• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Mitigation of global warming by the introduction of highly efficient and cost effective GSHP systems using urban infrastructures

Research Project

Project/Area Number 15H04223
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section一般
Research Field Earth system and resources engineering
Research InstitutionAkita University

Principal Investigator

Fujii Hikari  秋田大学, 国際資源学研究科, 教授 (80332526)

Co-Investigator(Kenkyū-buntansha) 内田 洋平  国立研究開発法人産業技術総合研究所, エネルギー・環境領域, 研究チーム長 (90356577)
Project Period (FY) 2015-04-01 – 2019-03-31
Project Status Completed (Fiscal Year 2018)
Budget Amount *help
¥16,120,000 (Direct Cost: ¥12,400,000、Indirect Cost: ¥3,720,000)
Fiscal Year 2018: ¥2,990,000 (Direct Cost: ¥2,300,000、Indirect Cost: ¥690,000)
Fiscal Year 2017: ¥6,630,000 (Direct Cost: ¥5,100,000、Indirect Cost: ¥1,530,000)
Fiscal Year 2016: ¥2,860,000 (Direct Cost: ¥2,200,000、Indirect Cost: ¥660,000)
Fiscal Year 2015: ¥3,640,000 (Direct Cost: ¥2,800,000、Indirect Cost: ¥840,000)
Keywords地中熱利用 / 温暖化対策 / 都市インフラ / 地中熱交換器 / シミュレーション / 省エネルギー / フィールド試験
Outline of Final Research Achievements

In this research, we conducted a series of research aimed at practical application of installation of low-cost horizontal ground heat exchangers in ground source heat pump systems to urban infrastructure such as underground tunnels and buildings. In the field tests conducted at the actual scale facilities installed in Akita City and Saga City, we found that the behavior of the horizontal ground heat exchanger is strongly affected by the ground surface coverages, and the no-dig method is a promising installation methods of heat exchangers Furthermore, with regard to the heating and cooling system installed in the underground tunnel of Odakyu Electric Railway, operation data analysis and numerical calculation were performed, and it was confirmed that the system has high energy saving performance and long-term stability compared with the conventional system. These results proved that the introduction of the geothermal heat utilization system to the infrastructure was effective.

Academic Significance and Societal Importance of the Research Achievements

鉄道トンネルで実施した長期冷暖房試験のデータ解析やシミュレーションはこれまで実施例がなく,また地盤中の温度安定性による高効率性が初めて示された研究であり,学術的意義が大きいと判断される。また,非開削工法の地中熱利用への本格的導入例は国内外で見られず,有意義かつ先進性が高い取り組みであった。
本研究の成果により地中熱利用システムが都市部に普及した場合,建築物のエネルギー需要の大きな部分を占める冷暖房消費電力が大きく削減されるため,省エネルギーと温暖化対策への重要な貢献が期待される。さらに,地中熱利用システムの都市部への導入はヒートアイランド現象の緩和に大きく寄与するため,社会的意義が大きい。

Report

(5 results)
  • 2018 Annual Research Report   Final Research Report ( PDF )
  • 2017 Annual Research Report
  • 2016 Annual Research Report
  • 2015 Annual Research Report
  • Research Products

    (53 results)

All 2019 2018 2017 2016 2015

All Journal Article (25 results) (of which Int'l Joint Research: 6 results,  Peer Reviewed: 19 results,  Open Access: 7 results,  Acknowledgement Compliant: 5 results) Presentation (26 results) (of which Int'l Joint Research: 9 results) Patent(Industrial Property Rights) (2 results)

  • [Journal Article] Field Test of Horizontal Ground Heat Exchangers installed using Horizontal Directional Drilling Technology2019

    • Author(s)
      Fujii, H., Tsuya, S., Harada, R., Kosukegawa, H.
    • Journal Title

      Proc. Stanford Geothermal Workshop 2019

      Pages: 922-929

    • Related Report
      2018 Annual Research Report
  • [Journal Article] Long-term heating test using the semi-open loop ground source heat pump system2019

    • Author(s)
      Kosukegawa, H., Fujii, H.
    • Journal Title

      Proc. Stanford Geothermal Workshop 2019

      Pages: 965-972

    • Related Report
      2018 Annual Research Report
  • [Journal Article] 数値シミュレーションによる帯水層蓄熱冷暖房システムの地下環境への影響抑制に関する検討2018

    • Author(s)
      桂木聖彦・藤井 光・井上 純・山谷 睦・黒沼 覚
    • Journal Title

      日本地熱学会誌

      Volume: 40 Pages: 97-108

    • Related Report
      2018 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Relationship between ground temperature behavior and ground surface coverage in Slinky-coil type horizontal ground heat exchanger2018

    • Author(s)
      Tsuya, S., Fujii, H., Kosukegawa, H.
    • Journal Title

      Proc. Grand Renewable Energy 2018

    • NAID

      130007608645

    • Related Report
      2018 Annual Research Report
  • [Journal Article] Numerical Simulation of Slinky-coil Ground Heat Exchangers Installed in Railway Tunnels2018

    • Author(s)
      Fujii, H., Taniguchi, S., Ogai, K.
    • Journal Title

      Proc. 2nd IGSHPA Research Track

      Pages: 346-353

    • Related Report
      2018 Annual Research Report
    • Peer Reviewed
  • [Journal Article] A Pilot Study on Geothermal Heat Pump (GHP) Use for Cooling Operations, and on GHP Site Selection in Tropical Regions Based on a Case Study in Thailand2018

    • Author(s)
      Sasimook, C., Srilert, C., Takashima, I., Uchida. Y., Arif, W., Yasukawa, K. and Punya, C.
    • Journal Title

      Energies

      Volume: 11 Issue: 9 Pages: 2356-2356

    • DOI

      10.3390/en11092356

    • Related Report
      2018 Annual Research Report
    • Peer Reviewed / Open Access / Int'l Joint Research
  • [Journal Article] Factors Affecting the Installation Potential of Ground Source Heat Pump Systems: A Comparative Study for the Sendai Plain and Aizu Basin2018

    • Author(s)
      Kaneko, S., Uchida, Y., Shrestha, G., Ishihara, T. and Yoshioka, M.
    • Journal Title

      Energies

      Volume: 11 Issue: 10 Pages: 2860-2860

    • DOI

      10.3390/en11102860

    • Related Report
      2018 Annual Research Report
    • Peer Reviewed / Open Access / Int'l Joint Research
  • [Journal Article] Analysis of Shallow Subsurface Geological Structures and Ground Effective Thermal Conductivity for the Evaluation of Ground-Source Heat Pump System Installation in the Aizu Basin, Northeast Japan2018

    • Author(s)
      Ishihara, T., Shrestha, G., Kaneko, S. and Uchida, Y.
    • Journal Title

      Energies

      Volume: 11 Issue: 8 Pages: 2098-2098

    • DOI

      10.3390/en11082098

    • Related Report
      2018 Annual Research Report
    • Peer Reviewed / Open Access / Int'l Joint Research
  • [Journal Article] Assessment of the Installation Potential of a Ground Source Heat Pump System Based on the Groundwater Condition in the Aizu Basin, Japan2018

    • Author(s)
      Shrestha, G., Uchida, Y., Ishihara, T., Kaneko, S. and Kuronuma, S.
    • Journal Title

      Energies

      Volume: 11 Issue: 5 Pages: 1178-1178

    • DOI

      10.3390/en11051178

    • Related Report
      2018 Annual Research Report
    • Peer Reviewed / Open Access / Int'l Joint Research
  • [Journal Article] Semi-open Loop Ground Source Heat Pump System: Heating Tests, Numerical Modeling and Sensitivity Analysis2018

    • Author(s)
      Farabi Asl, H., Fujii, H., Kosukegawa, H.
    • Journal Title

      Geothermics

      Volume: 71 Pages: 34-45

    • DOI

      10.1016/j.geothermics.2017.08.005

    • Related Report
      2017 Annual Research Report
    • Peer Reviewed / Open Access
  • [Journal Article] Estimation of groundwater flow from temperature monitoring in a borehole heat exchanger during a thermal response test2018

    • Author(s)
      Yoshioka, M., Takakura, S., Uchida, Y.
    • Journal Title

      Hydrogeogy Jounranl

      Volume: 26 Issue: 3 Pages: 853-867

    • DOI

      10.1007/s10040-017-1701-2

    • Related Report
      2017 Annual Research Report
    • Peer Reviewed
  • [Journal Article] 鉄道トンネル下床版下に設置したSlinky-coil式地中熱交換器の挙動解析と数値シミュレーション2017

    • Author(s)
      藤井 光・尾ヶ井佳祐・ハディ ファラビ アスル・石上 孝・谷口聡子
    • Journal Title

      日本地熱学会誌

      Volume: 39 Pages: 157-165

    • NAID

      130006318962

    • Related Report
      2017 Annual Research Report
    • Peer Reviewed / Open Access
  • [Journal Article] Experimental study on pressure loss calculation for Slinky-coil heat exchangers2017

    • Author(s)
      Kosukegawa, H., Fujii, H.
    • Journal Title

      Geothermal Resources Council Transactions

      Volume: 41 Pages: 145-154

    • Related Report
      2017 Annual Research Report
  • [Journal Article] Analysis of operation behavior and numerical simulation of a large-scale borehole field2017

    • Author(s)
      Tsuya, S., Fujii, H., Kodama, A.
    • Journal Title

      Geothermal Resources Council Transactions

      Volume: 41 Pages: 246-257

    • Related Report
      2017 Annual Research Report
    • Peer Reviewed
  • [Journal Article] 地域の水文環境を活用した地中熱交換器の開発2017

    • Author(s)
      内田洋平・吉岡真弓・シュレスタ ガウラブ・黒沼 覚
    • Journal Title

      Kansai Geo-Symposium 2017 論文集

    • Related Report
      2017 Annual Research Report
  • [Journal Article] 坑井内での注水や揚を伴う地中熱交換システムシステムに関する数値シミュレーョン2017

    • Author(s)
      浅井寛明・糸井龍一・藤井光
    • Journal Title

      日本地熱学会誌

      Volume: 39 Pages: 39-48

    • Related Report
      2016 Annual Research Report
    • Peer Reviewed / Acknowledgement Compliant
  • [Journal Article] Semi-open Loop Ground Source Heat Pump System: Heating Tests, Numerical Modeling and Sensitivity Analysis2017

    • Author(s)
      Farabi, H., Fujii, H., Kosukegawa, H.
    • Journal Title

      日本地熱学会誌

      Volume: 39

    • Related Report
      2016 Annual Research Report
    • Peer Reviewed / Acknowledgement Compliant
  • [Journal Article] Slinky-Coil式地中熱交換器の管内圧力損失に関する実験的検討2017

    • Author(s)
      小助川洋幸・藤井光・小野雅敏
    • Journal Title

      日本地熱学会誌

      Volume: 39

    • NAID

      130006182218

    • Related Report
      2016 Annual Research Report
    • Peer Reviewed / Acknowledgement Compliant
  • [Journal Article] Performance evaluation of a ground-source heat pump system utilizing a flowing well and estimation of suitable areas for its installation in Aizu Basin, Japan2017

    • Author(s)
      Shrestha, G., Uchida, Y., Kuronuma, S., Yamaya, M. Katsuragi M. Kaneko, S. Shibasaki, N. and Yoshioka, M
    • Journal Title

      Hydrogeology Journal, Springer

      Volume: 1 Issue: 5 Pages: 1-14

    • DOI

      10.1007/s10040-017-1536-x

    • Related Report
      2016 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Development of ground-source heat pump system using a flowing well2017

    • Author(s)
      Shrestha, G., Uchida, Y., Kuronuma, S., Yamaya, M. Katsuragi
    • Journal Title

      The 11th Asian Geothermal Symposium, Proceedings

      Volume: -

    • Related Report
      2016 Annual Research Report
  • [Journal Article] サーマルレスポンス試験の非充填型熱交換井への適用に関する実験的検討2016

    • Author(s)
      藤井光・小助川洋幸・ハディ ファラビ・サイード ジャリリ
    • Journal Title

      日本地熱学会誌

      Volume: 38

    • NAID

      130005249792

    • Related Report
      2015 Annual Research Report
    • Peer Reviewed / Acknowledgement Compliant
  • [Journal Article] Ground Heat Transfer from a Drainage Trench2016

    • Author(s)
      Bottarelli, M., Fujii, H., Di Federico, V.
    • Journal Title

      Special Topics & Review in Porous Media – An International Journal

      Volume: 6 Pages: 185-195

    • Related Report
      2015 Annual Research Report
    • Peer Reviewed / Open Access / Int'l Joint Research
  • [Journal Article] Effect of water injection into a ground heat exchanger drilled in a low-λ formation2015

    • Author(s)
      Fujii, H., Kosukegawa, H., Onishi, K.
    • Journal Title

      Proc. World Geothermal Congress 2015

      Volume: - Pages: 1-8

    • Related Report
      2015 Annual Research Report
    • Peer Reviewed / Acknowledgement Compliant
  • [Journal Article] Performance expectation of a geothermal heat pump system using a numerical model2015

    • Author(s)
      Shim, B.O., Park, H.E., Lee, C., Fujii, H.
    • Journal Title

      Proc. World Geothermal Congress 2015

      Volume: - Pages: 1-3

    • Related Report
      2015 Annual Research Report
    • Peer Reviewed / Int'l Joint Research
  • [Journal Article] 地中熱ヒートポンプシステムにおけるポテンシャルマップの高度化2015

    • Author(s)
      シュレスタ ガウラブ・内田洋平・吉岡真弓・藤井 光・井岡聖一郎
    • Journal Title

      日本地熱学会誌

      Volume: 37 Pages: 133-141

    • NAID

      130005146439

    • Related Report
      2015 Annual Research Report
    • Peer Reviewed
  • [Presentation] Field Test of Horizontal Ground Heat Exchangers installed using Horizontal Directional Drilling Technology2019

    • Author(s)
      Fujii, H., Tsuya, S., Harada, R., Kosukegawa, H.
    • Organizer
      Stanford Geothermal Workshop 2019
    • Related Report
      2018 Annual Research Report
    • Int'l Joint Research
  • [Presentation] Long-term heating test using the semi-open loop ground source heat pump system2019

    • Author(s)
      Kosukegawa, H., Fujii, H.
    • Organizer
      Stanford Geothermal Workshop 2019
    • Related Report
      2018 Annual Research Report
    • Int'l Joint Research
  • [Presentation] Numerical Simulation of Slinky-coil Ground Heat Exchangers Installed in Railway Tunnels2018

    • Author(s)
      Fujii, H., Taniguchi, S., Ogai, K.
    • Organizer
      2nd IGSHPA Research Track
    • Related Report
      2018 Annual Research Report
    • Int'l Joint Research
  • [Presentation] Relationship between ground temperature behavior and ground surface coverage in Slinky-coil type horizontal ground heat exchanger2018

    • Author(s)
      Tsuya, S., Fujii, H., Kosukegawa, H.
    • Organizer
      Grand Renewable Energy 2018
    • Related Report
      2018 Annual Research Report
    • Int'l Joint Research
  • [Presentation] Suitability assessment for installation of ground-source heat pump system2018

    • Author(s)
      Shrestha, G., Yoshioka, M., Uchida, Y., Ishihara, T. and Kaneko, S.
    • Organizer
      Grand Renewable Energy 2018
    • Related Report
      2018 Annual Research Report
    • Int'l Joint Research
  • [Presentation] CCOP Groundwater Project and Application of Ground Source Heat Pump System2018

    • Author(s)
      Uchida, Y., Shrestha, G., Takashima, I. Sasimook, C. and Tran, T, T.
    • Organizer
      Grand Renewable Energy 2018
    • Related Report
      2018 Annual Research Report
    • Int'l Joint Research
  • [Presentation] Comparison of geological structure with effective thermal conductivity of ground in the Aizu basin, Northeast Japan2018

    • Author(s)
      Ishihara, T., Shrestha, G., Kaneko, S. and Uchida, Y.
    • Organizer
      Grand Renewable Energy 2018
    • Related Report
      2018 Annual Research Report
    • Int'l Joint Research
  • [Presentation] Comparison of apparent thermal conductivity and thermal conductivity of core samples in the Sendai Plain, Japan2018

    • Author(s)
      Kaneko, S., Uchida, Y., Yoshioka, M., Shrestha, G., Ishihara, T. and Arif, W.
    • Organizer
      Grand Renewable Energy 2018
    • Related Report
      2018 Annual Research Report
    • Int'l Joint Research
  • [Presentation] 1m深地温測定による地球温暖化・ヒートアイランド現象の実証的理解(その3)2017

    • Author(s)
      江原 幸雄,藤井 光,野田 徹郎,松林 修,松本 光央,笹田 政克,神谷 章夫,福岡 晃一郎
    • Organizer
      日本地熱学会秋季講演会
    • Related Report
      2017 Annual Research Report
  • [Presentation] 大型建造物における大規模地中熱利用システムの運転挙動解析と数値シミュレーション2017

    • Author(s)
      小玉 歩,藤井 光,長尾 康香
    • Organizer
      日本地熱学会秋季講演会
    • Related Report
      2017 Annual Research Report
  • [Presentation] 半開放式地中熱利用システムにおける熱交換能力改善効果および経済性の評価2017

    • Author(s)
      小助川 洋幸,藤井 光,ハディ ファラビ アスル
    • Organizer
      日本地熱学会秋季講演会
    • Related Report
      2017 Annual Research Report
  • [Presentation] トリプルU字管地中熱交換器の挙動評価2017

    • Author(s)
      津谷 駿介,藤井 光,渡部 敦史
    • Organizer
      日本地熱学会秋季講演会
    • Related Report
      2017 Annual Research Report
  • [Presentation] 地中熱利用による地下微生物への影響評価2017

    • Author(s)
      谷口 聡子,渡部 敦史,浅野 貴博,高橋 唯,藤井 光,奥島 里美
    • Organizer
      日本地熱学会秋季講演会
    • Related Report
      2017 Annual Research Report
  • [Presentation] CCOP Groundwater Project and Application of Ground-Source Heat Pump System2016

    • Author(s)
      Uchida, Y., Shrestha, G., Takashima, I. and Ikawa, R.
    • Organizer
      The 3rd Asia Renewable Energy Workshop
    • Place of Presentation
      ハノイ
    • Year and Date
      2016-12-07
    • Related Report
      2016 Annual Research Report
  • [Presentation] 1m深地温測定による地球温暖化・ヒートアイランド現象の実証的理解(その2)2016

    • Author(s)
      江原 幸雄,藤井 光,野田 徹郎,松林 修,笹田 政克,神谷 章夫,福岡 晃一郎
    • Organizer
      日本地熱学会秋季講演会
    • Place of Presentation
      郡山市
    • Year and Date
      2016-10-19
    • Related Report
      2016 Annual Research Report
  • [Presentation] 鉄道トンネル下床盤下に設置したSlinky-coil式地中熱交換器の数値シミュレーション2016

    • Author(s)
      尾ケ井 佳祐,藤井 光,石上 孝,谷口 聡子
    • Organizer
      日本地熱学会秋季講演会
    • Place of Presentation
      郡山市
    • Year and Date
      2016-10-19
    • Related Report
      2016 Annual Research Report
  • [Presentation] Slinky-Coil式地中熱交換器の管内圧力損失に関する実験的検討2016

    • Author(s)
      小助川 洋幸,藤井 光,小野 雅敏
    • Organizer
      日本地熱学会秋季講演会
    • Place of Presentation
      郡山市
    • Year and Date
      2016-10-19
    • Related Report
      2016 Annual Research Report
  • [Presentation] 会津盆地における地中熱利用ポテンシャルマップの作成2016

    • Author(s)
      シュレスタ ガウラブ,内田 洋平,吉岡 真弓,金子 翔平,藤井 光
    • Organizer
      日本地熱学会秋季講演会
    • Place of Presentation
      郡山市
    • Year and Date
      2016-10-19
    • Related Report
      2016 Annual Research Report
  • [Presentation] コア試料を用いた熱物性計測と見かけ熱伝導率の比較検討2016

    • Author(s)
      吉岡 真弓,内田 洋平,石原 武志,藤井 光,山谷 睦
    • Organizer
      日本地熱学会秋季講演会
    • Place of Presentation
      郡山市
    • Year and Date
      2016-10-19
    • Related Report
      2016 Annual Research Report
  • [Presentation] 秋田市における1m深地温測定と地球温暖化の影響の検討2016

    • Author(s)
      津谷 駿介,藤井 光
    • Organizer
      日本地熱学会秋季講演会
    • Place of Presentation
      郡山市
    • Year and Date
      2016-10-19
    • Related Report
      2016 Annual Research Report
  • [Presentation] 地域の地下水・地質特性を活用した地中熱システムの開発2016

    • Author(s)
      内田洋平
    • Organizer
      第11回再生可能エネルギー世界展示会
    • Place of Presentation
      横浜市
    • Year and Date
      2016-07-05
    • Related Report
      2016 Annual Research Report
  • [Presentation] Performance evaluation of ground-source heat pump system and development of suitability map for its installation2015

    • Author(s)
      Shrestha G., Uchida Y., Yoshioka M., Kuronuma S., Kaneko S.
    • Organizer
      2015 AGU Fall Meeting
    • Place of Presentation
      米国サンフランシスコ
    • Year and Date
      2015-12-15
    • Related Report
      2015 Annual Research Report
    • Int'l Joint Research
  • [Presentation] 室内実験によるSlinky-Coil式地中熱交換器設計の最適化2015

    • Author(s)
      小助川洋幸,藤井光,射越大岳
    • Organizer
      日本地熱学会秋季講演会
    • Place of Presentation
      別府市
    • Year and Date
      2015-10-21
    • Related Report
      2015 Annual Research Report
  • [Presentation] サーマルレスポンス試験における非充填式熱交換井の適用性評価2015

    • Author(s)
      藤井光,小助川洋幸,ハディファラビ
    • Organizer
      日本地熱学会秋季講演会
    • Place of Presentation
      別府市
    • Year and Date
      2015-10-21
    • Related Report
      2015 Annual Research Report
  • [Presentation] 往き還りU字管内に光ファイバー温度計を設置したサーマルレスポンス試験の解析2015

    • Author(s)
      鈴木千広,藤井光,小助川洋幸
    • Organizer
      日本地熱学会秋季講演会
    • Place of Presentation
      別府市
    • Year and Date
      2015-10-21
    • Related Report
      2015 Annual Research Report
  • [Presentation] 青森県田舎館村における熱応答試験による浅層地盤の熱交換量の検証2015

    • Author(s)
      井岡聖一郎,藤井光,鈴木陽大,松田雅司,村岡洋文
    • Organizer
      日本地熱学会秋季講演会
    • Place of Presentation
      別府市
    • Year and Date
      2015-10-21
    • Related Report
      2015 Annual Research Report
  • [Patent(Industrial Property Rights)] 水平型地中熱交換器、および、地中熱利用空調システム2018

    • Inventor(s)
      藤井光、原田烈
    • Industrial Property Rights Holder
      藤井光、原田烈
    • Industrial Property Rights Type
      特許
    • Filing Date
      2018
    • Related Report
      2018 Annual Research Report
  • [Patent(Industrial Property Rights)] ヒートポンプシステム2016

    • Inventor(s)
      藤井光 他
    • Industrial Property Rights Holder
      藤井光 他
    • Industrial Property Rights Type
      特許
    • Filing Date
      2016-12-01
    • Related Report
      2016 Annual Research Report

URL: 

Published: 2015-04-16   Modified: 2020-03-30  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi