• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Evaluation of 3D distribution of dose and radiation quality for BNCT - Development of whole-body-phantom type phosphor -

Research Project

Project/Area Number 23K07118
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeMulti-year Fund
Section一般
Review Section Basic Section 52040:Radiological sciences-related
Research InstitutionKyoto Pharmaceutical University

Principal Investigator

田中 憲一  京都薬科大学, 薬学部, 教授 (70363075)

Project Period (FY) 2023-04-01 – 2026-03-31
Project Status Granted (Fiscal Year 2023)
Budget Amount *help
¥4,810,000 (Direct Cost: ¥3,700,000、Indirect Cost: ¥1,110,000)
Fiscal Year 2025: ¥650,000 (Direct Cost: ¥500,000、Indirect Cost: ¥150,000)
Fiscal Year 2024: ¥780,000 (Direct Cost: ¥600,000、Indirect Cost: ¥180,000)
Fiscal Year 2023: ¥3,380,000 (Direct Cost: ¥2,600,000、Indirect Cost: ¥780,000)
Keywords中性子捕捉療法 / 蛍光体 / 線量 / 線質 / 波長特性 / ホウ素中性子捕捉療法 / 輝尽蛍光体 / 3次元分布
Outline of Research at the Start

ホウ素中性子捕捉療法(BNCT)の成分ごとの線量、そして線質(線エネルギー付与(LET)および線量成分比)の全身の3次元分布を測定できる手法を確立する。そのため、放射線輸送が人体と等価な全身ファントム兼検出器を開発する。その原理として、申請者が線質測定への応用可能性を示した光刺激蛍光体(イメージングプレート材質)の波長特性を用い、線量と線質を同時に検出する手法を追究する。2次元検出器を積層しての3次元評価を想定する。

Outline of Annual Research Achievements

まず、線質・線量の両方を測定する輝尽蛍光体の第一案として、BaFBr:Euを定法で作成した。これに対し、蛍光量の波長依存性が照射放射線の線質によってどう変化するかを測定した。照射には、γ線照射として京都大学複合原子力科学研究所のコバルト60γ線照射装置と、中性子(γ線混合)照射として京都大学原子炉重水中性子照射設備の基準混合中性子照射モードをレール治具で用いた。その結果、励起スペクトルでは650nm励起での蛍光量に対する630nm励起での蛍光量の比が、γ線照射で1.5~1.7であるのに対し、中性子照射で1.2~1.4と、それぞれの不確かさ10%程度に対し顕著な違いが見られた。蛍光スペクトルでは、452nm蛍光量に対する418nm蛍光量の比がγ線照射で1.5、中性子照射では1.1と、これも顕著な違いが見られた。なお、BaFBr:Euを輝尽蛍光体として用いる市販のイメージングプレート(富士フィルム社、BAS-TR)では、線質による違いがわずかながら不確かさを越えて見られた。具体的には、励起スペクトルで蛍光量比(532nm励起/650nm励起)および蛍光量比(630nm励起/650nm励起)はγ線照射より中性子照射で7%程度低くなった。このとき、それぞれの不確かさは5%程度であった。蛍光スペクトルでは蛍光量比(346nm/389nm)が、不確かさ4%程度に対して中性子照射で10%高くなった。以上の結果は、輝尽蛍光体BaFBr:Euにより線質を測定できることを示唆するものであった。今後、LETを定量的に変化させた際の蛍光量の蛍光・励起波長依存性の取得を継続するが、第一案としてはBaFBr:Euを用いる場合を想定して、検討を進めることとした。
加えて、蛍光の2次元読み出し系の構築を開始した。本予算で波長依存性を取得できるCMOSカメラを導入した。まずは単色光源と合わせて、読み出し系の構築と像読み出しの試行を行う予定である。

Current Status of Research Progress
Current Status of Research Progress

2: Research has progressed on the whole more than it was originally planned.

Reason

当初計画した測定がやや遅れているものの、2次元の読み取り装置は計画より進んでおり、総じて、おおむね順調と判断した。

Strategy for Future Research Activity

まず軟組織の検出器について、設計と作成・性能評価を行う予定である。並行して、2次元読み取り系の性能評価を行う。

Report

(1 results)
  • 2023 Research-status Report
  • Research Products

    (4 results)

All 2023

All Journal Article (3 results) (of which Int'l Joint Research: 1 results,  Peer Reviewed: 1 results,  Open Access: 1 results) Presentation (1 results)

  • [Journal Article] Strength estimation for moving iodine-125 source for brachytherapy: application to source link loader2023

    • Author(s)
      K.Tanaka, T.Kajimoto, O.Asanuma, M.Hori, K.Kamo, T.Suzuki, I.Sumida, Y.Takahashi, G.Bengua, K.Sakata, S.Endo,
    • Journal Title

      京都薬科大学紀要

      Volume: 4 Issue: 2 Pages: 167-174

    • DOI

      10.34445/0002000071

    • ISSN
      2435-4112
    • URL

      https://kyoto-phu.repo.nii.ac.jp/records/2000071

    • Year and Date
      2023-12-07
    • Related Report
      2023 Research-status Report
    • Peer Reviewed / Open Access / Int'l Joint Research
  • [Journal Article] Development of strength evaluation method of moving sources for brachytherapy (5) application to source link loader2023

    • Author(s)
      K. Tanaka, T. Kajimoto, O. Asanuma, M. Hori, K. Kamo, T. Suzuki, I. Sumida, Y. Takahashi, G. Bengua, K. Sakata, S. Endo
    • Journal Title

      Japanese Journal of Medical Physics

      Volume: 43 Sup3 Pages: 154-154

    • Related Report
      2023 Research-status Report
  • [Journal Article] Preliminary survey of nuclide for epithermal neutron measurement using gel detector2023

    • Author(s)
      K.Tanaka, Y.Sakurai, T.Kajimoto, H.Tanaka, T.Takata, S.Endo
    • Journal Title

      KURNS Progress Report

      Volume: 2022 Pages: 21-21

    • Related Report
      2023 Research-status Report
  • [Presentation] 小線源治療のための移動中線源強度評価法の開発(5)線源連結装置への適用」ポスター)2023

    • Author(s)
      田中憲一、梶本剛、浅沼治、堀正和、加茂憲一、鈴木健史、隅田伊織、高橋豊、G.Bengua、坂田耕一、遠藤曉
    • Organizer
      第124回日本医学物理学会学術大会(2023.9.15-17)広島(
    • Related Report
      2023 Research-status Report

URL: 

Published: 2023-04-13   Modified: 2024-12-25  