• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

A cadaveric biomechanical study designed to test between the pullout strength and the finite element method (FEM)

Research Project

Project/Area Number 15K10408
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeMulti-year Fund
Section一般
Research Field Orthopaedic surgery
Research InstitutionThe University of Tokushima

Principal Investigator

HIGASHINO Kosaku  徳島大学, 大学院医歯薬学研究部(医学系), 徳島大学専門研究員 (80380129)

Co-Investigator(Kenkyū-buntansha) 西良 浩一  徳島大学, 大学院医歯薬学研究部(医学系), 教授 (10304528)
高田 洋一郎  徳島大学, 大学院医歯薬学研究部(医学系), 特任講師 (20420549)
森本 雅俊  徳島大学, 病院, 医員 (20748701)
福井 義浩  徳島大学, 大学院医歯薬学研究部(医学系), 教授 (50144168)
酒井 紀典  徳島大学, 大学院医歯薬学研究部(医学系), 准教授 (80403731)
Project Period (FY) 2015-04-01 – 2018-03-31
Project Status Completed (Fiscal Year 2017)
Budget Amount *help
¥4,940,000 (Direct Cost: ¥3,800,000、Indirect Cost: ¥1,140,000)
Fiscal Year 2017: ¥260,000 (Direct Cost: ¥200,000、Indirect Cost: ¥60,000)
Fiscal Year 2016: ¥780,000 (Direct Cost: ¥600,000、Indirect Cost: ¥180,000)
Fiscal Year 2015: ¥3,900,000 (Direct Cost: ¥3,000,000、Indirect Cost: ¥900,000)
Keywordspedicle screw / biomechanics / re-directed screw / thoracolumbar spine / pullout strength / 生体力学 / 脊椎 / インプラント / 手術 / 未固定遺体 / 脊椎固定術 / 有限要素モデル / 脊椎手術 / 脊椎脊髄病学 / 有限要素法
Outline of Final Research Achievements

Screw malposition is one of the main pitfalls of inserting pedicle screws. Intraoperatively a malpositioned screw is re-directed and inserted along the correct axis. To evaluate the pullout strength of redirected pedicle screws with a larger diameter following lateral wall breach, redirected pedicle screws of the same diameter following medial wall breach, and redirected pedicle screws with a larger diameter following medial wall breach. The pullout strength of re-directed pedicle screws after either a lateral pedicle breach or medial pedicle breach is significantly less than the pullout strength of correctly aligned screw. Redirected pedicle screws of larger diameter after a lateral or medial pedicle breach show recovery of pullout strength.

Report

(4 results)
  • 2017 Annual Research Report   Final Research Report ( PDF )
  • 2016 Research-status Report
  • 2015 Research-status Report
  • Research Products

    (3 results)

All 2018 2016

All Journal Article (2 results) (of which Int'l Joint Research: 1 results,  Peer Reviewed: 2 results) Presentation (1 results)

  • [Journal Article] Pullout Strength of Pedicle Screws Following Redirection After Lateral or Medial Wall Breach.2018

    • Author(s)
      Maeda T, Higashino K, Manabe H, Yamashita K, Hayashi F, Goda Y, Tsuruo Y, Sairyo K.
    • Journal Title

      Spine (Phila Pa 1976). 2018 Feb 21.

      Volume: ‐ Issue: 17 Pages: E983-E989

    • DOI

      10.1097/brs.0000000000002611

    • Related Report
      2017 Annual Research Report
    • Peer Reviewed
  • [Journal Article] The Pullout Strength of Pedicle Screws Following Redirection After Lateral Wall Breach or End-Plate Breach2016

    • Author(s)
      Yuichiro Goda, Kosaku Higashino, Shunichi Toki, Daisuke Suzuki, Takuma Kobayashi, Tetsuya Matsuura, Mineko Fujimiya, Williams C. Hutton, Yoshihiro Fukui, Koichi Sairyo
    • Journal Title

      Spine

      Volume: 41 Issue: 15 Pages: 1218-1223

    • DOI

      10.1097/brs.0000000000001600

    • Related Report
      2016 Research-status Report
    • Peer Reviewed / Int'l Joint Research
  • [Presentation] 脊椎椎弓根スクリュー外側または内側誤挿入後、スクリュー径を増大したスクリューを再挿入した際の強度解析2018

    • Author(s)
      前田徹 東野恒作 眞鍋裕昭 山下一太 林二三男 合田有一郎 鶴尾吉宏 西良浩一
    • Organizer
      第47回日本脊椎脊髄病学会学術集会
    • Related Report
      2017 Annual Research Report

URL: 

Published: 2015-04-16   Modified: 2019-03-29  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI