Budget Amount *help |
¥18,200,000 (Direct Cost: ¥14,000,000、Indirect Cost: ¥4,200,000)
Fiscal Year 2010: ¥1,950,000 (Direct Cost: ¥1,500,000、Indirect Cost: ¥450,000)
Fiscal Year 2009: ¥5,590,000 (Direct Cost: ¥4,300,000、Indirect Cost: ¥1,290,000)
Fiscal Year 2008: ¥10,660,000 (Direct Cost: ¥8,200,000、Indirect Cost: ¥2,460,000)
|
Research Abstract |
We improved the practical design of seismically-isolated structures with the state of the art analysis capabilities to capture extreme isolator behavior. First, a new analytical model was developed for the elastomeric isolation bearings under severe large shear deformation and axial load. Next, the safety of seismically-isolated buildings was carefully evaluated using the improved analytical model for long-period ground motions that might be produced by large earthquakes in the near future.
|