Study on non-uniformity correction of the Gafchromic film and three-dimensional measurement of CT
Project/Area Number |
17K10380
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Multi-year Fund |
Section | 一般 |
Research Field |
Radiation science
|
Research Institution | Osaka Butsuryo University |
Principal Investigator |
|
Co-Investigator(Kenkyū-buntansha) |
野口 敦司 大阪物療大学, 保健医療学部, 教授 (10716202)
丹喜 信義 大阪物療大学, 保健医療学部, 助教 (60441573)
|
Project Period (FY) |
2017-04-01 – 2020-03-31
|
Project Status |
Completed (Fiscal Year 2019)
|
Budget Amount *help |
¥4,680,000 (Direct Cost: ¥3,600,000、Indirect Cost: ¥1,080,000)
Fiscal Year 2019: ¥650,000 (Direct Cost: ¥500,000、Indirect Cost: ¥150,000)
Fiscal Year 2018: ¥2,210,000 (Direct Cost: ¥1,700,000、Indirect Cost: ¥510,000)
Fiscal Year 2017: ¥1,820,000 (Direct Cost: ¥1,400,000、Indirect Cost: ¥420,000)
|
Keywords | エックス線 / CT / 線量計測 / ラジオクロミックフィルム / 三次元計測 / Radiochromic films / Computed Tomography / ガフクロミックフィルム / 線量分布 / 三次元線量計測 / 半円柱ファントム / 三次元線量分布 / Radiochromic film / 不均一性 / 紫外線ーA / ガフクロミック フィルム / 均一性 |
Outline of Final Research Achievements |
The correction method of an uncertainty at low-dose range and non-uniformity error have been developed for three-dimensional X-ray CT dosimetry using a film-type dosimeter. The density equivalent to the beginning of the linear portion of the density-dose curve was used as the base density, and the uncertainty line portion of 2 to 10 mGy was corrected. In addition, double exposure method using ultraviolet rays for correcting non-uniformity error. In this film type dosimeter, the density increases in the white LED. Based on the principle of white LEDs, it was divided into yellow and blue, and it was clarified that the influence of blue light with a wavelength of 410 nm, which is almost the wavelength of ultraviolet light, is strong. In addition, for the creation of the three-dimensional dose distribution map, the two-dimensional plane dose distribution was rotated to create an image of the cross section of the virtual three-dimensional dose distribution.
|
Academic Significance and Societal Importance of the Research Achievements |
X線CTの線量分布の把握は困難である.3次元的かつ連続的に変化するX線量を高分解で把握することは新たな計測方法の開発として学術的な意義がある.特に最近多くの施設で行われている一度に広い範囲を検査できる検査方法についての線量計測法は現状の方法では大変困難が伴う.しかし,本方法では検査領域の広さにとらわれず,どのような場合においても線量計測が簡便にできるという学術的な意義がある. また,現状では実際のX線量が把握でき,撮影方法の工夫や新たな方法の開発によって線量を低減させることも可能となることで社会的意義がある.
|
Report
(4 results)
Research Products
(29 results)
-
[Journal Article] Temporal Characterization of the Flat-Bed Scanner Influencing Dosimetry Using Radiochromic Film2019
Author(s)
Rumi Gotanda, Toshizo Katsuda, Tatsuhiro Gotanda, Nobuyoshi Tanki, Hidetoshi Yatake, Yasuyuki Kawaji, Tadao Kuwano, Takuya Akagawa, Akihiko Tabuchi, Atsushi Ono, Shinichi Arao
-
Journal Title
IFMBE Proceedings
Volume: 68
Pages: 537-539
DOI
ISBN
9789811090226, 9789811090233
Related Report
Peer Reviewed
-
[Journal Article] Evaluation of effective energy distribution of 320-multidetector CT using GAFCHROMIC EBT32018
Author(s)
Tatsuhiro Gotanda, Toshizo Katsuda, Rumi Gotanda, Takuya Akagawa, Tadao Kuwano, Nobuyoshi Tanki, Hidetoshi Yatake, Yasuyuki Kawaji, Takashi Amano, Shinichi Arao, Atsushi Ono, Akihiko Tabuchi
-
Journal Title
International Fedration Medical and Biological Engineering Proceedings
Volume: 68(3)
Pages: 525-528
DOI
ISBN
9789811090226, 9789811090233
Related Report
Peer Reviewed
-
-
-
[Journal Article] Size and Shape of Spherical Objects on Full-Field Digital Mammography and Digital Breast Tomosynthesis Images.2018
Author(s)
Hidetoshi Yatake, Yuka Sawai, Takahiro Kozuka, Yoshihiro Takeda, Mariko Kajihara, Toshizo Katsuda, Rumi Gotanda, Tatsuhiro Gotanda, Shuji Abe, Makoto Shimada, Nobuyoshi Tanki, Toshio Nishi, Hideo Inaji
-
Journal Title
IFMBE Proc.
Volume: 68
Pages: 45-48
Related Report
Peer Reviewed
-
-
-
[Journal Article] Temporal characterization of the flat-bed scanner influencing dosimetry using radiochromic film.2018
Author(s)
Rumi Gotanda, Toshizo Katsuda, Tatsuhiro Gotanda, Nobuyoshi Tanki, Hidetoshi Yatake, Yasuyuki Kawaji, Tadao Kuwano, Takuya Akagawa, Akihiko Tabuchi, Atsushi Ono, Shinichi Arao
-
Journal Title
IFMBE Proc.
Volume: 68
Pages: 537-539
Related Report
Peer Reviewed
-
[Journal Article] Evaluation of effective energy distribution of 320-multidetector CT using GAFCHROMIC EBT3.2018
Author(s)
Tatsuhiro Gotanda, Toshizo Katsuda, Rumi Gotanda, Takuya Akagawa, Tadao Kuwano, Nobuyoshi Tanki, Hidetoshi Yatake, Yasuyuki Kawaji, Takashi Amano, Shinichi Arao, Atsushi Ono, Akihiko Tabuchi
-
Journal Title
IFMBE Proc.
Volume: 68
Pages: 525-528
Related Report
Peer Reviewed
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
[Presentation] Evaluation of novel film-folding type phantom for X-ray CT dosimetry2017
Author(s)
Nobuyoshi Tanki, Toshizo Katsuda, Tadao Kuwano, Rumi Gotanda, Tatsuhiro Gotanda, Tomoya Oue, Yuuna Sugihara, Shinya Imai, Takuya Akagawa, Yasuyuki Kawaji,
Organizer
8th JKMP2017
Related Report
Int'l Joint Research