Research on haptic glove remote interactions for international communication of deafblind
Project/Area Number |
22K12125
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Multi-year Fund |
Section | 一般 |
Review Section |
Basic Section 61020:Human interface and interaction-related
|
Research Institution | Shizuoka University |
Principal Investigator |
Kamen Kanev 静岡大学, 電子工学研究所, 教授 (60404894)
|
Co-Investigator(Kenkyū-buntansha) |
中村 篤志 静岡大学, 電子工学研究所, 准教授 (50402243)
|
Project Period (FY) |
2022-04-01 – 2025-03-31
|
Project Status |
Granted (Fiscal Year 2022)
|
Budget Amount *help |
¥4,160,000 (Direct Cost: ¥3,200,000、Indirect Cost: ¥960,000)
Fiscal Year 2024: ¥390,000 (Direct Cost: ¥300,000、Indirect Cost: ¥90,000)
Fiscal Year 2023: ¥1,300,000 (Direct Cost: ¥1,000,000、Indirect Cost: ¥300,000)
Fiscal Year 2022: ¥2,470,000 (Direct Cost: ¥1,900,000、Indirect Cost: ¥570,000)
|
Keywords | deafblind communication / mobile touch input / haptic data glove / コミュニケーションインターフェース |
Outline of Research at the Start |
本研究は、盲ろう者との遠隔双方向コミュニケーションを実現するためのインターフェースであるハプティックグローブの提案と、異なる言語圏での実装したハプティックグローブのシステム評価を行い、盲ろう者の自立支援のためのヒューマンインターフェースを開発するものである。
|
Outline of Annual Research Achievements |
An extensive review of different technologies for touch based input and haptic feedback has been conducted. In result, contact-based input employing metalized touch pads has been selected as a basis for the message input data glove. With respect to the message receiving data glove, thin circular piezoelectric actuators sized between 8mm and 12 mm in diameter have been identified as good candidates for the initial implementation. Extensive experiments have been conducted to identify the optimal controls such as voltages and frequencies necessary for producing the desirable haptic effects. An integrated control system, consisting of two microcontroller boards, a functional signal generator, a specialized piezo drive amplifier, and relay modules have been designed for connecting the two data gloves and conducting experiments. The results obtained during the current fiscal year have been reported at research meetings and symposiums and published in the Institute of Image Information and Television Engineers (ITE) and Institute of Electronics, Information and Communication Engineers (IEICE) technical report series. More extensive coverage of the research achievements is provided in a paper accepted for presentation at the 17th International Conference on Innovative Mobile and Internet Services in Ubiquitous Computing (IMIS-2023) and publication in a conference proceedings book by Springer.
|
Current Status of Research Progress |
Current Status of Research Progress
2: Research has progressed on the whole more than it was originally planned.
Reason
Initial prototypes of both, the message receiving and the message sending data gloves have been developed and interconnected through a specially designed integrated control system. Since the initial system has been implemented as a proof-of-concept, efficiency, reliability, and usability issues have not be considered in full. Indeed, while some preliminary experiments have been successfully conducted with the initially developed system, it has become clear that more robust versions of the data gloves as well as of the integrated control system will be necessary. The required redesign may thus involve research and investigation of new materials and components for the data gloves, testing and selection of more advanced microcontrollers, and development of control and communication software with more advanced functionality.
|
Strategy for Future Research Activity |
We are planning to continue with implementing a new, more robust version of the message sending and the message receiving data gloves. Novel materials such as conductive threads and fabric as well as pressure sensitive materials will be considered and experimented with for the implementation of the input functionality of the message sending data glove. With respect to the message receiving data glove, piezoelectric materials with improved feedback will be investigated and considered for employment. A compact data gloves control system, suitable for mobile use and incorporating the functionality of a signal generator, a dedicated piezo drive amplifier, an input multiplexor, and an output, high-voltage AC multiplexor for actuator switching will be designed and implemented. Finally, a more advanced microcontroller, matching the needs of the added hardware will be selected and a functionally enhanced version of the control software, suitable for the chosen microcontroller will be developed.
|
Report
(1 results)
Research Products
(7 results)
-
-
-
-
-
[Presentation] Mixed Reality and AI-based Data Glove in Post-Traumatic Hand Recovery2022
Author(s)
Fung, B., Hung, P., Padilla, C., Martinez, M.A., Tokuhiro, A., Uribe-Quevedo, A., Kanev, K., Mimura, H., Kimura, M.
Organizer
The 7th International Symposium on Biomedical Engineering ISBE2022
Related Report
-
[Presentation] Augmented Data Glove for Advanced Hand and Finger Motion Interactions2022
Author(s)
Fung, B., Hung, P., Velasco, C., Cano, M., Tokuhiro, A., Urive-Quevedo, A., Kanev, K., Kimura, M., Mimura, H.
Organizer
Achievements Report Meeting 2022, Tokyo Institute of Technology, Yokohama-city, Japan
Related Report
-