• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Development of Compton imaging method toward quantification of astatine-211 therapy imaging

Research Project

Project/Area Number 21K15855
Research Category

Grant-in-Aid for Early-Career Scientists

Allocation TypeMulti-year Fund
Review Section Basic Section 52040:Radiological sciences-related
Research InstitutionNational Institutes for Quantum Science and Technology

Principal Investigator

長尾 悠人  国立研究開発法人量子科学技術研究開発機構, 高崎量子応用研究所 先進ビーム利用施設部, 主任技術員 (60622545)

Project Period (FY) 2021-04-01 – 2025-03-31
Project Status Granted (Fiscal Year 2023)
Budget Amount *help
¥4,550,000 (Direct Cost: ¥3,500,000、Indirect Cost: ¥1,050,000)
Fiscal Year 2024: ¥1,560,000 (Direct Cost: ¥1,200,000、Indirect Cost: ¥360,000)
Fiscal Year 2023: ¥1,040,000 (Direct Cost: ¥800,000、Indirect Cost: ¥240,000)
Fiscal Year 2022: ¥910,000 (Direct Cost: ¥700,000、Indirect Cost: ¥210,000)
Fiscal Year 2021: ¥1,040,000 (Direct Cost: ¥800,000、Indirect Cost: ¥240,000)
Keywordsコンプトンカメラ / 標的アイソトープ治療 / RI内用療法 / 核医学治療 / アスタチン211 / At-211
Outline of Research at the Start

体内に投与した核医学治療用アスタチン(At-211)薬剤分布の可視化では、現在、SPECT法を利用せざるを得ないが、計測対象である低エネルギーX線の減弱が影響し、定量性の高い画像の取得には限界がある。申請者はこの限界を突破するため、減弱を受けにくい高エネルギーガンマ線を計測対象とした「コンプトンカメラ」の研究を開始したが、SPECT法の計測対象であった低エネルギーX線由来の高カウントレートノイズが定量化の障壁となることが分かった。本研究では、At-211画像の定量化を目的として、この課題を解決するための吸収体を提案し、その効果を実験により実証する。

Outline of Annual Research Achievements

体内に投与した核医学治療用アスタチン211薬剤分布の可視化においては、現在、SPECT法を利用せざるを得ないが、計測対象である低エネルギーエックス線の減弱や散乱が影響し、臓器内のアスタチン211濃度を正確に求められるほど定量性の高い画像を取得することは困難である。本研究代表者らはこの限界を突破するため、減弱の影響を受けにくい高エネルギーガンマ線に着目し、高エネルギーガンマ線を計測対象とした「コンプトンカメラ」の開発に着手し、試作したコンプトンカメラを用いてアスタチン211点様線源のイメージングに成功した。しかしながら、アスタチン211のコンプトンイメージングにおいては、SPECT法の計測対象であった低エネルギーエックス線由来の高カウントレートノイズが定量化の大きな障壁となることがこれまでの研究で明らかになってきた。
令和5年度は、令和4年度にモンテカルロシミュレータを開発して実施した前段検出器の拡張(大型化)等の改良について、前段検出器の有効面積の算出方法を中心にさらに検討を進めた。その結果、後段検出器の有効面積はそのままに、前段検出器の光検出器の大型化を実施することで、感度が改良前のコンプトンカメラと比較して約3倍、令和4年度の検討結果と比較しても1.5倍以上向上する見込みとなることが分かった。さらに、前段検出器のシンチレータについても大型化を実施することで、感度が更に約3倍向上する見込みとなることが分かった。

Current Status of Research Progress
Current Status of Research Progress

3: Progress in research has been slightly delayed.

Reason

当初計画していたシミュレータの精密化が計画通りに進まなかったため。

Strategy for Future Research Activity

引き続きシミュレータの精密化を進めるともに、前段検出器の光検出器及びシンチレータの大型化を実施する。

Report

(3 results)
  • 2023 Research-status Report
  • 2022 Research-status Report
  • 2021 Research-status Report
  • Research Products

    (4 results)

All 2023 2022 2021

All Journal Article (3 results) (of which Int'l Joint Research: 2 results,  Peer Reviewed: 3 results,  Open Access: 2 results) Presentation (1 results) (of which Int'l Joint Research: 1 results)

  • [Journal Article] Evaluation and optimization of geometry parameters of GAGG scintillator-based Compton Camera for medical imaging by Monte Carlo simulation2023

    • Author(s)
      Zarei H.、Razaghi S.、Nagao Y.、Itoh M.、Yamaguchi M.、Kawachi N.、Ay M.R.、Watabe H.
    • Journal Title

      Journal of Instrumentation

      Volume: 18 Issue: 01 Pages: P01035-P01035

    • DOI

      10.1088/1748-0221/18/01/p01035

    • Related Report
      2022 Research-status Report
    • Peer Reviewed / Open Access / Int'l Joint Research
  • [Journal Article] The performance study of developed cost-effective Compton Camera based on Ce:GAGG scintillator using experimental measurements and CCMod of GATE simulation module2022

    • Author(s)
      Zarei Hajar、Nagao Yuto、Yamamoto Kohei、Itoh Masatoshi、Yamaguchi Mitsutaka、Kawachi Naoki、Watabe Hiroshi
    • Journal Title

      Journal of Instrumentation

      Volume: 17 Issue: 10 Pages: P10012-P10012

    • DOI

      10.1088/1748-0221/17/10/p10012

    • Related Report
      2022 Research-status Report
    • Peer Reviewed / Int'l Joint Research
  • [Journal Article] Performance improvement of Compton imaging of astatine-211 by optimising coincidence time windows2021

    • Author(s)
      Nagao Y.、Yamaguchi M.、Watanabe S.、Ishioka N.S.、Kawachi N.、Watabe H.
    • Journal Title

      Journal of Instrumentation

      Volume: 16 Issue: 12 Pages: C12031-C12031

    • DOI

      10.1088/1748-0221/16/12/c12031

    • Related Report
      2021 Research-status Report
    • Peer Reviewed / Open Access
  • [Presentation] Performance improvement of Compton imaging of astatine-211 by optimizing coincidence time window2021

    • Author(s)
      Nagao Yuto、Yamaguchi Mitsutaka、Watanabe Shigeki、Ishioka Noriko S.、Kawachi Naoki、Watabe Hiroshi
    • Organizer
      22nd International Workshop on Radiation Imaging Detectors
    • Related Report
      2021 Research-status Report
    • Int'l Joint Research

URL: 

Published: 2021-04-28   Modified: 2024-12-25  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi