• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Development of tissue equivalent material corresponding to wide x-ray energy range of dual energy CT

Research Project

Project/Area Number 17K10356
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeMulti-year Fund
Section一般
Research Field Radiation science
Research InstitutionKanazawa University

Principal Investigator

Ichikawa Katsuhiro  金沢大学, 保健学系, 教授 (40402630)

Project Period (FY) 2017-04-01 – 2020-03-31
Project Status Completed (Fiscal Year 2019)
Budget Amount *help
¥4,290,000 (Direct Cost: ¥3,300,000、Indirect Cost: ¥990,000)
Fiscal Year 2019: ¥1,040,000 (Direct Cost: ¥800,000、Indirect Cost: ¥240,000)
Fiscal Year 2018: ¥1,820,000 (Direct Cost: ¥1,400,000、Indirect Cost: ¥420,000)
Fiscal Year 2017: ¥1,430,000 (Direct Cost: ¥1,100,000、Indirect Cost: ¥330,000)
Keywordscomputed tomography / dual energy / phantom / CT number / soft tissue / X線コンピュータ断層撮影 / デュアルエネルギー / ファントム / エネルギー依存性 / 水等価物質 / 人体組織等価物質 / 希釈造影剤 / blood / X線 / コンピュータ断層撮影
Outline of Final Research Achievements

Phantom materials equivalent to the water and tissues in the human body, which can be used for energy-dependent analyses of the dual-energy computed tomography (DECT), did not exist. Therefore, we aimed to produce such materials that simulate energy dependencies of the water and the human tissues, using existing stable materials. Based on the linear attenuation coefficient data of various existing materials, we have successfully produced water- and soft tissue-equivalent materials having DECT number accuracies within 2HU. This outcome contributed to producing commercially available phantom materials; consequently, productions with equivalencies of water and several diluted iodines (i.e., enhanced blood vessels) have been achieved.

Academic Significance and Societal Importance of the Research Achievements

デュアルエネルギーX線コンピュータ断層撮影 (DECT)は,人体内組織のエネルギー分析が可能であるが,これまでのファントムを用いた数々の研究成果(論文)では,人体のエネルギー依存性と一致しない従来のファントムが用いられてきた.本研究成果により,正確に人体のエネルギー依存性をシミュレートする製品を,すべての研究者が入手できるようになった.このファントムによって,人体にDECTの様々なプロトコルを適用する前に検証実験が可能となることから,臨床における適切なDECT適用が進み,X線CTによる疾病診断の精度が向上する.

Report

(4 results)
  • 2019 Annual Research Report   Final Research Report ( PDF )
  • 2018 Research-status Report
  • 2017 Research-status Report

Research Products

(18 results)

All 2020 2019 2018 2017 Other

All Int'l Joint Research (1 results) Journal Article (10 results) (of which Int'l Joint Research: 4 results,  Peer Reviewed: 10 results,  Open Access: 1 results) Presentation (5 results) (of which Int'l Joint Research: 3 results) Remarks (2 results)

  • [Int'l Joint Research] AlgoMedica,Inc.(米国)

    • Related Report
      2019 Annual Research Report
  • [Journal Article] Determination of contrast medium dose for hepatic CT enhancement with improved body size dependency using a non-linear analysis based on pharmacokinetic principles2020

    • Author(s)
      Hibino T.、Ichikawa K.、Fang Y.、Ito S.、Kawashima H.、Bae K.T.
    • Journal Title

      Clinical Radiology

      Volume: 75

    • DOI

      10.1016/j.crad.2019.09.140

    • Related Report
      2019 Annual Research Report
    • Peer Reviewed / Int'l Joint Research
  • [Journal Article] A three-dimensional cross-directional bilateral filter for edge-preserving noise reduction of low-dose computed tomography images2019

    • Author(s)
      Ichikawa Katsuhiro、Kawashima Hiroki、Shimada Masato、Adachi Toshiki、Takata Tadanori
    • Journal Title

      Computers in Biology and Medicine

      Volume: 111 Pages: 103353-103353

    • DOI

      10.1016/j.compbiomed.2019.103353

    • Related Report
      2019 Annual Research Report
    • Peer Reviewed / Int'l Joint Research
  • [Journal Article] Quality evaluation of image‐based iterative reconstruction for CT: Comparison with hybrid iterative reconstruction2019

    • Author(s)
      Kawashima Hiroki、Ichikawa Katsuhiro、Matsubara Kosuke、Nagata Hiroji、Takata Tadanori、Kobayashi Satoshi
    • Journal Title

      Journal of Applied Clinical Medical Physics

      Volume: 20 Pages: 199-205

    • DOI

      10.1002/acm2.12597

    • Related Report
      2019 Annual Research Report
    • Peer Reviewed / Open Access / Int'l Joint Research
  • [Journal Article] Technical Note: Performance comparison of ultra‐high‐resolution scan modes of two clinical computed tomography systems2019

    • Author(s)
      Kawashima Hiroki、Ichikawa Katsuhiro、Takata Tadanori、Nagata Hiroji、Hoshika Minori、Akagi Noriaki
    • Journal Title

      Medical Physics

      Volume: 47 Pages: 488-497

    • DOI

      10.1002/mp.13949

    • Related Report
      2019 Annual Research Report
    • Peer Reviewed / Int'l Joint Research
  • [Journal Article] Automated determination of cardiac rest period on whole-heart coronary magnetic resonance angiography by extracting high-speed motion of coronary arteries2018

    • Author(s)
      Asou H, Imada N, Nishiyama Y, Sato T, Ichikawa K
    • Journal Title

      Clin Imaging

      Volume: 52 Pages: 183-188

    • DOI

      10.1016/j.clinimag.2018.07.006

    • Related Report
      2018 Research-status Report
    • Peer Reviewed
  • [Journal Article] Automated Classification of Calcification and Stent on Computed Tomography Coronary Angiography Using Deep Learning2018

    • Author(s)
      Hasegawa A, Lee Y, Takeuchi Y, Ichikawa K
    • Journal Title

      Japanese Journal of Radiological Technology

      Volume: 74 Issue: 10 Pages: 1138-1143

    • DOI

      10.6009/jjrt.2018_jsrt_74.10.1138

      10.6009/jjrt.2018_JSRT_74.10.1138

    • NAID

      130007499001

    • ISSN
      0369-4305, 1881-4883
    • Related Report
      2018 Research-status Report
    • Peer Reviewed
  • [Journal Article] Relationship between size-specific dose estimates and image quality in computed tomography depending on patient size2018

    • Author(s)
      Kawashima H, Ichikawa K, Hanaoka S, Matsubara K, Takata T
    • Journal Title

      J Appl Clin Med Phys

      Volume: 19 Pages: 246-251

    • DOI

      10.1002/acm2.12340

    • Related Report
      2018 Research-status Report
    • Peer Reviewed
  • [Journal Article] Effect of Tube Voltage on Contrast Enhancement and Contrast Medium Dose in Abdominal Contrast-enhanced Computed Tomography2018

    • Author(s)
      室賀 浩二, 福澤 明, 月岡 裕之, 穐澤 有香, 市川 勝弘
    • Journal Title

      Japanese Journal of Radiological Technology

      Volume: 74 Issue: 1 Pages: 61-67

    • DOI

      10.6009/jjrt.2018_jsrt_74.1.61

      10.6009/jjrt.2018_JSRT_74.1.61

    • NAID

      130006316002

    • ISSN
      0369-4305, 1881-4883
    • Related Report
      2018 Research-status Report 2017 Research-status Report
    • Peer Reviewed
  • [Journal Article] Comparative evaluation of image quality among different detector configurations using area detector computed tomography2018

    • Author(s)
      Miura Y, Ichikawa K, Fujimura I, Hara T, Hoshino T, Niwa S, Funahashi M
    • Journal Title

      Radiol Phys Technol.

      Volume: 11 Pages: 54-60

    • DOI

      10.1007/s12194-017-0437-y

    • Related Report
      2017 Research-status Report
    • Peer Reviewed
  • [Journal Article] Image Quality and Clinical Usefulness of Ray-summation Image Reconstructed from CT Data, Compared with Digital Radiography2017

    • Author(s)
      鈴木 省吾, 市川 勝弘, 玉木 繁
    • Journal Title

      Japanese Journal of Radiological Technology

      Volume: 73 Issue: 5 Pages: 372-381

    • DOI

      10.6009/jjrt.2017_jsrt_73.5.372

      10.6009/jjrt.2017_JSRT_73.5.372

    • NAID

      130007324171

    • ISSN
      0369-4305, 1881-4883
    • Related Report
      2017 Research-status Report
    • Peer Reviewed
  • [Presentation] Novel Ultra-high-resolution CT using a CMOS Detector Built on a Conventional Multislice CT Scanner's Detector2019

    • Author(s)
      Hiroki Kawashima, Katsuhiro Ichikawa, Satoshi Kobayashi,Tadanori Takata
    • Organizer
      RSNA 2019
    • Related Report
      2019 Annual Research Report
    • Int'l Joint Research
  • [Presentation] Dual energy CTにおける撮像方式の違いが画質に与える影響2019

    • Author(s)
      眞鍋 璃帆,市川 勝弘,川嶋広貴
    • Organizer
      第47回日本放射線技術学会秋季学術大会
    • Related Report
      2019 Annual Research Report
  • [Presentation] System Performance Comparison of Ultra-High-Resolution Scans Using Two Clinically Available Multi-Detector CT Systems2018

    • Author(s)
      Kawashima H, Ichikawa K, Kobayashi S, Akagi N, Nagata H
    • Organizer
      104th Scientific Assembly and Annual Meeting of RSNA
    • Related Report
      2018 Research-status Report
    • Int'l Joint Research
  • [Presentation] Arm Artifact Reduction Techniques for Computed Tomographic Images2017

    • Author(s)
      Hiroki Kawashima, Katsuhiro Ichikawa,Tadanori Takata
    • Organizer
      Radiological Society of North America’s 103th Scientific Assembly and Annual Meeting
    • Related Report
      2017 Research-status Report
    • Int'l Joint Research
  • [Presentation] Pre-filtered 3-dimensional bilateral filtering for noise reduction of computer tomography images2017

    • Author(s)
      Katsuhiuro Ichikawa, Hiroki Kawashima, Tadanori Takata, Kosuke Matsubara, Hiroji Nagata
    • Organizer
      JSCT 5th Annual Meeting
    • Related Report
      2017 Research-status Report
  • [Remarks] 金沢大学 市川研究室

    • URL

      http://ichiken.w3.kanazawa-u.ac.jp/

    • Related Report
      2019 Annual Research Report 2018 Research-status Report
  • [Remarks] 金沢大学 市川研究室,研究内容

    • URL

      http://ichiken.w3.kanazawa-u.ac.jp/studies.html

    • Related Report
      2017 Research-status Report

URL: 

Published: 2017-04-28   Modified: 2021-02-19  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi