Development of multiwavelength digital holographic endoprobe system for small pipe inspection using profilometry and spectroscopy

Research Project

Project/Area Number 24560521
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeMulti-year Fund
Section一般
Research Field Measurement engineering
Research InstitutionShimane University

Principal Investigator

YOKOTA Masayuki  島根大学, 総合理工学研究科(研究院), 教授 (80323335)

Project Period (FY) 2012-04-01 – 2015-03-31
Project Status Completed (Fiscal Year 2014)
Budget Amount *help
¥5,330,000 (Direct Cost: ¥4,100,000、Indirect Cost: ¥1,230,000)
Fiscal Year 2014: ¥1,170,000 (Direct Cost: ¥900,000、Indirect Cost: ¥270,000)
Fiscal Year 2013: ¥1,040,000 (Direct Cost: ¥800,000、Indirect Cost: ¥240,000)
Fiscal Year 2012: ¥3,120,000 (Direct Cost: ¥2,400,000、Indirect Cost: ¥720,000)
Keywordsディジタルホログラフィ / 波長多重 / ディジタルホログラフィ内視鏡 / 細管内表面形状計測 / 分光画像 / 直管内計測システム開発 / カラーディジタルホログラフィ / GPGPU / 内視鏡 / 形状計測
Outline of Final Research Achievements

Multiwavelength digital holography for the investigation of a straight pipe inner surface has been proposed. To classify defects on a pipe inner surface, the intensity image reconstructed by three wavelengths (Red, Green and Blue) are used and that enables us to visualize color image of the pipe inner surface. By using the spectral reflectance obtained by each intensity image, it is possible to classify crack and verdigris in the pipe inner surface.
In addition, the height profile of the pipe inner surface could be obtained by two-wavelength holographic contouring technique. Object having a thickness of 0.1mm could be detected using the technique. For the measurement using a cone-shaped mirror, the inclination and positional error of the mirror becomes problem. The algorithm for correcting the effect brought by such error has been proposed and has been shown that the error can be effectively reduced using the correction process using the proposed algorithm.

Report

(4 results)
  • 2014 Annual Research Report   Final Research Report ( PDF )
  • 2013 Research-status Report
  • 2012 Research-status Report
  • Research Products

    (26 results)

All 2015 2014 2013 2012 Other

All Journal Article (3 results) (of which Peer Reviewed: 3 results,  Acknowledgement Compliant: 1 results) Presentation (20 results) (of which Invited: 1 results) Remarks (3 results)

  • [Journal Article] Digital holographic inspection for the inner surface of a straight pipe using current-induced multiwavelength from two laser diodes2014

    • Author(s)
      M. Yokota, T. Koyama, and T. Kawakami
    • Journal Title

      Optical Engineering

      Volume: 53

    • Related Report
      2014 Annual Research Report
    • Peer Reviewed / Acknowledgement Compliant
  • [Journal Article] 位相シフトディジタルホログラフィーにおけるプラスチック光ファイバー(POF)イメージガイドを用いたホログラム伝送の検討2013

    • Author(s)
      横田正幸,河尻直幸
    • Journal Title

      光学

      Volume: 42 Pages: 144-152

    • Related Report
      2013 Research-status Report
    • Peer Reviewed
  • [Journal Article] 位相シフトディジタルホログラフィにおけるプラスチック光ファイバーイメージガイドを用いたホログラム伝送の検討2013

    • Author(s)
      横田正幸,河尻直幸
    • Journal Title

      光学

      Volume: 42 Pages: 144-152

    • NAID

      10031154887

    • Related Report
      2012 Research-status Report
    • Peer Reviewed
  • [Presentation] ホログラフィック内視鏡における円錐鏡の軸ずれと傾きにより発生する誤差の補正2015

    • Author(s)
      竹田和史,横田正幸
    • Organizer
      2015年度精密工学会春季大会学術講演会
    • Place of Presentation
      東洋大学,東京都
    • Year and Date
      2015-03-17 – 2015-03-19
    • Related Report
      2014 Annual Research Report
  • [Presentation] Inspection system for a straight pipe inner surface by using multiwavelength digital holography2014

    • Author(s)
      T. Koyama and M. Yokota
    • Organizer
      GUMI&AMDE2014
    • Place of Presentation
      桐生市民文化会館,日本
    • Year and Date
      2014-12-05
    • Related Report
      2014 Annual Research Report
  • [Presentation] Analysis of the reconstructed images in phase-shifting digital holography using a plastic optical fiber guide for the hologram transmission2014

    • Author(s)
      M. Yokota, K. Nomura, and M. Konishi
    • Organizer
      GUMI&AMDE2014
    • Place of Presentation
      桐生市民文化会館,日本
    • Year and Date
      2014-12-05
    • Related Report
      2014 Annual Research Report
  • [Presentation] ディジタルホログラフィの工業計測への応用2014

    • Author(s)
      横田正幸
    • Organizer
      2014年度精密工学会秋季大会
    • Place of Presentation
      鳥取大学,鳥取県
    • Year and Date
      2014-09-16
    • Related Report
      2014 Annual Research Report
  • [Presentation] Measurement of the straight pipe inner surface by using multiwavelength color digital holography2014

    • Author(s)
      T. Koyama and M. Yokota
    • Organizer
      2014SICE annual conference
    • Place of Presentation
      北海道大学, 日本
    • Year and Date
      2014-09-09 – 2014-09-12
    • Related Report
      2014 Annual Research Report
  • [Presentation] 多波長ディジタルホログラフィによる円筒内計測システムの開発2014

    • Author(s)
      小山徹平,横田正幸
    • Organizer
      2014年度応用物理・物理系学会中国四国支部合同学術講演会
    • Place of Presentation
      島根大学,島根県
    • Year and Date
      2014-07-26
    • Related Report
      2014 Annual Research Report
  • [Presentation] Digital holographic inspection for a straight pipe inner surface using multiwavelength illuminations2014

    • Author(s)
      M. Yokota (T. Koyama)
    • Organizer
      IPTA2014
    • Place of Presentation
      China National Convention Center, Beijing, China
    • Year and Date
      2014-05-13 – 2014-05-15
    • Related Report
      2014 Annual Research Report
    • Invited
  • [Presentation] Digital holographic inspection for the straight pipe inner surface using multiwavelength from laser diodes2013

    • Author(s)
      M. Yokota, T. Koyama, and T. Kawakami
    • Organizer
      2013 Optical Metrology
    • Place of Presentation
      Germany, Munich
    • Related Report
      2013 Research-status Report
  • [Presentation] Development of a measurement system for pipe inner surface using multi-wavelength digital holography2013

    • Author(s)
      T. Koyama, T. Kawakami and M. Yokota
    • Organizer
      echnical digest of 10th Japan-Finland Joint Symposium on Optics in Engineering (OIE’13)
    • Place of Presentation
      Japan, Tochigi
    • Related Report
      2013 Research-status Report
  • [Presentation] Study of hologram transmission by a high core-number plastic optical fiber (POF) image guide in phase-shifting digital holography2013

    • Author(s)
      K. Nomura and M. Yokota
    • Organizer
      2013 IEEE/SICE International Symposium on System Integration (SII2013)
    • Place of Presentation
      Japan, Kobe
    • Related Report
      2013 Research-status Report
  • [Presentation] GPGPUを用いた逐次記録位相シフトディジタルホログラムの再生計算高速化の検討2013

    • Author(s)
      吉儀拓哉,横田正幸
    • Organizer
      2013年度応用物理物理系学会中国四国支部合同学術講演会
    • Place of Presentation
      香川大学
    • Related Report
      2013 Research-status Report
  • [Presentation] 高画素タイプのPOFイメージガイドによるホログラム伝送と再生像の評価2013

    • Author(s)
      野村佳祐,横田正幸
    • Organizer
      第74回応用物理学会学術講演会
    • Place of Presentation
      同志社大学,京都府
    • Related Report
      2013 Research-status Report
  • [Presentation] 多波長ディジタルホログラフィーによる直管内計測2013

    • Author(s)
      横田正幸,小山徹平
    • Organizer
      第74回応用物理学会学術講演会
    • Place of Presentation
      同志社大学,京都府
    • Related Report
      2013 Research-status Report
  • [Presentation] ディジタルホログラフィによる実時間管内計測のための円錐鏡位置ずれによる表面形状誤差の自動補正法の検討2013

    • Author(s)
      小山徹平,横田正幸
    • Organizer
      第15回IEEE広島支部学生シンポジウム(HISS)
    • Place of Presentation
      鳥取大学,鳥取県
    • Related Report
      2013 Research-status Report
  • [Presentation] 高画素のプラスチックファイバーイメージガイドによるホログラム伝送とシミュレーションを用いた再生像の評価2013

    • Author(s)
      野村佳祐,横田正幸
    • Organizer
      第15回IEEE広島支部学生シンポジウム(HISS)
    • Place of Presentation
      鳥取大学,鳥取県
    • Related Report
      2013 Research-status Report
  • [Presentation] レーザーダイオードを用いた多波長ディジタルホログラフィによる細管内検査2013

    • Author(s)
      小山徹平,横田正幸
    • Organizer
      第22回日本光学会学術講演会(OPJ2013)
    • Place of Presentation
      奈良県
    • Related Report
      2013 Research-status Report
  • [Presentation] Digital holographic inspection for the straight pipe inner surface using multiwavelength from laser diodes2013

    • Author(s)
      横田正幸,小山徹平,河上朋章
    • Organizer
      Optical Metrology 2013
    • Place of Presentation
      ドイツ,ミュンヘン
    • Related Report
      2012 Research-status Report
  • [Presentation] ディジタルホログラフィによるパイプ内検査法における鏡位置ずれ量推定法2012

    • Author(s)
      小山徹平,河上朋章,横田正幸
    • Organizer
      第14回IEEE広島支部学生シンポジウム(HISS)
    • Place of Presentation
      岡山県立大学(岡山市)
    • Related Report
      2012 Research-status Report
  • [Presentation] 多波長ディジタルホログラフィによるパイプ内壁面計測の研究

    • Author(s)
      河上朋章,横田正幸
    • Organizer
      第73回応用物理学会学術講演会
    • Place of Presentation
      愛媛大学(松山市)
    • Related Report
      2012 Research-status Report
  • [Presentation] ディジタルホログラフィによるPOFを用いたホログラム伝送

    • Author(s)
      野村圭祐,横田正幸
    • Organizer
      レーザー学会学術講演会第33回年次大会
    • Place of Presentation
      姫路商工会議所(姫路市)
    • Related Report
      2012 Research-status Report
  • [Remarks] 円筒内形状計測

    • URL

      http://www.ecs.shimane-u.ac.jp/~yokota/shape.html

    • Related Report
      2014 Annual Research Report
  • [Remarks] POFによるホログラム伝送

    • URL

      http://www.ecs.shimane-u.ac.jp/~yokota/pof.html

    • Related Report
      2014 Annual Research Report
  • [Remarks] 2波長位相シフトディジタルホログラフィによる円筒内形状計測

    • URL

      http://www.ecs.shimane-u.ac.jp/~yokota/shape.html

    • Related Report
      2012 Research-status Report

URL: 

Published: 2013-05-31   Modified: 2019-07-29  