Implant placement in irradiated bone ?Effects of hydroxyapatite after anodic oxidation and hydrothermal treatment

Research Project

Project/Area Number 15592061
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field 補綴理工系歯学
Research InstitutionIwate Medical University

Principal Investigator

ITOH Sozo  Iwate Medical University, School of Dentistry, Assistant Professor, 歯学部, 講師 (60203139)

Co-Investigator(Kenkyū-buntansha) ISHIBASHI Kanji  Iwate Medical University, school of Dentistry, Professor, 歯学部, 教授 (90018771)
Project Period (FY) 2003 – 2004
Project Status Completed (Fiscal Year 2004)
Budget Amount *help
¥3,400,000 (Direct Cost: ¥3,400,000)
Fiscal Year 2004: ¥1,600,000 (Direct Cost: ¥1,600,000)
Fiscal Year 2003: ¥1,800,000 (Direct Cost: ¥1,800,000)
KeywordsIimplant / Osseointegration / Maxillofacial prosthesis / Rradiation / Bone / Titanium / Aanodic oxidation / Hhydrothermal treatment / 顎顔面補綴
Research Abstract

Purpose:
Although there have been several reports concerning the use of osseointegrated implants for maxillofacial prosthesis, little is still understood about the effects of radiation on the bone/titanium interface. Since it is quite important to know this relationship when dealing with cases where implants have been inserted into the bone after radiotherapy. We reported that the primary stage of calification on the bone/titanium interface was affected upon the amount of radiation exposure. In this study, we use the pure Ti rods in vivo experiment and measured bonding strength to irradiated bone.
Method:
Tapered pure titanium rods that were 1-2 mm in diameter and 15 mm in length were employed. The surface of titanium was machine polished. Under general anesthesia, approximately 0.04Gy, 0.4Gy, 4Gy, 40Gy was irradiated to each one side femoral of Japanese white rabbits. After 24hours, three titanium rods were inserted into drilled holes press-fitted to a tapered shape in the each femoral. At 2 or 3weeks after insertion, the specimens were harvested, and a push-out test was performed at a crosshead speed of 0.5 mm/mm. Afterwards, the surfaces of the specimens were observed by a SEM and EDX (Energy Dispersive X-ray Fluores cence Spectrometer).
Results:
Irradiation doses under 4Gy induced no significant changes of the strength between the bone/titanium interfaces.
The bone bonding strength were affected upon 40Gy radiation exposure after 3weeks implantation.
CONCLUSION
The bone bonding strength between the bone/titanium interfaces were affected upon the amount of radiation exposure.