• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Development of High Resolution Homogeneous Calorimeter Using Liquid Xenon

Research Project

Project/Area Number 16340064
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section一般
Research Field Particle/Nuclear/Cosmic ray/Astro physics
Research InstitutionThe University of Tokyo

Principal Investigator

MORI Toshinori  The University of Tokyo, International Center for Elementary Particle Physics, Professor, 素粒子物理国際研究センター, 教授 (90220011)

Co-Investigator(Kenkyū-buntansha) HARUYAMA Tomiyoshi  High Energy Accelerator Research Organization, Institute of Particle and Nuclear Studies, Professor, 素粒子原子核研究所, 教授 (90181031)
TERASAWA Kazuhiro  WASEDA University, Advanced Research Institute for Science and Engineering, Lecturer, 理工学総合研究センター, 講師 (10329138)
Project Period (FY) 2004 – 2005
Project Status Completed (Fiscal Year 2005)
Budget Amount *help
¥16,400,000 (Direct Cost: ¥16,400,000)
Fiscal Year 2005: ¥4,500,000 (Direct Cost: ¥4,500,000)
Fiscal Year 2004: ¥11,900,000 (Direct Cost: ¥11,900,000)
KeywordsElementary particle physics / calorimeter / Highly pure xenon / International collaboration / photomultiplier / 液体キセノン / 全吸収型カロリメータ / パルス管冷凍機 / 液相純化 / 極低温液体ポンプ / 高速フラッシュADコンバータ / スイス
Research Abstract

In this scientific research project we have developed high resolution homogeneous calorimeter using liquid xenon.
This new type of calorimeter uses liquid xenon as the active medium that emits UV scintillation lights upon incidence of gamma rays and electrons. A number of photomultiplier tubes (PMTs) surrounding the liquid xenon measure these scintillation lights. The calorimeter does not contain any passive material like electrodes in the liquid xenon volume, thus can fully observe all the energy deposits.
We mostly concentrated on developments of various technologies necessary to realize a large volume (an order of 1,000 liters or 3 tons) detector.
Liquid xenon as the detector medium is guaranteed to be perfectly uniform, however, some impurity contamination, if it exists, absorbs the scintillation light and could deteriorate the performance of such a large volume device. We successfully developed a new, efficient purification method to remove impurities very quickly by circulating liqu … More id xenon through molecular sieves using a cryogenic centrifugal liquid pump. We also developed methods and techniques for xenon transfer, xenon pressure/temperature control, safety precaution, etc. These are necessary for practical application of a large volume liquid xenon detector.
We examined the performance of a liquid xenon detector by using π^0 decays. In this test we collected waveform data of PMTs and proved that we can distinguish incident gamma-rays from alpha particles. We also succeeded in developing a new type of PMTs with photocathode and base circuit that can sustain very high background rates even at low temperatures. Computer codes were developed to simulate the detector response and were shown to agree very well with the observed data.
An avalanche photodiode (APD) was operated and tested in liquid xenon. The APD is very compact and has a very high quantum efficiency. The success of this test opened up extensive future applications such as monitoring of absorption length. Less

Report

(3 results)
  • 2005 Annual Research Report   Final Research Report Summary
  • 2004 Annual Research Report
  • Research Products

    (15 results)

All 2006 2005 2004 Other

All Journal Article (15 results)

  • [Journal Article] Development of a Method for Liquid Xenon Purfiction Using a Cryogenic Centrifugal Pump2006

    • Author(s)
      S.Mihara, T.Haruyama, T.Terasawa, T.Mori, 他
    • Journal Title

      Cryogenics 発行予定

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2005 Final Research Report Summary
  • [Journal Article] Absorption of Scintillation Light in a 100L Liquid Xenonγ Ray Detector and Expected Detector Performance2005

    • Author(s)
      T.Haruyama, K.Terasawa, T.Mori, K.Ozone, 他
    • Journal Title

      Nuclear Instruments and Methods A 545

      Pages: 753-764

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2005 Final Research Report Summary
  • [Journal Article] 低温液体用遠心ポンプを用いた液体キセノンの超高純度純化方法の開発2005

    • Author(s)
      三原智, 春山富義, 寺沢和洋, 真木晶弘, 森俊則, 他
    • Journal Title

      低温工学 40・12

      Pages: 525-525

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2005 Final Research Report Summary
  • [Journal Article] Progress of xenon liquefaction technology by using a pulse tube cryocooler2005

    • Author(s)
      T.Haruyama
    • Journal Title

      KEK Preprint 96

      Pages: 1-1

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2005 Final Research Report Summary
  • [Journal Article] LN_2-Free Operation of the MEG Liquid Xenon Calorimeter by Using a High-Power Pulse Tube Cryocooler2005

    • Author(s)
      T.Haruyama, T.Mori, 他
    • Journal Title

      KEK Preprint 64

      Pages: 1-1

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2005 Final Research Report Summary
  • [Journal Article] Absorption of Scintillation Light in a 100L Liquid Xenon γRay Detector and Expected Detector Performance2005

    • Author(s)
      T.Haruyama, K.Terasawa, T.Mori, K.Ozone, et al.
    • Journal Title

      Nuclear Instruments and Methods A vol 545

      Pages: 753-764

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2005 Final Research Report Summary
  • [Journal Article] Development of a Method for Liquid Xenon Purification Using a Cryogenic Centrifugal Pump2005

    • Author(s)
      S.Mihara, T.Haruyama, K.Terasawa, A.Maki, T.Mori, et al.
    • Journal Title

      Teion Kogaku vol.40-12

      Pages: 525-525

    • NAID

      10016728876

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2005 Final Research Report Summary
  • [Journal Article] Progress of xenon liquefaction technology by using a pulse tube cryocooler2005

    • Author(s)
      T.Haruyama
    • Journal Title

      KEK Preprint vol 96

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2005 Final Research Report Summary
  • [Journal Article] LN_2 Free Operation of the MEG Liquid Xenon Calorimeter by Using a High-power Pulse Tube Cryocooler2005

    • Author(s)
      T.Haruyama, T.Mori et al.
    • Journal Title

      KEK Preprint vol 64

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2005 Final Research Report Summary
  • [Journal Article] 低温液体循環ポンプを用いた液体キセノン純化方法の開発2005

    • Author(s)
      三原智, 春山富義, 寺沢和洋, 真木晶弘, 森俊則 他
    • Journal Title

      低温工学 40・12

      Pages: 525-525

    • Related Report
      2005 Annual Research Report
  • [Journal Article] Absorption of Scintillation Light in a 100L Liquid Xenon γ Ray Detector and Expected Detector Performance2005

    • Author(s)
      K.Ozone他
    • Journal Title

      Nuclear Instruments and Methods A (発表予定)

    • Related Report
      2004 Annual Research Report
  • [Journal Article] Development of a liquid-xenon photon detector towards the search for a muon rare decay mode at Paul Scherrer Institute2004

    • Author(s)
      S.Mihara, T.Hruyama, K.Terasawa, T.Mori, 他
    • Journal Title

      Cryogenics 44

      Pages: 223-228

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2005 Final Research Report Summary
  • [Journal Article] Development of a liquid-xenon photon detector towards the search for a muon rare decay mode at Paul Scherrer Institute2004

    • Author(s)
      S.Mihara, T.Haruyama, K.Terasawa, T.Mori et al.
    • Journal Title

      Cryogenics vol.44

      Pages: 223-228

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2005 Final Research Report Summary
  • [Journal Article] Development of a liquid-xenon photon detector towards the search for a muon rare decay mode at Paul Scherrer Institute2004

    • Author(s)
      S.Mihara他
    • Journal Title

      Cryogenics 44

      Pages: 223-228

    • Related Report
      2004 Annual Research Report
  • [Journal Article] Development of a Method for Liquid Xenon Purification Using a Cryogenic Centrifugal Pump

    • Author(s)
      S.Mihara, T.Haruyama, K.Terasawa, A.Maki, T.Mori, et al.
    • Journal Title

      Cryogenics (in press)

    • NAID

      10016728876

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2005 Final Research Report Summary

URL: 

Published: 2004-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi