• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Study of detector measuring distal shape and position using range scanner in proton therapy

Research Project

Project/Area Number 16591183
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionUniversity of Tsukuba

Principal Investigator

YASUOKA Kiyoshi  University of Tsukuba, Graduate School of Comprehensive Human Sciences, Assistant Professor (50200499)

Project Period (FY) 2004 – 2006
Project Status Completed (Fiscal Year 2007)
Budget Amount *help
¥3,700,000 (Direct Cost: ¥3,700,000)
Fiscal Year 2006: ¥300,000 (Direct Cost: ¥300,000)
Fiscal Year 2005: ¥700,000 (Direct Cost: ¥700,000)
Fiscal Year 2004: ¥2,700,000 (Direct Cost: ¥2,700,000)
Keywordsproton therapy / CCD camera / scintillator / dose distribution / measure depth
Research Abstract

Using a plastic scintillating plate, a CCD camera, and a wedge-type range shifter(WRS), we produced a distal-shaped and distal-position detector capable of measuring depth dose distribution in range-scanning technique. At the 2^<nd> exposure room in the proton medical research center (PMRC), University of Tsukuba, we took basic data concerned with characteristics of dose profiles in the proton beam. Measuring charges recorded on the dose monitors (M1 and M2) in the proton beam line, charges on the reference dose meter (M3) setup on the isocenter, and charges on the CCD elements viewing the scintillating plate (SciCCD) just behind M3, we compared the depth dose distributions obtained by SciCCD to those done by the reference M3. They revealed a quenching effect; 15% light-yield reduction at maximum at the Bragg peak and in the high LET regions of 20-mm measured from the distal edge. This effect was confirmed as well as in the regions of the 50-mm width SOBP and the depth dose distribution produced with the bolus and collimator. In the comparison among the depth dose distributions obtained using SciCCD and M3 detectors, and calculated with the pencil beam algorithm (PBA) in the treatment planning program, we revealed difference in detailed shapes of the distribution and importance of more accurate positioning methods as well as correction of quenching effects. Installing an automatic control system to the WRS system is expected to improve data taking speeds and to provide various kinds of dose distribution. The scintillating plate and the CCD camera were applied to the isocenter verification system at PMRC. This system improved measurement time to 30-min, the one-forth of the conventional method, without degradation in accuracy of ±0.1 mm.

Report

(4 results)
  • 2007 Final Research Report Summary
  • 2006 Annual Research Report
  • 2005 Annual Research Report
  • 2004 Annual Research Report
  • Research Products

    (6 results)

All 2006

All Journal Article (6 results)

  • [Journal Article] PMRCにおけるシンチレータ板、CCDカメラ、楔形レンジ変調器を用いた線量分布確認システムについて2006

    • Author(s)
      安岡聖
    • Journal Title

      Japanese Journal of Medical Physics 26・spl. 2

      Pages: 251-252

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Journal Article] シンチレータとCCDカメラを用いたアイソセンター確認システムの精度評価2006

    • Author(s)
      安岡聖
    • Journal Title

      Japanese Journal of Medical Physics 28・spl. 3

      Pages: 109-110

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Journal Article] A quick system of dose distribution confirmation using a plastic scintillating plate, a CCD camera, and a wedge-type range shifter at PMRC.2006

    • Author(s)
      Yasuoka K.
    • Journal Title

      Japanese Journal of Medical Physics Vol. 26(2)

      Pages: 251-252

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Journal Article] Estimation of accuracy in an isocenter verification system usinj scintillating plate and CCD camera.2006

    • Author(s)
      Yasuoka K.
    • Journal Title

      Japanese Journal of Medical Physics Vol. 26(3)

      Pages: 109-110

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Journal Article] PMCRにおけるシンチレ-タ板、CCDカメラ、楔形レンジ変調器を用いた線量分布確認システムについて2006

    • Author(s)
      安岡 聖
    • Journal Title

      Japanese Journal of Medical Physics 26.spl.2

      Pages: 251-252

    • Related Report
      2006 Annual Research Report
  • [Journal Article] シンチレータとCCDカメラを用いたアイソセンタ-確認システムの精度評価2006

    • Author(s)
      安岡 聖
    • Journal Title

      Japanese Journal of Medical Physics 28.spl.3

      Pages: 109-110

    • Related Report
      2006 Annual Research Report

URL: 

Published: 2004-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi