Budget Amount *help |
¥5,460,000 (Direct Cost: ¥4,200,000、Indirect Cost: ¥1,260,000)
Fiscal Year 2014: ¥1,170,000 (Direct Cost: ¥900,000、Indirect Cost: ¥270,000)
Fiscal Year 2013: ¥1,040,000 (Direct Cost: ¥800,000、Indirect Cost: ¥240,000)
Fiscal Year 2012: ¥3,250,000 (Direct Cost: ¥2,500,000、Indirect Cost: ¥750,000)
|
Outline of Final Research Achievements |
In superconducting magnetic levitation (Maglev) systems, superconducting magnets are located on both sides of the vehicles and ground coils are attached to sidewalls of the guideway; the vehicles are levitated, guided, and propelled over the guideway by the electromagnetic force between them. Because a partial discharge (PD), which is a degradation symptom of insulating resin of the ground coils, emits wideband electromagnetic (EM) waves, a radio sensing system for locating the PD by receiving the EM waves was developed in this study. The experimental results showed that the PD occurring in a ground coil with defects could be located by using the radio sensing system.
|