It is found that volume of vapor bubble under non-uniform magnetic field decrease with increase of magnetic field intensity by both ways of electromagnetic induction method and optical visualization using a near infrared ray. Numerical simulation revealed that surface tension and magnetic buoyancy are dominant for bubble detachmentBy applying non-uniform magnetic field to the heater surface, the heat transfer enhanced up to 13 % in fully developed nucleate boiling region. It is possible to actively control of boiling heat transfer by applying non-uniform magnetic field.
All 2017 2016
All Journal Article (1 results) (of which Peer Reviewed: 1 results, Open Access: 1 results) Presentation (5 results) (of which Int'l Joint Research: 4 results, Invited: 1 results)
Journal of Magnetism and Magnetic Materials
Volume: 431 Pages: 164-168