• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Development of a collision detection simulator for opimization of 3D irradiation in radiation treatment

Research Project

Project/Area Number 24591853
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeMulti-year Fund
Section一般
Research Field Radiation science
Research InstitutionKyoto College of Medical Science

Principal Investigator

SAWADA AKIRA  京都医療科学大学, 公私立大学の部局等, 教授 (80543446)

Co-Investigator(Renkei-kenkyūsha) MORIYAMA Masamitsu  近畿大学, 大学院総合理工学研究科, 准教授 (00283953)
Project Period (FY) 2012-04-01 – 2015-03-31
Project Status Completed (Fiscal Year 2014)
Budget Amount *help
¥5,200,000 (Direct Cost: ¥4,000,000、Indirect Cost: ¥1,200,000)
Fiscal Year 2014: ¥910,000 (Direct Cost: ¥700,000、Indirect Cost: ¥210,000)
Fiscal Year 2013: ¥1,560,000 (Direct Cost: ¥1,200,000、Indirect Cost: ¥360,000)
Fiscal Year 2012: ¥2,730,000 (Direct Cost: ¥2,100,000、Indirect Cost: ¥630,000)
Keywords干渉検知 / 干渉マップ / 高精度放射線治療 / シミュレータ / 治療計画
Outline of Final Research Achievements

We have developed a patient-specific collision detection simulator among a gantry, a couch, and a patient.This collision detection simulator has a capability to help oncologists/physicists to edit their treatment plans with ease and to make a decision of optimum irradiation direction when collision among them is detected. Furthermore, patient-eye-view function may be useful to give patients to new explanation about their treatments as informed consent.

Report

(4 results)
  • 2014 Annual Research Report   Final Research Report ( PDF )
  • 2013 Research-status Report
  • 2012 Research-status Report
  • Research Products

    (19 results)

All 2014 2013 2012

All Presentation (18 results) (of which Invited: 1 results) Patent(Industrial Property Rights) (1 results)

  • [Presentation] Collision map using a collision detection simulator among treatment appratus for radiotherapy treatment planning2014

    • Author(s)
      A. Sawada, A. Kohnoike, M. Moriyama, Y. Ishihara, T. Shiinoki, Y. Miyabe, Y. Suzuki, T. Mizowaki, M. Kokubo, M. Hiraoka
    • Organizer
      第107回日本医学物理学会学術大会
    • Place of Presentation
      横浜
    • Year and Date
      2014-04-10 – 2014-04-13
    • Related Report
      2014 Annual Research Report
  • [Presentation] Development of hybrid dynamic tumor tracking irradiation using Vero4DRT: A preliminary study2014

    • Author(s)
      M. Sueoka, A. Sawada, Y. Ishihara, M. Yamada, H. Tanabe, Y. Okada, Y. Suzuki, K. Takayama, M. Kokubo, M. Hiraoka
    • Organizer
      第107回日本医学物理学会学術大会
    • Place of Presentation
      横浜
    • Year and Date
      2014-04-10 – 2014-04-13
    • Related Report
      2014 Annual Research Report
  • [Presentation] Impact of respiratory signal exceeding range of correlation model on predictive accuracy in infrared-marker-based dynamic tumor tracking2014

    • Author(s)
      H. Tanabe, M. Sueoka, N. Mukumoto, M. Nakamura, N. Ueki, Y. Matsuo, K. Takayama, A. Sawada, M. Kokubo, M. Hiraoka
    • Organizer
      第107回日本医学物理学会学術大会
    • Place of Presentation
      横浜
    • Year and Date
      2014-04-10 – 2014-04-13
    • Related Report
      2014 Annual Research Report
  • [Presentation] 3D collision map creation using patient-specific collision detection2014

    • Author(s)
      A. Sawada, A. Kohnoike, M. Moriyama, Y. Ishihara, T. Shiinoki, Y. Miyabe, Y. Suzuki, T. Mizowaki, M. Kokubo, M. Hiraoka
    • Organizer
      ESTRO 33
    • Place of Presentation
      Vienna
    • Year and Date
      2014-04-04 – 2014-04-08
    • Related Report
      2014 Annual Research Report
  • [Presentation] Development of hybrid dynamic tumor tracking irradiation using Vero4DRT2014

    • Author(s)
      M. Sueoka, A. Sawada, Y. Ishihara, M. Yamada, H. Tanabe, Y. Okada, Y. Suzuki, K. Takayama, M. Kokubo, M. Hiraoka
    • Organizer
      ESTRO 33
    • Place of Presentation
      Vienna
    • Year and Date
      2014-04-04 – 2014-04-08
    • Related Report
      2014 Annual Research Report
  • [Presentation] Development of 4D Monte Carlo dose calculation system for intensity2014

    • Author(s)
      Y. Ishihara, A. Sawada, A. Nakamura, Y. Miyabe, T. Ono, M. Nakamura, S. Itasaka, T. Mizowaki, M. Kokubo, M. Hiraoka
    • Organizer
      ESTRO 33
    • Place of Presentation
      Vienna
    • Year and Date
      2014-04-04 – 2014-04-08
    • Related Report
      2014 Annual Research Report
  • [Presentation] 光学位置センサを用いた放射線治療装置の衝突検知シミュレータの精度評価2014

    • Author(s)
      渡邊大悟, 澤田晃, 鴻池晃, 末岡正輝, 小久保雅樹, 森山真光
    • Organizer
      電子情報通信学会関西支部 第19回学生会研究発表講演会
    • Place of Presentation
      京都
    • Related Report
      2013 Research-status Report
  • [Presentation] Development of a collision detection simulator among treatment apparatus for radiotherapy treatment planning2013

    • Author(s)
      A. Sawada, A. Kohnoike, M. Moriyama, Y. Ishihara, T. Shiinoki, Y. Miyabe, Y. Suzuki, T. Mizowaki, M. Kokubo, M. Hiraoka
    • Organizer
      第105回日本医学物理学会
    • Place of Presentation
      横浜
    • Related Report
      2013 Research-status Report
  • [Presentation] Development of a patient-specific collision detection simulator among gantry, couch, and patient for Vero4DRT2013

    • Author(s)
      A. Sawada, A. Kohnoike, M. Moriyama, Y. Ishihara, T. Shiinoki, Y. Miyabe, Y. Suzuki, T. Mizowaki, M. Kokubo, M. Hiraoka
    • Organizer
      The 2nd ESTRO forum
    • Place of Presentation
      ジュネーブ
    • Related Report
      2013 Research-status Report
  • [Presentation] Improvement of collision detection simulator for Vero4DRT using software quality metrics2013

    • Author(s)
      A. Kohnoike, M. Moriyama, A. Sawada, Y. Suzuki, M. Kokubo, M. Hiraoka
    • Organizer
      13th Asia-Oceania congress of medical physics
    • Place of Presentation
      シンガポール
    • Related Report
      2013 Research-status Report
  • [Presentation] Development of a patient-specific collision detection simulator among gantry, couch, and patient for Vero4DRT2013

    • Author(s)
      A. Sawada, A. Kohnoike, M. Moriyama, Y. Ishihara, T. Shiinoki, Y. Miyabe, Y. Suzuki, T. Mizowaki, M. Kokubo, M. Hiraoka
    • Organizer
      13th Asia-Oceania congress of medical physics
    • Place of Presentation
      シンガポール
    • Related Report
      2013 Research-status Report
  • [Presentation] 放射線治療装置Vero4DRTシミュレータの衝突回避機能に関する研究2013

    • Author(s)
      鴻池輝、澤田晃、石原佳知、宮部結城、鈴木保恒、小久保雅樹、森山真光
    • Organizer
      2013年電子情報通信学会総合大会
    • Place of Presentation
      岐阜
    • Related Report
      2012 Research-status Report
  • [Presentation] 画像誘導放射線治療の基礎2012

    • Author(s)
      澤田晃
    • Organizer
      第71回日本医学放射線学会
    • Place of Presentation
      横浜
    • Related Report
      2012 Research-status Report
    • Invited
  • [Presentation] Development of a dynamic tumor tracking irradiatio system, Vero4DRT, with a gimbaled x-ray head2012

    • Author(s)
      A. Sawada, Y. Matsuo, Y. Miyabe, M. Nakamura, T. Shiinoki, Y. Ishihara, N. Mukumoto , T. Mizowaki, M. Kokubo, M. Hiraoka
    • Organizer
      The 31st European Society of Therapeutic Radiology and Oncology
    • Place of Presentation
      バルセロナ
    • Related Report
      2012 Research-status Report
  • [Presentation] An Initial Experience of Dynamic Tumor Tracking Irradiation with Real-time Monitoring using Vero4DRT2012

    • Author(s)
      Y. Matsuo, A. Sawada, N. Ueki, Y. Miyabe, M. Nakamura, S. Yano, S. Kaneko, T. Mizowaki, M. Kokubo, M. Hiraoka
    • Organizer
      The 31st European Society of Therapeutic Radiology and Oncology
    • Place of Presentation
      バルセロナ
    • Related Report
      2012 Research-status Report
  • [Presentation] Four-dimensional Monte Carlo dose calculation method for dynamic tumor tracking irradiation with a gimbaled X-ray head2012

    • Author(s)
      Y. Ishihara, A. Sawada, Y. Miyabe, N. Mukumoto, M. Nakamura, N. Ueki, Y. Matsuo, T. Mizowaki, M. Kokubo M. Hiraoka
    • Organizer
      The 54th American Society of Radiation Oncology
    • Place of Presentation
      ボストン
    • Related Report
      2012 Research-status Report
  • [Presentation] Dynamic Tumor Tracking Irradiation with Real-time Monitoring using Vero4DRT (MHI-TM2000)2012

    • Author(s)
      Y. Matsuo, A. Sawada, N. Ueki, et al.
    • Organizer
      The 4th Japan-Korea-China Trilateral Symposium on Raidation Oncology
    • Place of Presentation
      横浜
    • Related Report
      2012 Research-status Report
  • [Presentation] 肺腫瘍動体追尾照射のためのガフクロミックフィルムモデルを用いた簡易的透視被ばく線量測定法の開発2012

    • Author(s)
      椎木健裕、澤田晃、石原佳知、宮部結城、藤本隆広、中井高広、松尾幸憲、溝脇尚志、小久保雅樹、平岡真寛
    • Organizer
      第25回日本放射線腫瘍学会
    • Place of Presentation
      東京
    • Related Report
      2012 Research-status Report
  • [Patent(Industrial Property Rights)] 放射線画像解析装置、放射線治療システム、マーカ部分検出方法およびプログラム2013

    • Inventor(s)
      山田昌弘、澤田晃
    • Industrial Property Rights Holder
      山田昌弘、澤田晃
    • Industrial Property Rights Type
      特許
    • Industrial Property Number
      2012-001599
    • Filing Date
      2013
    • Related Report
      2012 Research-status Report

URL: 

Published: 2013-05-31   Modified: 2019-07-29  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi