Research on the rapid measurement of stability of a refrigerant having low global warming potential
Project/Area Number |
22510094
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
Environmental technology/Environmental materials
|
Research Institution | 群馬県立群馬産業技術センター (2012) Gunma Prefectural Industrial Technology Center (2010-2011) |
Principal Investigator |
SUZUKI Takashi 群馬県立群馬産業技術センター, 主任研究員 (40196837)
|
Co-Investigator(Kenkyū-buntansha) |
KATSUTA Masafumi 早稲田大学, 理工学部, 教授 (20120107)
TAJIMA So 群馬県立産業技術センター, 独立研究員 (30469887)
YAMAMOTO Ryoichi 群馬県立産業技術センター, 主任研究員 (40469888)
|
Project Period (FY) |
2010 – 2012
|
Project Status |
Completed (Fiscal Year 2012)
|
Budget Amount *help |
¥4,420,000 (Direct Cost: ¥3,400,000、Indirect Cost: ¥1,020,000)
Fiscal Year 2012: ¥650,000 (Direct Cost: ¥500,000、Indirect Cost: ¥150,000)
Fiscal Year 2011: ¥910,000 (Direct Cost: ¥700,000、Indirect Cost: ¥210,000)
Fiscal Year 2010: ¥2,860,000 (Direct Cost: ¥2,200,000、Indirect Cost: ¥660,000)
|
Keywords | 環境負荷低減技術 / 、低環境負荷冷媒 / 冷媒新規計測法 / 環境保全 / 低GWP冷媒 / 2,3,3,3-テトラフルオロプロピレン / 安定性迅速計測 / 強制循環式計測技術 / 2,3,3,3-テトラフルオロプロペン |
Research Abstract |
So far the evaluation of stability regarding refrigerants has been carried out by ANSI-ASHRAE method. A metal specimen and a refrigerant are set in glass made shield tube and these are maintained statically for about 5 ~ 10 days to obtain stability results by the method. Contrary to the conventional method, in this work, a refrigerant was circulating continuously onto high dispersed type metal specimen by using closed circulating system, and as a result, the relative stability of the refrigerant having low GWP (global warming potential) like R-1234yf (2,3,3,3-tetrafluoropropylene) and R-134a (1,1,1,2-tetrafluoroethane) was obtained within several hours. It was conjectured that decomposition of R-1234yf was enhanced on nickel and aluminum metal species but was suppressed on copper metal species. In addition, the formation of hydrogen fluoride was suggested during the decomposition of R-1234yf in the presence of metals like aluminum. Thus the short term measurement for the stability of refrigerants showing low GWP was successfully achieved.
|
Report
(4 results)
Research Products
(12 results)
-
-
-
[Presentation]2012
Author(s)
鈴木 崇,小松俊二,〓 相哲、勝田正文
Organizer
2012 年度日本冷凍空調学会年次大会
Place of Presentation
札幌
Related Report
-
-
-
-
-
[Presentation]
Author(s)
鈴木 崇,小松俊二,〓 相哲、勝田正文
Organizer
2011 年度日本冷凍空調学会年次大会
Place of Presentation
東京