Development of the new rod for spinal instrumentation for reducing its loosening risks based on mechanical validation
Project/Area Number |
16K05993
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Multi-year Fund |
Section | 一般 |
Research Field |
Materials/Mechanics of materials
|
Research Institution | Ryukoku University |
Principal Investigator |
|
Co-Investigator(Kenkyū-buntansha) |
村上 英樹 名古屋市立大学, 整形外科, 教授 (70334779)
辻上 哲也 龍谷大学, 理工学部, 教授 (80243179)
|
Project Period (FY) |
2016-04-01 – 2019-03-31
|
Project Status |
Completed (Fiscal Year 2018)
|
Budget Amount *help |
¥4,810,000 (Direct Cost: ¥3,700,000、Indirect Cost: ¥1,110,000)
Fiscal Year 2018: ¥780,000 (Direct Cost: ¥600,000、Indirect Cost: ¥180,000)
Fiscal Year 2017: ¥1,820,000 (Direct Cost: ¥1,400,000、Indirect Cost: ¥420,000)
Fiscal Year 2016: ¥2,210,000 (Direct Cost: ¥1,700,000、Indirect Cost: ¥510,000)
|
Keywords | 計算バイオメカニクス / 脊椎固定術 / スクリュー緩み / 有限要素法 / 骨リモデリング / 繰り返し負荷 / 引き抜き試験 / 微小破壊 / 空孔分析 / 破壊 / 緩み / 椎体 / 後方固定術 / 接触解析 / 脊椎 / 機械材料・材料力学 / リモデリング |
Outline of Final Research Achievements |
In order to evaluate potency of the proposed dynamic rod to suppress loosening risk of screw for spinal instrumentation in osteoporosis, we performed bone remodeling simulation around screw, computational pulling-test of screw, CT-based nonlinear fracture analyses around screw, and experimental pulling-test of screws after applying cyclic loads for spinal instrumentation model using artificial bone model. As results, first, trabecular network was dense and equably around the screw in the dynamic fixation with high reaction force to the pulling of screw, while sparse in a rigid rod. Second, the dynamic rod suppressed more failure elements under any loading conditions, especially under the rotation conditions. Third, experimental reaction force of screw was low for the rigid rod, while high for the dynamic rod with suppression of the microfracture around screw. These results indicated that the proposed dynamic rod was effective to reduce loosening risk of screw.
|
Academic Significance and Societal Importance of the Research Achievements |
本研究成果は,スクリューのゆるみ抑制効果が高い新たな手術方法として,国内における脊椎固定術に対して新しい知見を提示する.1,000万人の骨粗鬆症患者がいる国内における緩みの危険性を抑制可能なロッドの適用の推進は,整形外科治療に大きなインパクトをもたらし,高い社会貢献につながる. また,ロッドのオーダーメイド設計や,他の固定術法の安全性評価に関する新たな研究の萌芽につながることや,骨の力学的適応メカニズムの理解に加え,適応構造物の開発への発展も期待される.
|
Report
(4 results)
Research Products
(28 results)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
[Presentation] 骨粗鬆症性椎体骨折に対するdynamic stabilizationを用いた脊椎固定術が椎体に及ぼす影響-有限要素モデルを用いた応力解析-2016
Author(s)
藤井衛之, 村上英樹, 出村諭, 加藤仁志, 吉岡克人, 五十嵐峻, 米澤則隆, 高橋直樹, 土屋弘行, 田原大輔, 両角有里, 松本悠希
Organizer
第45回日本脊椎脊髄病学会
Place of Presentation
幕張メッセ 国際会議場
Year and Date
2016-04-14
Related Report
-
-
-
-
-