• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Improvement of legion detectability and development of further radiation reduction at 64-detector CT

Research Project

Project/Area Number 20591449
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionKumamoto University

Principal Investigator

FUNAMA Yoshinori  Kumamoto University, 大学院・生命科学研究部, 助教 (30380992)

Co-Investigator(Kenkyū-buntansha) AWAI Kazuo  広島大学, 大学院・医歯薬学総合研究科, 教授 (30294573)
Project Period (FY) 2008 – 2010
Project Status Completed (Fiscal Year 2010)
Budget Amount *help
¥4,680,000 (Direct Cost: ¥3,600,000、Indirect Cost: ¥1,080,000)
Fiscal Year 2010: ¥1,170,000 (Direct Cost: ¥900,000、Indirect Cost: ¥270,000)
Fiscal Year 2009: ¥1,170,000 (Direct Cost: ¥900,000、Indirect Cost: ¥270,000)
Fiscal Year 2008: ¥2,340,000 (Direct Cost: ¥1,800,000、Indirect Cost: ¥540,000)
KeywordsCT / 検出能 / 被曝線量 / 画質 / CNR / ATCM / Image noise / Radiation dose / Detectability / Helical scan / Axial scan / AEC technique / Dual energy subtraction
Research Abstract

The purpose of our study was to deal with improvement of legion detectability and further reduction of radiation dose at 64-detector CT. First, we have studied about comparison of step-and-shoot- and helical- scan. Helical scan realized the improvement of legion detectability and enabled the stable CT examination. Second, we have studied the development of contrast-to-noise ratio (CNR) based modulation technology to further reduce the radiation dose. Novel CNR technology enabled the both dose reduction and improved image quality in CT scanning.

Report

(4 results)
  • 2010 Annual Research Report   Final Research Report ( PDF )
  • 2009 Annual Research Report
  • 2008 Annual Research Report
  • Research Products

    (9 results)

All 2010 2009 2008

All Journal Article (4 results) (of which Peer Reviewed: 4 results) Presentation (5 results)

  • [Journal Article] Cone-beam technique for 64-MDCT of lung : image quality comparison with stepwise (step-and-shoot) technique2009

    • Author(s)
      Funama Y, Awai K, Taguchi K, et al.
    • Journal Title

      American Journal of Roentgenology 192(1)

      Pages: 273-278

    • Related Report
      2010 Final Research Report
    • Peer Reviewed
  • [Journal Article] Image noise and radiation dose using an automatic tube current modulation technique at 64-detector computed tomography : effect of off-center patient position, bowtie filter type, and scan projection radiograph2009

    • Author(s)
      Funama Y, Awai K, Liu D, et al.
    • Journal Title

      J Comput Assist Tomogr 33

      Pages: 973-977

    • Related Report
      2010 Final Research Report
    • Peer Reviewed
  • [Journal Article] Image noise and radiation dose using an automatic tube current modulation technique at 64-detector computed tomography : effect of off-center patient position, bowtie filter type, and scan projection radiograph2009

    • Author(s)
      Funama Y
    • Journal Title

      J Comput Assist Tomogr. 33

      Pages: 973-977

    • Related Report
      2009 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Cone-beam technique for 64-MDCT of lung : image quality comparison with stepwise (step-and-shoot)technique2009

    • Author(s)
      Funama Y
    • Journal Title

      American Journal of Roentgenology 192(1)

      Pages: 273-278

    • Related Report
      2008 Annual Research Report
    • Peer Reviewed
  • [Presentation] CNR-based CT Automatic Exposure Control System : Physics Principles, Scanning Technique, and Clinical Implementation2010

    • Author(s)
      Sugaya Y, Funama Y Awai K, et al.
    • Organizer
      Radiological Society of North America (RSNA)
    • Place of Presentation
      McCormick Place, Chicago, USA
    • Year and Date
      2010-11-28
    • Related Report
      2010 Final Research Report
  • [Presentation] CNR-based CT Automatic Exposure Control System : Physics Principles, Scanning Technique, and Clinical Implementation2010

    • Author(s)
      Sugaya Y
    • Organizer
      Radiological Society of North America (RSNA)
    • Place of Presentation
      McCormic Place, Chicago, USA
    • Year and Date
      2010-11-28
    • Related Report
      2010 Annual Research Report
  • [Presentation] A novel dose modulation technique at abdominal multidetector CT based on contrast-to-noise ratio : theoretical background and initial clinical experience2009

    • Author(s)
      Funama Y, Awai K, Irie T, et al.
    • Organizer
      Radiological Society of North America
    • Place of Presentation
      McCormick Place, Chicago, USA, RSNA
    • Year and Date
      2009-12-02
    • Related Report
      2010 Final Research Report
  • [Presentation] A novel dose modulation technique at abdominal multidetector CT based on contrast-to-noise ratio : theoretical background and initial clinical experience2009

    • Author(s)
      Funama Y
    • Organizer
      Radiological Society of North America(RSNA)
    • Place of Presentation
      McCormic Place, Chicago, USA
    • Year and Date
      2009-12-02
    • Related Report
      2009 Annual Research Report
  • [Presentation] 肺野のHelical HRCTスキャンとAxial HRCTスキャンの比較2008

    • Author(s)
      筧清孝、羽手村昌宏、橋田昌弘、船間芳憲
    • Organizer
      日本放射線技術学会総会
    • Place of Presentation
      パシフィコ横浜
    • Year and Date
      2008-04-04
    • Related Report
      2010 Final Research Report

URL: 

Published: 2008-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi