• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Multimodal imaging of cancerous regions utilizing spectral X-ray CT and 7T-MRI

Research Project

Project/Area Number 17K01424
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeMulti-year Fund
Section一般
Research Field Medical systems
Research InstitutionToho University

Principal Investigator

Watanabe Manabu  東邦大学, 医学部, 教授 (30297709)

Project Period (FY) 2017-04-01 – 2020-03-31
Project Status Completed (Fiscal Year 2019)
Budget Amount *help
¥4,680,000 (Direct Cost: ¥3,600,000、Indirect Cost: ¥1,080,000)
Fiscal Year 2019: ¥1,430,000 (Direct Cost: ¥1,100,000、Indirect Cost: ¥330,000)
Fiscal Year 2018: ¥1,430,000 (Direct Cost: ¥1,100,000、Indirect Cost: ¥330,000)
Fiscal Year 2017: ¥1,820,000 (Direct Cost: ¥1,400,000、Indirect Cost: ¥420,000)
KeywordsX線CT / CdTe検出器 / フォトンカウンティング / CdTeアレー / スペクトラルCT / 7T-MRI / ナノ粒子懸濁液 / 陰性造影剤 / スペクトラルX線CT / トリプルエネルギーCT / ビームハードニングCT / 3次元イメージング / ブドウ糖 / ガドペント酸メグルミン / 酸化ガドリニウム / T2強調画像 / トリプルエネルギーCTスキャナー / クアッドエネルギーCT / KエッジCT / マルチモーダルイメージング / エネルギー弁別X線CT / Gd-KエッジCT / 画像診断システム
Outline of Final Research Achievements

To visualize cancerous region utilizing enhanced K-edge angiography using I and Gd media, we developed both the first- and third-generation X-ray spectral CT (SP-CT) scanners. The spatial resolutions of the first and third scanners were 0.25 and 0.1mm, respectively, and fine blood vessels were observed at high contrasts.
Using 7T-MRI and T2*WI, we carried out cancer-region visualization using Gd2O3-nanoperticle suspension. The nanoparticles remained effectively in the rabbit-thigh cancer utilizing femoral-vein injection, and the gray-value density in the cancer substantially decreased. In the infusion of the nanoparticle suspension from a rabbit ear, a negative contrast effect in the cancerous region was observed immediately after the infusion.

Academic Significance and Societal Importance of the Research Achievements

本研究ではフォトンカウンティングを利用したスペクトラルX線CTと7T-MRIの医療診断における先端技術を取り入れて,さらに新しい技術の開発を試みた。第1世代CTではデュアル,トリプル,クアッドエネルギーのスキャナーが開発され,撮影エネルギー範囲を変化させることにより,血管のコントラストが著しく変化した。第3世代では空間分解能が0.1mm程度まで改善され,3D-CTも実現された。一方,7T-MRIでは陰性造影剤としての酸化ガドリニウムナノ粒子懸濁液が開発され,造影効果が確認された。磁性ナノ粒子はハイパーサーミアにも利用できることから,癌治療への応用も期待される。

Report

(4 results)
  • 2019 Annual Research Report   Final Research Report ( PDF )
  • 2018 Research-status Report
  • 2017 Research-status Report
  • Research Products

    (52 results)

All 2020 2019 2018 2017

All Journal Article (30 results) (of which Int'l Joint Research: 7 results,  Peer Reviewed: 13 results,  Open Access: 1 results) Presentation (22 results) (of which Int'l Joint Research: 13 results)

  • [Journal Article] Triple-sensitivity high-spatial-resolution X-ray computed tomography using a cadmium-telluride detector and its beam-hardening effect2020

    • Author(s)
      Yoshida, S., Sato, E., Oda, Y., Yoshioka, K., Moriyama, H., Watanabe, M.
    • Journal Title

      Appl. Radiat. Isot.

      Volume: 159 Pages: 109089-109089

    • DOI

      10.1016/j.apradiso.2020.109089

    • Related Report
      2019 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Near-infrared-ray computed tomography with 850-nm peak and high spatial resplutions in first living-body window2019

    • Author(s)
      Sato, E., Yoshida, A., Someya. T., Oda, Y., Yoshida, S., Yoshioka, K., Sato, Y., Moriyama, H., Watanabe, M.
    • Journal Title

      Phys. Open

      Volume: 2 Pages: 100010-100010

    • DOI

      10.1016/j.physo.2019.100010

    • Related Report
      2019 Annual Research Report
    • Peer Reviewed / Open Access
  • [Journal Article] Near-infrared-ray computed tomography with 850-nm peak and high spatial resolutions2019

    • Author(s)
      Sato, E., Yoshida, A., Someya. T., Yoshizawa, T., Morimoto, M., Mine, T., Oda, Y., Yoshida, S., Yoshioka, K., Sato, Y.
    • Journal Title

      Ann. Rep. Iwate Med. Univ. Center Lib. Arts Sci.

      Volume: 54 Pages: 1-8

    • Related Report
      2019 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Measurement of penetrating photon spectra using a white power light-emitting diode2019

    • Author(s)
      Sato, E., Oda, Y., Yoshida, S., Yoshioka, K., Moriyama, H., Hagiwara, O., Enomoto, T., Watanabe, M.
    • Journal Title

      Ann. Rep. Iwate Med. Univ. Center Lib. Arts Sci.

      Volume: 54 Pages: 9-12

    • NAID

      120006777463

    • Related Report
      2019 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Investigation of low-dose energy-dispersive x-ray computed tomography utilizing beam hardening2019

    • Author(s)
      Yoshida, S., Sato, E., Oda, Y., Yoshioka, S., Ehara, S., Moriyama, H., Hagiwara, O., Enomoto, T., Watanabe, M.
    • Journal Title

      Proc. SPIE

      Volume: 11114 Pages: 55-55

    • DOI

      10.1117/12.2529663

    • Related Report
      2019 Annual Research Report
    • Int'l Joint Research
  • [Journal Article] Intense nickel-K-photon irradiation from weakly-ionized linear plasma x-ray source with a reflector2019

    • Author(s)
      Sato, E., Sato, Y., Yoshida, S., Yoshioka, K., Moriyama, H., Watanabe, M.
    • Journal Title

      Proc. SPIE

      Volume: 11114 Pages: 52-52

    • DOI

      10.1117/12.2526546

    • Related Report
      2019 Annual Research Report
    • Int'l Joint Research
  • [Journal Article] Photon-counting x-ray computed tomography using a YAP(Ce)-PMT detector and beam hardening2019

    • Author(s)
      Watanabe, M., Sato, E., Yoshida, S., Yoshioka, K., Oda, Y., Moriyama, H., Hagiwara, O., Enomoto, T.
    • Journal Title

      Proc. SPIE

      Volume: 11114 Pages: 51-51

    • DOI

      10.1117/12.2530767

    • Related Report
      2019 Annual Research Report
    • Int'l Joint Research
  • [Journal Article] Measurement of humanbody-window spectra using a white power light-emitting diode and its application to high-spatial-resolution computed tomography2019

    • Author(s)
      Moriyama, H., Sato, E., Oda, Y., Yoshida, S., Hagiwara, O., Enomoto, T., Watanabe, M.
    • Journal Title

      Proc. SPIE

      Volume: 11073 Pages: 74-74

    • DOI

      10.1117/12.2527720

    • Related Report
      2019 Annual Research Report
    • Int'l Joint Research
  • [Journal Article] 850-nm near-infrared-ray computed tomography with high spatial resolutions2019

    • Author(s)
      Sato, E., Oda, Y., Sato, Y., Yoshida, S., Moriyama, H., Watanabe, M.
    • Journal Title

      Proc. SPIE

      Volume: 11073 Pages: 22-22

    • DOI

      10.1117/12.2526543

    • Related Report
      2019 Annual Research Report
    • Int'l Joint Research
  • [Journal Article] High-speed dual-energy x-ray photoncounter using a YAP(Ce)-photomultiplier detector and itsapplication to low-dose computedtomography2019

    • Author(s)
      Sato, Y., Sato, E., Oda, Y., Moriyama, H., Hagiwara, O., Matsukiyo, H., Enomoto, T., Watanabe, M., Kusachi, S.
    • Journal Title

      Proc. SPIE

      Volume: 11051 Pages: 19-19

    • DOI

      10.1117/12.2524632

    • Related Report
      2019 Annual Research Report
    • Int'l Joint Research
  • [Journal Article] Low-dose low-scattering X-ray computed tomography with high-spatial-energy resolutions using a cooled cadmium telluride detector2019

    • Author(s)
      Moriyama Hodaka、Watanabe Manabu、Kusachi Shinya、Oda Yasuyuki、Sato Eiichi
    • Journal Title

      Ultramicroscopy

      Volume: 199 Pages: 62-69

    • DOI

      10.1016/j.ultramic.2019.01.014

    • Related Report
      2018 Research-status Report
    • Peer Reviewed
  • [Journal Article] Dual-energy x-ray computed tomography scanner using a room-temperature cadmium-telluride detector and a range-region counter2018

    • Author(s)
      8)Watanabe, M., Sato, E., Oda, Y., Yoshida, S., Moriyama, H., Hagiwara, O., Matsukiyo, H., Enomoto, T., Kusachi, S.
    • Journal Title

      SPIE 10763

      Volume: 10763 Pages: 1-1

    • DOI

      10.1117/12.2323756

    • Related Report
      2019 Annual Research Report 2018 Research-status Report
    • Int'l Joint Research
  • [Journal Article] Zero-dark-counting brief measurement of X-ray spectra using a lutetium-oxyorthosilicate multipixel-photon detector driven in pre-Geiger mode.2018

    • Author(s)
      Enomoto, T., Sato, E., Moriyama, H., Hagiwara, O., Matsukiyo, H., Watanabe, M., Kusachi, S.
    • Journal Title

      Int. J. Sci. Res

      Volume: 7 Pages: 1751-1756

    • Related Report
      2018 Research-status Report
    • Peer Reviewed
  • [Journal Article] Dual-energy low-dose X-ray computed tomography scanner using a room-temperature cadmium telluride detector.2018

    • Author(s)
      Watanabe, M., Sato, E., Moriyama, H., Hagiwara, O., Matsukiyo, H., Enomoto, T., Kusachi, S.
    • Journal Title

      Int. J. Sci. Res.

      Volume: 7 Pages: 184-189

    • Related Report
      2018 Research-status Report
    • Peer Reviewed
  • [Journal Article] Enhanced K-Edge Radiography Using a High-Spatial-Resolution Cadmium Telluride Array Detector2018

    • Author(s)
      Watanabe Manabu、Sato Eiichi、Oda Yasuyuki、Moriyama Hodaka、Hagiwara Osahiko、Matsukiyo Hiroshi、Enomoto Toshiyuki、Kusachi Shinya
    • Journal Title

      International Journal of Medical Physics, Clinical Engineering and Radiation Oncology

      Volume: 07 Issue: 03 Pages: 296-307

    • DOI

      10.4236/ijmpcero.2018.73024

    • Related Report
      2018 Research-status Report
    • Peer Reviewed
  • [Journal Article] Triple-energy high-count-rate x-ray computed tomography scanner using a cooled cadmium-telluride detector2018

    • Author(s)
      Moriyama Hodaka、Oda Yasuyuki、Sato Yuichi、Yoshida Sohei、Yamaguchi Satoshi、Hagiwara Osahiko、Matsukiyo Hiroshi、Enomoto Toshiyuki、Watanabe Manabu、Kusachi Shinya、Sato Eiichi
    • Journal Title

      SPIE 10763

      Volume: 10763 Pages: 16-16

    • DOI

      10.1117/12.2320172

    • Related Report
      2018 Research-status Report
  • [Journal Article] Dual-energy high-count-rate x-ray computed tomography using a cerium-doped yttrium-aluminum-perovskite crystal and a photomultiplier tube2018

    • Author(s)
      Sato Eiichi、Oda Yasuyuki、Yoshida Sohei、Yamaguchi Satoshi、Sato Yuichi、Hagiwara Osahiko、Matsukiyo Hiroshi、Enomoto Toshiyuki、Watanabe Manabu、Kusachi Shinya、Morioyama Hodaka
    • Journal Title

      SPIE 10763

      Volume: 10763 Pages: 18-18

    • DOI

      10.1117/12.2320174

    • Related Report
      2018 Research-status Report
  • [Journal Article] Development of an amplifier module for measuring X-ray spectra using a photomultiplier tube.2018

    • Author(s)
      Sato, E., Oda, Y., Sagae, M., Yoshida, S., Yamaguchi, S., Sato, Y., Moriyama, H., Hagiwara, O., Matsukiyo, H., Enomoto, T., Watanabe, M., Kusachi, S.
    • Journal Title

      Ann. Rep. Iwate Med. Univ. Center Lib. Arts Sci.

      Volume: 53 Pages: 1-6

    • NAID

      120006548773

    • Related Report
      2018 Research-status Report
  • [Journal Article] High-sensitivity compact dosimeter using two silicon X-ray diode.2018

    • Author(s)
      Sato, E., Oda, Y., Sagae, M., Yoshida, S., Yamaguchi, S., Sato, Y., Moriyama, H., Hagiwara, O., Matsukiyo, H., Enomoto, T., Watanabe, M., Kusachi, S.
    • Journal Title

      Ann. Rep. Iwate Med. Univ. Center Lib. Arts Sci.

      Volume: 53 Pages: 7-12

    • NAID

      120006548774

    • Related Report
      2018 Research-status Report
  • [Journal Article] Dual-energy high-count-rate X-ray computed tomography scanner using a cerium-doped yttrium aluminum perovskite crystal and a small-photomultiplier tube2018

    • Author(s)
      Sato Tsukuru、Sato Eiichi、Oda Yasuyuki、Sato Yuichi、Yamaguchi Satoshi、Hagiwara Osahiko、Yoshida Sohei、Matsukiyo Hiroshi、Enomoto Toshiyuki、Watanabe Manabu、Kusachi Shinya
    • Journal Title

      Health and Technology

      Volume: - Issue: 3 Pages: 179-187

    • DOI

      10.1007/s12553-018-0234-6

    • Related Report
      2017 Research-status Report
  • [Journal Article] Triple-energy high-count-rate X-ray computed tomography scanner using a cadmium telluride detector2018

    • Author(s)
      Sato Eiichi、Sato Tsukuru、Oda Yasuyuki、Sato Yuichi、Yoshida Sohei、Yamaguchi Satoshi、Hagiwara Osahiko、Matsukiyo Hiroshi、Enomoto Toshiyuki、Watanabe Manabu、Kusachi Shinya
    • Journal Title

      Health and Technology

      Volume: - Issue: 3 Pages: 197-203

    • DOI

      10.1007/s12553-018-0236-4

    • Related Report
      2017 Research-status Report
  • [Journal Article] 850-nm-peak high-sensitivity near-infrared-ray computed tomography scanner in the living-body window2018

    • Author(s)
      Sato Yuichi、Takaoka Akiko、Sato Tsukuru、Sato Eiichi、Oda Yasuyuki、Yoshida Sohei、Moriyama Hodaka、Hagiwara Osahiko、Matsukiyo Hiroshi、Enomoto Toshiyuki、Watanabe Manabu、Kusachi Shinya
    • Journal Title

      Health and Technology

      Volume: - Issue: 3 Pages: 205-210

    • DOI

      10.1007/s12553-018-0237-3

    • Related Report
      2017 Research-status Report
    • Peer Reviewed
  • [Journal Article] Investigation of dual-energy X-ray photon counting using a cadmium telluride detector with dual-energy selection electronics2017

    • Author(s)
      Sato Eiichi、Kosuge Yoshiyuki、Yamanome Hayato、Mikata Akiko、Miura Tatsuya、Oda Yasuyuki、Ishii Tomotaka、Hagiwara Osahiko、Matsukiyo Hiroshi、Watanabe Manabu、Kusachi Shinya
    • Journal Title

      Radiation Physics and Chemistry

      Volume: 130 Pages: 385-390

    • DOI

      10.1016/j.radphyschem.2016.09.018

    • Related Report
      2017 Research-status Report
    • Peer Reviewed
  • [Journal Article] Investigation of quad-energy high-rate photon counting for X-ray computed tomography using a cadmium telluride detector2017

    • Author(s)
      Matsukiyo Hiroshi、Sato Eiichi、Oda Yasuyuki、Yamaguchi Satoshi、Sato Yuichi、Hagiwara Osahiko、Enomoto Toshiyuki、Watanabe Manabu、Kusachi Shinya
    • Journal Title

      Applied Radiation and Isotopes

      Volume: 130 Pages: 54-59

    • DOI

      10.1016/j.apradiso.2017.09.011

    • Related Report
      2017 Research-status Report
    • Peer Reviewed
  • [Journal Article] Dual-Energy X-Ray Computed Tomography Scanner Using Two Different Energy-Selection Electronics and a Lutetium-Oxyorthosilicate Photomultiplier Detector2017

    • Author(s)
      Hagiwara Osahiko、Sato Eiichi、Oda Yasuyuki、Yamaguchi Satoshi、Sato Yuichi、Matsukiyo Hiroshi、Enomoto Toshiyuki、Watanabe Manabu、Kusachi Shinya
    • Journal Title

      International Journal of Medical Physics, Clinical Engineering and Radiation Oncology

      Volume: 06 Issue: 03 Pages: 266-279

    • DOI

      10.4236/ijmpcero.2017.63024

    • Related Report
      2017 Research-status Report
    • Peer Reviewed
  • [Journal Article] Brief measurement of X-ray spectra using a lutetium-yttrium-oxyorthosilicate crystal and a micro-photomultiplier tube2017

    • Author(s)
      Sato Eiichi、Oda Yasuyuki、Ishii Tomotaka、Hagiwara Osahiko、Matsukiyo Hiroshi、Enomoto Toshiyuki、Watanabe Manabu、Kusachi Shinya
    • Journal Title

      Radiation Measurements

      Volume: 107 Pages: 94-101

    • DOI

      10.1016/j.radmeas.2017.09.007

    • Related Report
      2017 Research-status Report
    • Peer Reviewed
  • [Journal Article] Investigation of a high-sensitivity near-infrared-ray computed tomography scanner2017

    • Author(s)
      Sato Eiichi、Oda Yasuyuki、Sato Yuichi、Yoshida Sohei、Ishii Tomotaka、Hagiwara Osahiko、Matsukiyo Hiroshi、Enomoto Toshiyuki、Watanabe Manabu、Kusachi Shinya、Yamaguchi Satoshi
    • Journal Title

      SPIE

      Volume: 103930U Pages: 1-6

    • DOI

      10.1117/12.2275290

    • Related Report
      2017 Research-status Report
  • [Journal Article] Measurement of x-ray spectra using a recent YAP(Ce)-MPPC detector2017

    • Author(s)
      Sato Eiichi、Oda Yasuyuki、Yoshida Sohei、Yamaguchi Satoshi、Hagiwara Osahiko、Sato Yuichi、Ishii Tomotaka、Matsukiyo Hiroshi、Enomoto Toshiyuki、Watanabe Manabu、Kusachi Shinya
    • Journal Title

      SPIE 10393

      Volume: 103930J Pages: 1-6

    • DOI

      10.1117/12.2275288

    • Related Report
      2017 Research-status Report
  • [Journal Article] Development of a compact dosimeter using a silicon X-ray diode and a long USB cable.2017

    • Author(s)
      Sato E, Oda Y, Sagae M, Yoshida S, Yamaguchi S, Sato Y, Moriyama H, Hagiwara O, Matsukiyo H, Enomoto T, Watanabe M, Kusachi S
    • Journal Title

      Ann. Rep. Iwate Med. Univ. Center Lib. Arts Sci.

      Volume: 51 Pages: 1-5

    • NAID

      120006376610

    • Related Report
      2017 Research-status Report
  • [Journal Article] Measurement of X-ray spectra using a photomultiplier tube in conjunction with a simple inverse amplifier.2017

    • Author(s)
      Sato E, Oda Y, Sagae M, Yoshida S, Yamaguchi S, Sato Y, Moriyama H, Hagiwara O, Matsukiyo H, Enomoto T, Watanabe M, Kusachi S
    • Journal Title

      Ann. Rep. Iwate Med. Univ. Center Lib. Arts Sci.

      Volume: 51 Pages: 7-12

    • NAID

      120006376611

    • Related Report
      2017 Research-status Report
  • [Presentation] Investigation of low-dose energy-dispersive x-ray computed tomography utilizing beam hardening2019

    • Author(s)
      Yoshida, S., Sato, E., Oda, Y., Yoshioka, S., Ehara, S., Moriyama, H., Hagiwara, O., Enomoto, T., Watanabe, M.
    • Organizer
      SPIE Optics+Photonics, San Diego
    • Related Report
      2019 Annual Research Report
  • [Presentation] Intense nickel-K-photon irradiation from weakly-ionized linear plasma x-ray source with a reflector2019

    • Author(s)
      Sato, E., Sato, Y., Yoshida, S., Yoshioka, K., Moriyama, H., Watanabe, M.
    • Organizer
      SPIE Optics+Photonics, San Diego
    • Related Report
      2019 Annual Research Report
  • [Presentation] Photon-counting x-ray computed tomography using a YAP(Ce)-PMT detector and beam hardening2019

    • Author(s)
      Watanabe, M., Sato, E., Yoshida, S., Yoshioka, K., Oda, Y., Moriyama, H., Hagiwara, O., Enomoto, T.
    • Organizer
      SPIE Optics+Photonics, San Diego
    • Related Report
      2019 Annual Research Report
  • [Presentation] 850-nm near-infrared-ray computed tomography with high spatial resolutions2019

    • Author(s)
      Sato, E., Oda, Y., Sato, Y., Yoshida, S., Moriyama, H., Watanabe, M.
    • Organizer
      European Conferences on Biomedical Optics, Munich.
    • Related Report
      2019 Annual Research Report
  • [Presentation] Measurement of human-body-window spectra using a white power light-emitting diode and its application to high-spatial-resolution computed tomography2019

    • Author(s)
      Moriyama, H., Sato, E., Oda, Y., Yoshida, S., Hagiwara, O., Enomoto, T., Watanabe, M.
    • Organizer
      European Conferences on Biomedical Optics, Munich.
    • Related Report
      2019 Annual Research Report
  • [Presentation] 850-nm-peak high-spatial-resolution near-infrared-ray computed tomography in the living-body window.2018

    • Author(s)
      Sato, E. Oda, Y., Sato, Y., Moriyama, H., Hagiwara, O., Matsukiyo, H., Enomoto, T., Watanabe, M., Kusachi, S.
    • Organizer
      Asia-Oceania Congress on Medical Physics
    • Related Report
      2018 Research-status Report
    • Int'l Joint Research
  • [Presentation] Low-dose tripe-energy X-ray computed tomography using a cadmium telluride detector with high-spatial and -energy resolutions.2018

    • Author(s)
      Sato, E. Oda, Y., Sato, Y., Moriyama, H., Hagiwara, O., Matsukiyo, H., Enomoto, T., Watanabe, M., Kusachi, S.
    • Organizer
      Asia-Oceania Congress on Medical Physics
    • Related Report
      2018 Research-status Report
    • Int'l Joint Research
  • [Presentation] Intense nickel-K-photon irradiation from weakly-ionized linear plasma X-ray source with a zinc reflector.2018

    • Author(s)
      Sato, E., Oda, Y., Sato, Y., Morikaya, H., Hagiwara, O., Matsukiyo, H., Enomoto, T., Watanabe, M., Kusachi, S.
    • Organizer
      32nd Int. Congr. High-Speed Imaging and Photonics
    • Related Report
      2018 Research-status Report
    • Int'l Joint Research
  • [Presentation] High-speed tripe-energy X-ray photon counter using a room-temperature cadmium-telluride detector and its application to high-spatial-resolution low-dose computed tomography.2018

    • Author(s)
      Watanabe, M., Sato, E., Oda, Y., Sato, Y., Yamaguchi, S., Moriyama, H., Hagiwara, O., Matsukiyo, H., Enomoto, T., Kusachi, S.
    • Organizer
      32nd Int. Congr. High-Speed Imaging and Photonics
    • Related Report
      2018 Research-status Report
    • Int'l Joint Research
  • [Presentation] High-speed dual-energy X-ray photon counter using a YAP(Ce)-photomultiplier detector and its application to low-dose computed tomography.2018

    • Author(s)
      Sato, Y., Sato, E., Oda, Y., Moriyama, H., Hagiwara, O., Matsukiyo, H., Enomoto, T., Watanabe, M., Kusachi, S.
    • Organizer
      32nd Int. Congr. High-Speed Imaging and Photonics
    • Related Report
      2018 Research-status Report
    • Int'l Joint Research
  • [Presentation] Dual-energy X-ray computed tomography scanner using a room-temperature cadmium-telluride detector and a range-region counter.2018

    • Author(s)
      Watanabe, M., Sato, E., Oda, Y., Yoshida, S., Moriyama, H., Hagiwara, O., Matsukiyo, H., Enomoto, T., Kusachi, S.
    • Organizer
      SPIE Optics+Photonics
    • Related Report
      2018 Research-status Report
    • Int'l Joint Research
  • [Presentation] Triple-energy high-count-rate X-ray computed tomography scanner using a cooled cadmium-telluride detector.2018

    • Author(s)
      Moriyama, H., Sato, E., Oda, Y., Sato, Y., Yoshida, S., Yamaguchi, S., Hagiwara, O., Matsukiyo, H., Enomoto, T., Watanabe, M., Kusachi, S.
    • Organizer
      SPIE Optics+Photonics
    • Related Report
      2018 Research-status Report
    • Int'l Joint Research
  • [Presentation] Dual-energy high-count-rate X-ray computed tomography using a cerium-doped yttrium-aluminum-perovskite crystal and a photomultiplier tube.2018

    • Author(s)
      Sato, E., Oda, Y., Yoshida, S., Yamaguchi, S., Sato, Y., Moriyama, H., Hagiwara, O., Matsukiyo, H., Enomoto, T., Watanabe, M., Kusachi, S.
    • Organizer
      SPIE Optics+Photonics
    • Related Report
      2018 Research-status Report
    • Int'l Joint Research
  • [Presentation] 850-nm-peak high-sensitivity near-infrared-ray computed tomography scanner in the living-body window.2018

    • Author(s)
      Sato, Y., Takaoka, A., Sato, T., Sato, E., Oda, Y., Yoshida, S., Moriyama, H., Hagiwara, O., Matsukiyo, H., Enomoto, T., Watanabe, M., Kusachi, S.
    • Organizer
      17th Asia Oceania Congress of Medical Physics,
    • Related Report
      2017 Research-status Report
    • Int'l Joint Research
  • [Presentation] Triple-energy high-count-rate X-ray computed tomography scanner using a cadmium telluride detector.2018

    • Author(s)
      Sato, E., Sato, T., Oda, Y., Sato, Y., Yoshida, S., Yamaguchi, S., Hagiwara, O., Matsukiyo, H., Enomoto, T., Watanabe, M., Kusachi, S.
    • Organizer
      17th Asia Oceania Congress of Medical Physics,
    • Related Report
      2017 Research-status Report
    • Int'l Joint Research
  • [Presentation] Dual-energy high-count-rate X-ray computed tomography scanner using a cerium-doped yttrium aluminum perovskite crystal and a small-photomultiplier tube.2018

    • Author(s)
      Sato, T., Sato, E., Oda, Y., Sato, Y., Yoshida, S., Yamaguchi, S., Hagiwara, O., Matsukiyo, H., Enomoto, T., Watanabe, M., Kusachi, S.
    • Organizer
      17th Asia Oceania Congress of Medical Physics,
    • Related Report
      2017 Research-status Report
    • Int'l Joint Research
  • [Presentation] Measurement of x-ray spectra using a recent YAP(Ce)-MPPC detector.2017

    • Author(s)
      Sato, E., Oda, Y., Yoshida, S., Yamaguchi, S., Sato, Y., Ishii, T., Hagiwara, O., Matsukiyo, H., Enomoto, T., Watanabe, M., Kusachi, S.
    • Organizer
      SPIE Optics+Photonics.
    • Related Report
      2017 Research-status Report
    • Int'l Joint Research
  • [Presentation] Investigation of a high-sensitivity near-infrared-ray computed tomography scanner.2017

    • Author(s)
      Sato, E., Oda, Y., Yoshida, S., Yamaguchi, S., Sato, Y., Ishii, T., Hagiwara, O., Matsukiyo, H., Enomoto, T., Watanabe, M., Kusachi, S.
    • Organizer
      SPIE Optics+Photonics.
    • Related Report
      2017 Research-status Report
    • Int'l Joint Research
  • [Presentation] CdTe 検出器を使った高カウントレートクアッドエネルギーX線 CT スキャナー.2017

    • Author(s)
      佐藤英一,小田泰行,森山穂高,萩原令彦,松清大,榎本俊之,渡邉学,草地信也
    • Organizer
      高速度イメージングとフォトニクスに関する総合シンポジウム
    • Related Report
      2017 Research-status Report
  • [Presentation] マイクロ光電子増倍管を用いた高速Ⅹ線フォトンカウンティングとデュアル エネルギーCT への応用.2017

    • Author(s)
      佐藤英一,小田泰行,森山穂高,萩原令彦,松清大,榎本俊之,渡邉学,草地信也
    • Organizer
      高速度イメージングとフォトニクスに関する総合シンポジウム
    • Related Report
      2017 Research-status Report
  • [Presentation] 高空間分解能デュアル CdTe アレー検出器の特性とⅩ線イメージング.2017

    • Author(s)
      渡邉 学, 佐藤 英一,小田 泰行,萩原 令彦,松清 大,榎本 俊行, 森山 穂高,草地 信也
    • Organizer
      高速度イメージングとフォトニクスに関する総合シンポジウム
    • Related Report
      2017 Research-status Report
  • [Presentation] 小型光電子増倍管を用いた高速Ⅹ線フォトンカウンティングとデュアルエネルギー CT への応用.2017

    • Author(s)
      森山穂高, 佐藤英一,小田泰行,萩原令彦,松清大,榎本俊之,渡邉 学,草地信也
    • Organizer
      高速度イメージングとフォトニクスに関する総合シンポジウム
    • Related Report
      2017 Research-status Report

URL: 

Published: 2017-04-28   Modified: 2021-02-19  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI