研也: "新・医用放射線技術実験"共立出版(印刷中). (2004)

    • Related Report
      2003 Annual Research Report

URL: 

Published: 2003-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi