• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Cerebral perfusion and metabolism study of brain ischemia using an integrated PET/ MR system.

Research Project

Project/Area Number 21591561
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionOsaka University

Principal Investigator

SHIMOSEGAWA Eku  大阪大学, 大学院・医学系研究科, 准教授 (30370258)

Co-Investigator(Kenkyū-buntansha) HATAZAWA Jun  大阪大学, 大学院・医学系研究科, 教授 (70198745)
Project Period (FY) 2009 – 2011
Project Status Completed (Fiscal Year 2011)
Budget Amount *help
¥4,290,000 (Direct Cost: ¥3,300,000、Indirect Cost: ¥990,000)
Fiscal Year 2011: ¥650,000 (Direct Cost: ¥500,000、Indirect Cost: ¥150,000)
Fiscal Year 2010: ¥650,000 (Direct Cost: ¥500,000、Indirect Cost: ¥150,000)
Fiscal Year 2009: ¥2,990,000 (Direct Cost: ¥2,300,000、Indirect Cost: ¥690,000)
Keywords脳・神経 / 神経科学 / 放射線 / 脳神経 / PET / MRI
Research Abstract

We investigated quantitative cerebral perfusion and oxygen metabolism measurement and neuro-inflammation imaging in the rat model of brain ischemia using an original integrated PET/ MR system. By the simultaneous scanning of PET and MR images, PET findings were accurately comparable with the infarcted areas on MR T_2-weighted images.

Report

(4 results)
  • 2011 Annual Research Report   Final Research Report ( PDF )
  • 2010 Annual Research Report
  • 2009 Annual Research Report
  • Research Products

    (33 results)

All 2012 2011 2010 2009 Other

All Journal Article (14 results) (of which Peer Reviewed: 14 results) Presentation (16 results) Remarks (3 results)

  • [Journal Article] Simultaneous PET/ MR body imaging in rats : initial experiences with an integrated PET/ MRI scanner2012

    • Author(s)
      Tatsumi M, Yamamoto S, Imaizumi M, Watabe T, Kanai Y, Aoki M, Kato H, Shimosegawa E, Hatazawa J.
    • Journal Title

      Ann Nucl Med

    • NAID

      10030788685

    • Related Report
      2011 Final Research Report
    • Peer Reviewed
  • [Journal Article] Simultaneous imaging using Si-PM-based PET and MRI for development of an integrated PET/ MRI system2012

    • Author(s)
      Yamamoto S, Watabe T, Watabe H, Aoki M, Sugiyama E, Imaizumi M, Kanai Y, Shimosegawa E, Hatazawa J.
    • Journal Title

      Phys Med Biol

      Volume: 57(2)

    • Related Report
      2011 Final Research Report
    • Peer Reviewed
  • [Journal Article] Simultaneous imaging using Si-PM-based PET and MRI for development of an integrated PET/MEI system2012

    • Author(s)
      Yamamoto S, Watabe T, Watabe H, Aoki M, Sugiyama E, Imaizumi M, Kanai Y, Shimosegawa E, Hatazawa J
    • Journal Title

      Phys Med Biol

      Volume: 57-2 Issue: 2 Pages: N1-N13

    • DOI

      10.1088/0031-9155/57/2/n1

    • Related Report
      2011 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Simultaneous PET/MR body imaging in rats : initial experiences with an integrated PET/MRI scanner2012

    • Author(s)
      Tatsumi M, Yamamoto S, Imaizumi M, et al
    • Journal Title

      Ann Nucl Med.

      Volume: Feb 23(in press) Issue: 5 Pages: 444-449

    • DOI

      10.1007/s12149-012-0581-8

    • Related Report
      2011 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Interference between PET and MRI sub-systems in a silicon-photomultiplier-based PET/ MRI system2011

    • Author(s)
      Yamamoto S, Watabe H, Kanai Y, Aoki M, Sugiyama E, Watabe T, Imaizumi M, Shimosegawa E, Hatazawa J.
    • Journal Title

      Phys Med Biol

      Volume: 56(13) Pages: 4147-4159

    • Related Report
      2011 Final Research Report
    • Peer Reviewed
  • [Journal Article] Interference between PET and MRI sub-systems in a silicon-photomultiplier-based PET/MRI system2011

    • Author(s)
      Yamamoto S, Watabe H, Kanai Y, Aoki M, Sugiyama E, Watabe T, Imaizumi M, Shimosegawa E, Hatazawa J
    • Journal Title

      Phys Med Biol

      Volume: 56-13 Issue: 13 Pages: 4147-59

    • DOI

      10.1088/0031-9155/56/13/026

    • Related Report
      2011 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Diagnostic value of FDG-PET for lymph node metastasis and outcome of surgery for biliary cancer.2011

    • Author(s)
      Kobayashi S, et al.
    • Journal Title

      J Surg Oncol

      Volume: 103(3) Pages: 223-229

    • Related Report
      2010 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Design and performance from an integrated PET/ MRI system for small animals2010

    • Author(s)
      Yamamoto S, Imaizumi M, Kanai Y, Tatsumi M, Aoki M, Sugiyama E, Kawakami M, Shimosegawa E, Hatazawa J.
    • Journal Title

      Ann Nucl Med

      Volume: 24(2) Pages: 89-98

    • NAID

      10026390630

    • Related Report
      2011 Final Research Report
    • Peer Reviewed
  • [Journal Article] A compact and high sensitivity positron detector using dual-layer thin GSo scintillators for a small PET blood sampling system.2010

    • Author(s)
      Yamamoto S, et al.
    • Journal Title

      Phys Med Biol

      Volume: 55(13) Pages: 3813-3826

    • Related Report
      2010 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Development of a Si-PM-based high-resolution PET system for small animals.2010

    • Author(s)
      Yamamoto S, et al.
    • Journal Title

      Phys Med Biol

      Volume: 55(19) Pages: 5817-5831

    • Related Report
      2010 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Global cerebral hypoperfusion in preclinical stage of idiopathic normal pressure hydrocephalus.2010

    • Author(s)
      Takaya M, et al.
    • Journal Title

      J Neurol Sci

      Volume: 298(1-2) Pages: 35-41

    • Related Report
      2010 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Design and performance from an integrated PET/MRI system for small animals.2010

    • Author(s)
      Yamamoto S, et al.
    • Journal Title

      Ann Nucl Med. 24

      Pages: 89-98

    • Related Report
      2009 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Simultaneous imaging of magnetic resonance imaging and positron emission tomography by means of MRI-compatible optic fiber-based PET : a validation study in ex vivo rat brain2009

    • Author(s)
      Imaizumi M, Yamamoto S, Kawakami M, Aoki M, Sugiyama E, Kanai Y, Shimosegawa E, Hatazawa J.
    • Journal Title

      Jpn J Radiol

      Volume: 27(6) Pages: 252-256

    • NAID

      50007286615

    • Related Report
      2011 Final Research Report
    • Peer Reviewed
  • [Journal Article] Simultaneous imaging of magnetic resonance imaging and positron emission tomography by means of MRI-compatible optic fiber based PET : a validation study in ex vivo rat brain2009

    • Author(s)
      Imaizumi M, et al.
    • Journal Title

      Jpn J Radiol 27

      Pages: 252-256

    • Related Report
      2009 Annual Research Report
    • Peer Reviewed
  • [Presentation] PET/MRI一体型装置によるラット脳血流定量評価2011

    • Author(s)
      渡部直史、下瀬川恵久、渡部浩司, 他
    • Organizer
      第51回日本核医学会学術総会
    • Place of Presentation
      つくば国際会議場(茨城県)
    • Year and Date
      2011-10-28
    • Related Report
      2011 Annual Research Report
  • [Presentation] Development of a flexible optical fiber based high resolution integrated PET/MRI system : iPET/MRI II2011

    • Author(s)
      Yamamoto S, Aoki M, SugiyamaE, et al
    • Organizer
      Society of Nuclear Medicine's 58th Annual Meeting
    • Place of Presentation
      San Antonio Convention Center, U.S.A.
    • Year and Date
      2011-06-07
    • Related Report
      2011 Annual Research Report
  • [Presentation] Imaging of cerebral oxygen metabolism in the rat brain : An integrated PET/MRI study with ^<15>O-labelled gas2011

    • Author(s)
      Watabe T, Shimosegawa E, Kanai Y, et al
    • Organizer
      Society of Nuclear Medicine's 58th Annual Meeting
    • Place of Presentation
      San Antonio Convention Center, U.S.A.
    • Year and Date
      2011-06-06
    • Related Report
      2011 Annual Research Report
  • [Presentation] PET/ MRI一体型装置によるラット脳血流定量評価2011

    • Author(s)
      渡部直史、下瀬川恵久、渡部浩司、他
    • Organizer
      第51回日本核医学会学術総会
    • Place of Presentation
      つくば市、つくば国際会議場
    • Related Report
      2011 Final Research Report
  • [Presentation] Development of a flexible optical fiber based high resolution integrated PET/ MRI system : iPET/ MRI II2011

    • Author(s)
      Yamamoto S, Aoki M, Sugiyama E, Watabe H, Watabe T, Kanai Y, Imaizumi M, Shimosegawa E, Hatazawa J.
    • Organizer
      Society of Nuclear Medicine' s 58th Annual Meeting
    • Place of Presentation
      San Antonio, Texas, USA
    • Related Report
      2011 Final Research Report
  • [Presentation] Imaging of cerebral oxygen metabolism in the rat brain : An integrated PET/ MRI study with^15<O>-labelled gas2011

    • Author(s)
      Watabe T, Shimosegawa E, Kanai Y, Watabe H, Imaizumi M, Yamamoto S, Kato H, Tatsumi M, Hatazawa J.
    • Organizer
      Society of Nuclear Medicine' s 58th Annual Meeting
    • Place of Presentation
      San Antonio, Texas, USA
    • Related Report
      2011 Final Research Report
  • [Presentation] Validation of CT attenuation correction for the quantitative SPECT-CBF image reconstruction : A comparative study with O-15 water PET.2010

    • Author(s)
      Shimosegawa E, et al.
    • Organizer
      Society of Nuclear Medicine's 57th Annual Meeting
    • Place of Presentation
      Salt Lake City, Utah, USA
    • Related Report
      2010 Annual Research Report
  • [Presentation] Validation of zero and 1% residual cerebral blood flow measurement by means of SPECT and Tc-99m pertechnetate solution : A phantom study.2010

    • Author(s)
      Fujino K, et al.
    • Organizer
      Society of Nuclear Medicine's 57th Annual Meeting
    • Place of Presentation
      Salt Lake City, Utah, USA
    • Related Report
      2010 Annual Research Report
  • [Presentation] Cerebral glucose metabolism immediately after traumatic brain injury in rats : An integrated PET/MRI study.2010

    • Author(s)
      Imaizumi M, et al.
    • Organizer
      Society of Nuclear Medicine's 57th Annual Meeting
    • Place of Presentation
      Salt Lake City, Utah, USA
    • Related Report
      2010 Annual Research Report
  • [Presentation] Astrocyte specific energy metabolism in humans studied with C-11 acetate and PET : A comparison with F-18 fluoro-deoxy-glucose (FDG).2010

    • Author(s)
      Hatazawa J, et al.
    • Organizer
      Society of Nuclear Medicine's 57th Annual Meeting
    • Place of Presentation
      Salt Lake City, Utah, USA
    • Related Report
      2010 Annual Research Report
  • [Presentation] Pharmacokinetic study of C-11 donepezil in rats measured by planar positron imaging system : A correlation between micro-dose and therapeutic dose distribution.2010

    • Author(s)
      Shimosegawa E, et al.
    • Organizer
      Society of Nuclear Medicine's 57th Annual Meeting
    • Place of Presentation
      Salt Lake City, Utah, USA
    • Related Report
      2010 Annual Research Report
  • [Presentation] Integrated PET/ MRI(iPET/ MRI) for small animals : Performance characteristics and initial experiences2009

    • Author(s)
      Shimosegawa E, Yamamoto S, Imaizumi M, Kanai Y, Tatsumi M, Masaaki Aoki, Sugiyama E, Hatazawa J
    • Place of Presentation
      Barcelona, Spain
    • Related Report
      2011 Final Research Report
  • [Presentation] Simultaneous 11C-methionine (MET) PET and contrast-enhanced (CE) MR rat imaging with an integrated PETIMRI system : Initial experience2009

    • Author(s)
      Tatsumi M, et al.
    • Organizer
      Society of Nuclear Medicine's 56th Annual Meeting
    • Place of Presentation
      Toronto, Canada
    • Related Report
      2009 Annual Research Report
  • [Presentation] Development of an integrated PET/MRI (iPET/MRI) system for small animals2009

    • Author(s)
      Yamamoto S, et al.
    • Organizer
      Society of Nuclear Medicine's 56th Annual Meeting
    • Place of Presentation
      Toronto, Canada
    • Related Report
      2009 Annual Research Report
  • [Presentation] In vivo small animal simultaneous measurements using integrated PET/MRI (iPET/MRI) system with ^<18>F-FDG2009

    • Author(s)
      Imaizumi M, et al.
    • Organizer
      Society of Nuclear Medicine's 56th Annual Meeting
    • Place of Presentation
      Toronto, Canada
    • Related Report
      2009 Annual Research Report
  • [Presentation] Integrated PET/MRI (iPET/MRI) for small animals : Performance characteristics and initial experiences2009

    • Author(s)
      Shimosegawa E, et al.
    • Organizer
      European Association of Nuclear Medicine 2009
    • Place of Presentation
      Barcelona, Spain
    • Related Report
      2009 Annual Research Report
  • [Remarks]

    • URL

      http://www.med.osaka-u.ac.jp/pub/tracer/index-jp.htm

    • Related Report
      2011 Final Research Report
  • [Remarks]

    • URL

      http://www.med.osaka-u.ac.jp/pub/tracer/index-jp.htm

    • Related Report
      2011 Annual Research Report
  • [Remarks]

    • URL

      http://www.med.osaka-u.ac.jp/pub/tracer/index-jp.htm

    • Related Report
      2010 Annual Research Report

URL: 

Published: 2009-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi