Outline of Final Research Achievements |
As a system using a conventional unidirectional air turbine in oscillating water column (OWC) based on a wave energy plant, a twin unidirectional impulse turbine topology has been suggested in previous studies. The performances of a unidirectional impulse turbine under steady flow conditions were investigated experimentally by using a wind tunnel in this study. Then, mean efficiency of the twin impulse turbine in bidirectional airflow has been estimated by a quasi-steady analysis using experimental results in order to propose the suitable turbine geometry on the performance. On the other hand, the mean efficiency is considerably lower than the efficiency under steady flow condition because reciprocating air flow can’t be rectified adequately by a unidirectional turbine. In order to improve the efficiency, using fluidic diode is discussed. In this study, two different fluidic diodes were discussed by CFD and a wind tunnel test.
|