STRUCTURAL PERFORMANCE OF SHORT COLUMNS FOR NEWLY DESIGNED REINFORCED CONCRETE BUILDINGS
Project/Area Number |
22760422
|
Research Category |
Grant-in-Aid for Young Scientists (B)
|
Allocation Type | Single-year Grants |
Research Field |
Building structures/materials
|
Research Institution | Niigata University (2011-2012) Tokyo Metropolitan University (2010) |
Principal Investigator |
|
Project Period (FY) |
2010 – 2012
|
Project Status |
Completed (Fiscal Year 2012)
|
Budget Amount *help |
¥4,290,000 (Direct Cost: ¥3,300,000、Indirect Cost: ¥990,000)
Fiscal Year 2012: ¥650,000 (Direct Cost: ¥500,000、Indirect Cost: ¥150,000)
Fiscal Year 2011: ¥1,950,000 (Direct Cost: ¥1,500,000、Indirect Cost: ¥450,000)
Fiscal Year 2010: ¥1,690,000 (Direct Cost: ¥1,300,000、Indirect Cost: ¥390,000)
|
Keywords | 鉄筋コンクリート建物 / 短柱 / せん断破壊 / 崩壊 / 構造設計 / 軸力減少 / 層崩壊 / 崩壊変形 / 主筋比 / せん断補強筋比 |
Research Abstract |
Structural performance of short columns for newly designed reinforced concrete buildings was studied. The major findings from the study are as follows: (1) collapse drift of shear-failing RC column tends to be large as the main reinforcement ratio increases. This finding may indicate that column with shear failure mode could be used for structural design; and (2) columns for which axial load was decreased below the initial level showed larger collapse drift than columns for which axial load was kept constant, and as the greater the rate of axial load decrease, the larger the collapse drift.
|
Report
(4 results)
Research Products
(6 results)