• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

The development of MDP coil for coil embolization of cerebral aneurysm

Research Project

Project/Area Number 18K08933
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeMulti-year Fund
Section一般
Review Section Basic Section 56010:Neurosurgery-related
Research InstitutionAkita Cerebrospinal and Cardiovascular Center

Principal Investigator

KOKUBUN Kohei  秋田県立循環器・脳脊髄センター(研究所), 脳神経外科学研究部, 客員研究員 (90775727)

Co-Investigator(Kenkyū-buntansha) 清水 宏明  秋田大学, 医学系研究科, 教授 (20506638)
高橋 和孝  秋田大学, 医学部附属病院, 講師 (60321999)
Project Period (FY) 2018-04-01 – 2023-03-31
Project Status Completed (Fiscal Year 2022)
Budget Amount *help
¥4,290,000 (Direct Cost: ¥3,300,000、Indirect Cost: ¥990,000)
Fiscal Year 2022: ¥1,040,000 (Direct Cost: ¥800,000、Indirect Cost: ¥240,000)
Fiscal Year 2021: ¥1,170,000 (Direct Cost: ¥900,000、Indirect Cost: ¥270,000)
Fiscal Year 2020: ¥520,000 (Direct Cost: ¥400,000、Indirect Cost: ¥120,000)
Fiscal Year 2019: ¥520,000 (Direct Cost: ¥400,000、Indirect Cost: ¥120,000)
Fiscal Year 2018: ¥1,040,000 (Direct Cost: ¥800,000、Indirect Cost: ¥240,000)
Keywordsmulti-detach point coil / 脳動脈瘤塞栓術 / 塞栓用coil / 電気離脱式coil / 機械離脱式coil / 脳動脈瘤 / MDP coil
Outline of Final Research Achievements

The purpose of this study is the development of MDP(multi detach point)coil for coil embolization of cerebral aneurysm.We made MDP prototype coil.MDP coil has 2 detach point.We used the electrically Detachable Coil and the mechanical detachable coil. The electrically Detachable Coil has detach point made by PVA(polyvinyl alcohol) .MDP prototype coil was made by these coils that were connected.
We performed experiment of detach system of MDP prototype coil by using Vascular model.There were no troubles in 2 detach point of MDP prototype coil.

Academic Significance and Societal Importance of the Research Achievements

瘤内塞栓術ではレアメタルであるplatinumを素材とした塞栓術用のcoilが使用されるが、現在流通しているcoilには必要な長さを自在に瘤内に離脱できるsystemがない。瘤内塞栓術中に使用し一度回収したcoilは、場合によってはその手術中に再利用されず医療資源の損失となりうる。またcoilの回収は手術時間の延長にも関与する。今回発案したmulti-detach point coil(MDP coil)には、医療経済に貢献しかつ瘤内塞栓術の成績向上に寄与する可能性があると考えられる。

Report

(6 results)
  • 2022 Annual Research Report   Final Research Report ( PDF )
  • 2021 Research-status Report
  • 2020 Research-status Report
  • 2019 Research-status Report
  • 2018 Research-status Report

URL: 

Published: 2018-04-23   Modified: 2024-01-30  