Fundamental examinations on the safety of intensity modulated radiotherapy under moving conditions
Project/Area Number |
23791408
|
Research Category |
Grant-in-Aid for Young Scientists (B)
|
Allocation Type | Multi-year Fund |
Research Field |
Radiation science
|
Research Institution | Kyoto University |
Principal Investigator |
|
Project Period (FY) |
2011 – 2013
|
Project Status |
Completed (Fiscal Year 2013)
|
Budget Amount *help |
¥4,160,000 (Direct Cost: ¥3,200,000、Indirect Cost: ¥960,000)
Fiscal Year 2013: ¥1,040,000 (Direct Cost: ¥800,000、Indirect Cost: ¥240,000)
Fiscal Year 2012: ¥1,170,000 (Direct Cost: ¥900,000、Indirect Cost: ¥270,000)
Fiscal Year 2011: ¥1,950,000 (Direct Cost: ¥1,500,000、Indirect Cost: ¥450,000)
|
Keywords | 強度変調放射線治療 / 呼吸性移動 |
Research Abstract |
Intensity-modulated RT (IMRT) enables safe radiation dose escalation for targets, without increasing toxicity to the surrounding organs at risk. However, respiratory organ motion can significantly degrade the dosimetric advantage of IMRT due to the interplay between multileaf collimator (MLC) and organ motion. In the current study, phantom and simulation studies showed delivered dose distributions were comparable with calculated ones for targets with respiratory motion of around 10 mm.
|
Report
(4 results)
Research Products
(65 results)
-
-
-
-
-
[Journal Article] A feasibility study on reduction of the entrance-surface dose to neonates by use of a new digital mobile X-ray system2013
Author(s)
Utsunomiya S, Monzen H, Akimoto M, Mukumoto N, Ishihara Y, Shiinoki T, Nakamura M, Miyabe Y, Sato S, Matsuo S, Hiraoka M.
-
Journal Title
Radiol Phys Technol.
Volume: 6
Issue: 1
Pages: 157-61
DOI
NAID
Related Report
Peer Reviewed
-
-
-
-
-
[Journal Article] Dose-Volume Metrics Associated With Radiation Pneumonitis After Stereotactic Body Radiation Therapy For Lung Cancer2012
Author(s)
Matsuo Y, Shibuya K, Nakamura M, Narabayashi M, Sakanaka K, Ueki N, Miyagi K, Norihisa Y, Mizowaki T, Nagata Y, Hiraoka M.
-
Journal Title
Int J Radiat Oncol Biol Phys
Volume: 83
NAID
Related Report
Peer Reviewed
-
-
-
-
-
-
-
-
[Journal Article] Guidelines for respiratory motion management in radiation therapy2012
Author(s)
Matsuo Y, Onishi H, Nakagawa K, Nakamura M, Ariji T, Kumazaki Y, Shimbo M, Tohyama N, Nishio T, Okumura M, Shirato H, Hiraoka M.
-
Journal Title
Related Report
Peer Reviewed
-
-
[Journal Article] Dose-volume metrics associated with radiation pneumonitis after stereotactic body radiation therapy for lung cancer.2012
Author(s)
Matsuo Y, Shibuya K, Nakamura M, Narabayashi M, Sakanaka K, Ueki N, Miyagi K, Norihisa Y, Mizowaki T, Nagata Y, Hiraoka M.
-
Journal Title
Int J Radiat Oncol Biol Phys.
Volume: 83(4)
Issue: 4
Pages: e545-e549
DOI
NAID
Related Report
Peer Reviewed
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
[Presentation] Effect of audio instruction on the tracking accuracy for a four-dimensional image-guided radiotherapy system, MHI-TM2000 (VERO)2011
Author(s)
Mitsuhiro Nakamura, Akira Sawada, Nobutaka Mukumoto, Kunio Takahashi, Yuki Miyabe, Kenji Takayama, Yukinori Matsuo, Takashi Mizowaki, Masaki Kokubo, Masahiro Hiraoka
Organizer
52nd AAPM
Place of Presentation
Vancouver Convention Center (Canada)
Related Report
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-