Influence of interactive behavior between load bearing and insulation members on the structural stability of steel buildings subjected to fire
Project/Area Number |
20246088
|
Research Category |
Grant-in-Aid for Scientific Research (A)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
Building structures/materials
|
Research Institution | University of Tsukuba |
Principal Investigator |
SUZUKI Hiroyuki University of Tsukuba, 大学院・システム情報工学研究科, 教授 (20114093)
|
Co-Investigator(Kenkyū-buntansha) |
TSUJIMOTO Makoto 東京理科大学, 工学部, 教授 (90115600)
HARADA Kazunori 京都大学, 大学院・工学研究科, 教授 (90198911)
KINUGASA Hideyuki 東京理科大学, 理工学部, 教授 (00224999)
OOMIYA Yushihumi 東京理科大学, 理工学部, 教授 (10287469)
HIRASHIMA Takeo 千葉大学, 大学院・工学研究科, 准教授 (20334170)
SUZUKI Junichi 建築研究所, 防火研究グループ, 研究員 (10453846)
|
Project Period (FY) |
2008 – 2010
|
Project Status |
Completed (Fiscal Year 2010)
|
Budget Amount *help |
¥48,100,000 (Direct Cost: ¥37,000,000、Indirect Cost: ¥11,100,000)
Fiscal Year 2010: ¥5,070,000 (Direct Cost: ¥3,900,000、Indirect Cost: ¥1,170,000)
Fiscal Year 2009: ¥15,210,000 (Direct Cost: ¥11,700,000、Indirect Cost: ¥3,510,000)
Fiscal Year 2008: ¥27,820,000 (Direct Cost: ¥21,400,000、Indirect Cost: ¥6,420,000)
|
Keywords | 鋼構造耐火 / 石膏ボード乾式壁 / 耐火被覆鋼柱 / 壁・被覆材の火災時変形追随性能 / 架構の火災時リダンダンシー / 架構の火災時変形 / 地震被災架構の残余耐火性能 / 建築構造・材料 / 防災 / 火災 / 耐震 / 地震後火災 / 高温構造安定 / 変形追随性 |
Research Abstract |
Although present fire resistance design rules out the displacement of buildings, this is not true in practice. In fact, local displacements of heated members and the vicinities are generally not small. In view of this, a study is made on the interactive behaviors of load bearing and thermal insulating members of steel structures subjected to fire. The maximum displacements which heated steel frames can bear stably in fire have been clarified analytically. Two series of full scale tests have been also conducted to see whether insulation members can follow the above displacements. One is the heating test of displaced gypsum board walls. Another is simultaneous loading and heating test of protected steel box columns, where sprayed rock wool, rock wool felt sheet and calcium silicate plates were chosen for protection materials.
|
Report
(4 results)
Research Products
(51 results)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
[Presentation] 損傷を被った間仕切壁の耐火性能に関する実験その1:研究概要, その2:面内せん断実験, その3:加熱実験, その4:考察2009
Author(s)
鈴木弘之, 大宮喜文, 鈴木淳一, 小寺賢, 市原嵩紘, 伊藤卓, 大熊晃一路, 足立格
Organizer
日本建築学会2009年度大会
Place of Presentation
仙台
Year and Date
2009-08-29
Related Report
-
-
-
-
-
-
-
-
-
-