• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Development of the osteoinductive devices using magnetostatic stimulus

Research Project

Project/Area Number 18390511
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section一般
Research Field 補綴理工系歯学
Research InstitutionTohoku University

Principal Investigator

TAKADA Yukyo  Tohoku University, 大学院・歯学研究科, 准教授 (10206766)

Co-Investigator(Kenkyū-buntansha) KIKUCHI Masafumi  東北大学, 大学院・歯学研究科, 助教 (50250791)
TAKAHASHI Masatoshi  東北大学, 大学院歯学研究科, 助教 (50400255)
奥野 攻  東北大学, 大学院・歯学研究科, 教授 (50014080)
Co-Investigator(Renkei-kenkyūsha) OKUNO Osamu  東北大学, 大学院・歯学研究科, 教授 (50014080)
Project Period (FY) 2006 – 2008
Project Status Completed (Fiscal Year 2008)
Budget Amount *help
¥18,090,000 (Direct Cost: ¥15,300,000、Indirect Cost: ¥2,790,000)
Fiscal Year 2008: ¥2,730,000 (Direct Cost: ¥2,100,000、Indirect Cost: ¥630,000)
Fiscal Year 2007: ¥9,360,000 (Direct Cost: ¥7,200,000、Indirect Cost: ¥2,160,000)
Fiscal Year 2006: ¥6,000,000 (Direct Cost: ¥6,000,000)
Keywords静磁場 / 磁石構造体 / 骨組織 / 動物実験 / 骨誘導 / 歯科用磁性アタッチメント / 仮骨 / 骨様組織 / 軟骨性内骨化 / ウサギ / in vivo
Research Abstract

本研究課題では、骨誘導デバイスの開発を前提に、永久磁石を用いた歯科用磁性アタッチメントの静磁場をウサギの骨形成過程で付与し、静磁場の骨形成に及ぼす影響を調べた。その結果、磁性アタッチメントによる静磁場は、骨形成の初期において、骨形成速度の向上に寄与し、その現象は骨の成長を促す骨牙細胞の増殖と分化の加速に起因することが明らかになった。これより、永久磁石を利用した骨誘導デバイスの可能性が示唆された。

Report

(4 results)
  • 2008 Annual Research Report   Final Research Report ( PDF )
  • 2007 Annual Research Report
  • 2006 Annual Research Report
  • Research Products

    (12 results)

All 2009 2008 2007

All Journal Article (7 results) (of which Peer Reviewed: 6 results) Presentation (5 results)

  • [Journal Article] Galvanic corrosion of ferritic stainless steels used for dental magnetic attachments in contact with an iron-platinum magnet2008

    • Author(s)
      Keisuke Nakamura, Yukyo Takada, Masanobu Yoda, Kohei Kimura, Osamu Okuno
    • Journal Title

      Dent MaterJ 27

      Pages: 203-210

    • NAID

      110006649449

    • Related Report
      2008 Final Research Report
    • Peer Reviewed
  • [Journal Article] Galvanic corrosion between dental precious alloys and magnetic stainless steels used for dental magnetic attachments2008

    • Author(s)
      Noriko Takahashi, Yukyo Takada, Osamu Okuno
    • Journal Title

      Dent Mater J 27

      Pages: 237-242

    • NAID

      110006649454

    • Related Report
      2008 Annual Research Report 2008 Final Research Report
    • Peer Reviewed
  • [Journal Article] Corrosion characteristics of magnetic assemblies composing dental magnetic attachments2008

    • Author(s)
      Yukyo Takada, Noriko Takahashi, Osamu Okuno
    • Journal Title

      Interface Oral Health Science 2007

      Pages: 343-344

    • Related Report
      2008 Annual Research Report 2008 Final Research Report
    • Peer Reviewed
  • [Journal Article] Galvanic corrosion of ferritic stainless steels used for dental magnetic attachments in contact with an iron-platinum magnet2008

    • Author(s)
      Keisuke Nakamura, Yukyo Takada, Masanobu Yoda, Kohei Kimura, Osamu Okuno
    • Journal Title

      Dent Mater J 27

      Pages: 203-210

    • NAID

      110006649449

    • Related Report
      2008 Annual Research Report
    • Peer Reviewed
  • [Journal Article] 白金鉄磁石合金の骨形成への影響2007

    • Author(s)
      向山泰泉, 高田雄京, 奥野 攻, 越後成志
    • Journal Title

      歯科材料・器械 26

      Pages: 256-265

    • NAID

      110006279266

    • Related Report
      2008 Final Research Report
    • Peer Reviewed
  • [Journal Article] Electrochemical behavior and released ions of the stainless steels used for dental magnetic attachments2007

    • Author(s)
      Yukyo Takada, Noriko Takahashi, Osamu Okuno
    • Journal Title

      J J Mag Dent 16

      Pages: 49-52

    • Related Report
      2008 Final Research Report 2007 Annual Research Report
  • [Journal Article] 白金鉄磁石合金の骨形成への影響2007

    • Author(s)
      向山泰泉, 高田雄京, 奥野攻, 越後成志
    • Journal Title

      歯科材料・器械 26

      Pages: 256-265

    • NAID

      110006279266

    • Related Report
      2007 Annual Research Report
    • Peer Reviewed
  • [Presentation] 永久磁石を用いた静磁場刺激による骨誘導2009

    • Author(s)
      高田雄京
    • Organizer
      日本機械学会第21回バイオエンジニアリング講演会
    • Place of Presentation
      北海道
    • Year and Date
      2009-01-24
    • Related Report
      2008 Annual Research Report 2008 Final Research Report
  • [Presentation] Corrosion resistance of precious casting alloys and magnetic stainless steels used for dental magnetic attachments2007

    • Author(s)
      N. Takahashi, Y. Takada, O. Okuno
    • Organizer
      49th General Session of the Japanese Society for Dental Materials and Devices
    • Place of Presentation
      Hokkaido
    • Year and Date
      2007-05-12
    • Related Report
      2008 Final Research Report 2007 Annual Research Report
  • [Presentation] Bone compatibility of dental magnetic attachments with static magnetic field2007

    • Author(s)
      Yukyo TAKADA and Osamu OKUNO
    • Organizer
      IADR
    • Place of Presentation
      New Orleans USA
    • Related Report
      2008 Final Research Report
  • [Presentation] Electrochemical behavior and released ions of the stainless steels used for dental magnetic attachments2007

    • Author(s)
      Y. Takada, N. Takahashi and O. Okuno
    • Organizer
      6th International Conference on MagneticApplications in Dentistry(JSMAD)
    • Place of Presentation
      Web
    • Related Report
      2008 Final Research Report
  • [Presentation] Corrosion Characteristics of Magnetic Assemblies Composing Dental Magnetic Attachments2007

    • Author(s)
      Yukyo TAKADA Noriko TAKAHASHI and Osamu OKUNO
    • Organizer
      2nd International Symposium for Interface Oral Health Science in SENDAI
    • Place of Presentation
      Sendai
    • Related Report
      2008 Final Research Report

URL: 

Published: 2006-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi