REASSESSMENT OF DUCTILITY INDEX AND RESIDUAL AXIAL LOAD CAPACITY FOR "SHORT SHEAR COLUMN" AND "SHEAR COLUMN" OF R/C BUILDINGS
Project/Area Number |
21360269
|
Research Category |
Grant-in-Aid for Scientific Research (B)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
Building structures/materials
|
Research Institution | Tokyo Metropolitan University |
Principal Investigator |
YOSHIMURA Manabu 首都大学東京, 都市環境科学研究科, 教授 (20210768)
|
Co-Investigator(Kenkyū-buntansha) |
NAKAMURA Takaya 新潟大学, 大学院・自然科学系, 准教授 (50305421)
|
Project Period (FY) |
2009 – 2011
|
Project Status |
Completed (Fiscal Year 2011)
|
Budget Amount *help |
¥17,810,000 (Direct Cost: ¥13,700,000、Indirect Cost: ¥4,110,000)
Fiscal Year 2011: ¥1,950,000 (Direct Cost: ¥1,500,000、Indirect Cost: ¥450,000)
Fiscal Year 2010: ¥8,060,000 (Direct Cost: ¥6,200,000、Indirect Cost: ¥1,860,000)
Fiscal Year 2009: ¥7,800,000 (Direct Cost: ¥6,000,000、Indirect Cost: ¥1,800,000)
|
Keywords | 鉄筋コンクリート柱 / せん断破壊 / 崩壊 / 靭性指標 / 残存軸耐力 / 軸力減少 / 鉄筋コンクリート建物 / 旧基準 / 載荷履歴 / 短柱 |
Research Abstract |
Ductility Index and Residual Axial Load Capacities of shear columns were studied. The major findings from the study are as follows. 1. The analytical method to determine Ductility Index was proposed, which would lead to its more reasonable evaluation. 2. The analytical method to determine Residual Axial Load Capacities was proposed, and its validity was examined. 3. It was experimentally revealed that columns for which axial load was decreased below the initial level showed larger collapse drift than columns for which axial load was kept constant.
|