Establishment of shield scan method for dose reduction of mammary gland in CT screening for lung cancer

Research Project

Project/Area Number 23791384
Research Category

Grant-in-Aid for Young Scientists (B)

Allocation TypeMulti-year Fund
Research Field Radiation science
Research InstitutionHirosaki University

Principal Investigator

OSANAI Minoru  弘前大学, 保健学研究科, 助教 (40514138)

Project Period (FY) 2011 – 2013
Project Status Completed (Fiscal Year 2013)
Budget Amount *help
¥3,120,000 (Direct Cost: ¥2,400,000、Indirect Cost: ¥720,000)
Fiscal Year 2013: ¥910,000 (Direct Cost: ¥700,000、Indirect Cost: ¥210,000)
Fiscal Year 2012: ¥780,000 (Direct Cost: ¥600,000、Indirect Cost: ¥180,000)
Fiscal Year 2011: ¥1,430,000 (Direct Cost: ¥1,100,000、Indirect Cost: ¥330,000)
KeywordsCT検査 / CT肺がん検診 / 医療被ばく / 被ばく低減 / 遮蔽撮影 / CT検査 / CT肺がん検診
Research Abstract

This study aimed to clarify the material of shield that enables radiation dose reduction of mammary gland without severe degradation of image quality in CT screening for lung cancer. It distributes to the establishment of shield CT scan method. Some metal plates (copper, zinc, molybdenum and stainless) and sheets (rubber sheet and bismuth-contained sheet) were selected as a shield. The metal plates and sheets were placed over the phantom. The CT scan was performed, and radiation dose and image quality were assessed. The relationship between radiation dose reduction rate and image quality in each shield was investigated. It was suggested that shield scan method was useful, and zinc and copper is suitable for shield scan.

Report

(4 results)
  • 2013 Annual Research Report   Final Research Report ( PDF )
  • 2012 Research-status Report
  • 2011 Research-status Report
  • Research Products

    (2 results)

All 2013 2012

All Journal Article (2 results) (of which Peer Reviewed: 1 results)

  • [Journal Article] Image quality and radiation dose with low tube voltage in coronary CT angiography: an experimental study with normal type and soft plaque phantom2013

    • Author(s)
      Osanai M, Saito Y, Oyu K, Ishida J, Sato M, Sasaki T
    • Journal Title

      Hirosaki Medical Journal

      Volume: 64(1) Pages: 15-28

    • NAID

      110009614111

    • Related Report
      2013 Annual Research Report 2013 Final Research Report
    • Peer Reviewed
  • [Journal Article] 医療被ばく低減に向けて~ CT検査における対策~2012

    • Author(s)
      小山内暢,齋藤陽子,細川洋一郎
    • Journal Title

      ESI-NEWS

      Volume: 30(2) Pages: 1-6

    • Related Report
      2013 Final Research Report