| Project/Area Number |
20K16738
|
| Research Category |
Grant-in-Aid for Early-Career Scientists
|
| Allocation Type | Multi-year Fund |
| Review Section |
Basic Section 52040:Radiological sciences-related
|
| Research Institution | St. Luke's International University |
Principal Investigator |
Horiuchi Saya 聖路加国際大学, 聖路加国際病院, 医員 (90867029)
|
| Project Period (FY) |
2020-04-01 – 2025-03-31
|
| Project Status |
Completed (Fiscal Year 2024)
|
| Budget Amount *help |
¥4,160,000 (Direct Cost: ¥3,200,000、Indirect Cost: ¥960,000)
Fiscal Year 2022: ¥1,040,000 (Direct Cost: ¥800,000、Indirect Cost: ¥240,000)
Fiscal Year 2021: ¥1,560,000 (Direct Cost: ¥1,200,000、Indirect Cost: ¥360,000)
Fiscal Year 2020: ¥1,560,000 (Direct Cost: ¥1,200,000、Indirect Cost: ¥360,000)
|
| Keywords | MRI / 手関節MRI / TFCC / 三角線維軟骨複合体 / 放射線科学関連 |
| Outline of Research at the Start |
TFCCの靭帯構造、軟骨、骨形態の包括的なMRI診断の実現と臨床普及を目指し次の3つの研究を行う。 [1] TFCC靭帯構造の尺骨の損傷・変性のMRI診断能検討を行う。またボランティア群においてTFCC構造の動態解析を行う。 [2] T2マッピングを用て手関節軟骨のT2値を定量し、健常軟骨T2値の同定と変性・損傷による変化が軟骨の組成へおよぼす影響を検討する。 [3] ZTEによる尺骨形態解析ZTEにより尺骨形態についてCTと比較した場合の描出能・診断精度を検討し、骨病変診断や術前検査を目的としたCTの削減と、それによる放射線被曝量の低減、時間・費用・苦痛などのデメリットの低減効果を検討する。
|
| Outline of Final Research Achievements |
This project created a non-invasive 3-D MRI protocol to cut CT use when evaluating the TFCC and wrist bones. We optimised sequences, measured anatomy, and validated clinically. The final protocol merges T2 mapping, ZTE and high-res T1-weighted 3-D GRE, simultaneously depicting cortical bone and soft tissue. In 30 healthy volunteers MRI and CT were acquired in identical positions and co-registered. Cortical thickness at the ulnar styloid foveal attachment was 0.4 mm greater than elsewhere, confirming classic anatomy. MRI and CT values matched closely (r = 0.93), allowing CT to be skipped and saving 2 mGy, 65 mGy cm, 45 % cost and 10 min per scan. Patient enrolment is ongoing (18/50) with similar image quality. After completion we will detail dose, cost and workflow gains and deploy an MRI-first pathway. Presented at RSNA 2024 (Cum Laude), these results promise low-dose, high-precision wrist imaging to support better orthopaedic and radiologic care.
|
| Academic Significance and Societal Importance of the Research Achievements |
本プロトコルを用いれば、1検査あたりCTDIvol約2 mGy・DLP約65 mGy cmの被ばくを回避し、検査費用を約45%、撮像時間を10分短縮できる見込みが得られた。放射線を使わず骨と靱帯を立体的に評価できる点は画像診断学に新しい流れをもたらし、手関節障害の早期発見や病態解明、治療計画の精度向上に寄与する。被ばく低減と医療コスト削減という社会的要請を満たしながら、患者の苦痛と通院負担を軽減できることから、整形外科・放射線科の臨床現場に利点をもたらすと期待している。
|