• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Research title : Objective asesssment of anesthetic depth under general anesthesia and conscious sedation using BIS monitor

Research Project

Project/Area Number 15592140
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Surgical dentistry
Research InstitutionNihon University

Principal Investigator

SHIBUTANI Koh  Nihon University, School of Dentistry at Matsudo, Professor, 松戸歯学部, 教授 (70130523)

Co-Investigator(Kenkyū-buntansha) UDA Akio  Nihon University, School of Dentistry at Matsudo, Lecturer (Full-Time), 松戸歯学部, 講師 (30277470)
YAMAGUCHI Hidenori  Nihon University, School of Dentistry at Matsudo, Lecturer (Full-Time), 松戸歯学部, 講師 (50220273)
SHIMOSAKA Michiharu  Nihon University, School of Dentistry at Matsudo, Research Assistant (Full-Time), 松戸歯学部, 助手 (90297854)
SUZUKI Masatoshi  Nihon University, School of Dentistry at Matsudo, Research Assistant (Full-Time), 松戸歯学部, 助手 (60366614)
Project Period (FY) 2003 – 2005
Project Status Completed (Fiscal Year 2005)
Budget Amount *help
¥3,600,000 (Direct Cost: ¥3,600,000)
Fiscal Year 2005: ¥300,000 (Direct Cost: ¥300,000)
Fiscal Year 2004: ¥300,000 (Direct Cost: ¥300,000)
Fiscal Year 2003: ¥3,000,000 (Direct Cost: ¥3,000,000)
KeywordsBispectral Index / Target Control Infusion / intravenous sadation / propofol / amnestic effects / pre-medication / 覚醒刺激 / BIS / 全身麻酔 / 精神鎮静法 / 催眠レベル / 記憶 / 血中濃度
Research Abstract

The Bispectral Index (BIS) monitor is used to assess anesthetic depth during anesthesia, and the present study investigated amnestic effects, estimated cerebral concentration of propofol (PPF), and BIS value following PPF administration by target control infusion.
[Experiment 1] As a basic experiment, the relationship between the BIS value during PPF administration and estimated cerebral concentration of PPF was investigated, which revealed that a correlation existed between the BIS value and estimated cerebral concentration. However, the assessment of consciousness and amenesia levels based on the BIS value proved impossible.
[Experiment 2] The amnestic effects of PPF during sedation induction and awakening were investigated. During the induction, amnestic effects were obtained at an estimated cerebral concentration of 0.91±0.21μg/ml, and during awakening, amnestic effects were obtained at an estimated cerebral concentration of 0.65±0.18μg/ml. Therefore, when under sedation, amnestic ef … More fects could be maintained at a lower concentration of PPF when compared to induction.
[Experiment 3] During awakening following PPF administration, the effects of awakening stimulation on BIS value and post-sedation amnestic effects were investigated. The results showed that there was a rapid increase in BIS value if awakening stimulation was actively delivered after PPF administration. When awakening stimulation was delivered, although the estimated cerebral concentration of PPF was high, amnestic effects were lost and memory was regained. However, the BIS value required for memory recovery ranged widely, and no consistent tendencies were observed.
[Experiment 4] In patients who were scheduled to undergo general anesthesia, in order to ascertain the effects of pre-medication on preoperative BIS value and memory, BIS value and amnestic effects were assessed upon the patient's entry in the operating room. The results showed significant differences in BIS value and amnestic effects among the different types of pre-medication. This suggests that the BIS monitor is also useful in assessing pre-medication. Less

Report

(4 results)
  • 2005 Annual Research Report   Final Research Report Summary
  • 2004 Annual Research Report
  • 2003 Annual Research Report
  • Research Products

    (6 results)

All 2005 2004

All Journal Article (6 results)

  • [Journal Article] プロポフォール静脈内鎮静法の覚醒時における健忘効果の観察2005

    • Author(s)
      山口秀紀
    • Journal Title

      日本歯科麻酔学会雑誌 33巻・4号

      Pages: 127-127

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2005 Final Research Report Summary
  • [Journal Article] プロポフォール静脈内鎮静法の覚醒時における健忘効果の観察2005

    • Author(s)
      山口秀紀
    • Journal Title

      日本歯科麻酔学会雑誌 33・4

      Pages: 127-127

    • Related Report
      2005 Annual Research Report
  • [Journal Article] 推定脳内濃度からみたプロポフォールの健忘効果に及ぼす影響2004

    • Author(s)
      山口秀紀
    • Journal Title

      日本歯科麻酔学会雑誌 32巻・4号

      Pages: 72-72

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2005 Final Research Report Summary
  • [Journal Article] Amnestic effects of propofol as examined based on estimated cerebral concentration2004

    • Author(s)
      Hidenori Yamaguchi
    • Journal Title

      Journal of Japan Dental Society of Anesthesiology Vol32・4

      Pages: 72-72

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2005 Final Research Report Summary
  • [Journal Article] Amnestic effects during awakening from intravenous propofol sedation2004

    • Author(s)
      Hidenori Yamachchi
    • Journal Title

      Journal of Japan Dental Society of Anesthesiology Vol34・4

      Pages: 127-127

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2005 Final Research Report Summary
  • [Journal Article] 推定血中濃度からみたプロポフォールの健忘効果におよぼす影響2004

    • Author(s)
      山口秀紀
    • Journal Title

      日本歯科麻酔学会雑誌 32巻・4号

      Pages: 72-72

    • Related Report
      2004 Annual Research Report

URL: 

Published: 2003-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi