Development of process spectroscopy tomography method for diagnosis of lymphedema
Project/Area Number |
16J08769
|
Research Category |
Grant-in-Aid for JSPS Fellows
|
Allocation Type | Single-year Grants |
Section | 国内 |
Research Field |
Fluid engineering
|
Research Institution | Chiba University |
Principal Investigator |
バイディラ ラマダン マルリン 千葉大学, 工学研究科, 特別研究員(DC2)
|
Project Period (FY) |
2016-04-22 – 2018-03-31
|
Project Status |
Completed (Fiscal Year 2017)
|
Budget Amount *help |
¥2,300,000 (Direct Cost: ¥2,300,000)
Fiscal Year 2017: ¥1,100,000 (Direct Cost: ¥1,100,000)
Fiscal Year 2016: ¥1,200,000 (Direct Cost: ¥1,200,000)
|
Keywords | Lymphedema diagnostic / electrical tomography / adjustable diameter / Lymphedema / Upper Arm Imaging / EIST / ECT |
Outline of Annual Research Achievements |
Research results 29年4月~30年3月 1.A permittivity range of biological tissue is very high and cannot covered by the current capacitance measurement system. In order to allow electrical capacitance tomography can visualize the pathology and physiological condition inside human body, a new scanning method is proposed based on four-electrodes measurement in low-voltage and low-frequency capacitance measurement. 2.The patient’s upper arm have different diameter condition among Lymphedema stages. The aim of this research is to develop an adjustable EIT sensor, which can be adjustable diameter of the sensor within a certain range therefore the electrode gap-to-diameter ratio (EDR) of the sensor is changed. A prototype EIT sensor with adjustable diameter and consists of 32 electrodes is manufactured and evaluated through experimental studies. The experimental results show that the EIT sensor with adjustable diameter can provide similar reconstructed images to a traditional EIT sensor which has a fixed diameter. 3.The acquisition measurement system based on FPGA and 32 electrodes attached to active electrodes circuit has been developed to establish a simultaneously dielectric dispersion measurement within 928 measurement pairs. 4.The clinical study with volunteer of Lymphedema could not be conducted during April 2017 to March 2018 due technical problem in data acquisition system. During this time, a prototype system was evaluated based on phantom objects and volunteers with normal condition. The research results of volunteers with normal condition are not published yet.
|
Research Progress Status |
29年度が最終年度であるため、記入しない。
|
Strategy for Future Research Activity |
29年度が最終年度であるため、記入しない。
|