The optimal eco-aseismic retrofitting method of the existing disqualified building by the rooftop gardening system which served as vibration control equipment
Project/Area Number |
22510183
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
Social systems engineering/Safety system
|
Research Institution | Shibaura Institute of Technology |
Principal Investigator |
|
Project Period (FY) |
2010 – 2012
|
Project Status |
Completed (Fiscal Year 2012)
|
Budget Amount *help |
¥4,420,000 (Direct Cost: ¥3,400,000、Indirect Cost: ¥1,020,000)
Fiscal Year 2012: ¥1,040,000 (Direct Cost: ¥800,000、Indirect Cost: ¥240,000)
Fiscal Year 2011: ¥1,040,000 (Direct Cost: ¥800,000、Indirect Cost: ¥240,000)
Fiscal Year 2010: ¥2,340,000 (Direct Cost: ¥1,800,000、Indirect Cost: ¥540,000)
|
Keywords | 都市・社会防災 / 地球環境 / 耐震性能 / 耐震補強 / 地球環境問題 / ヒートアイランド現象 / 屋上庭園 / 制震装置 / ピロティー建物 / 剛性率 / 偏心率 / 既存不適格建物 / 屋上緑化 / 地震力低減 / 偏心率低減 |
Research Abstract |
For the existing disqualified building, we verified whether or not the rooftop garden system with vibration control equipment solves both the heat island effect and the earthquake-proof performance, by the seismic response analysis using various parameters. As a result, depending on building, in case that lack of bearing force is less about 20%, even if it did not perform antiseismic reinforcement, we checked that there was an optimal eco-aseismic retrofitting method that secured earthquake-proof performance.On the other hand, in case of admissible building, we showed that a rooftop garden could be installed without reinforcing.
|