Prediction of shock status by Quantified capillary refill time
Project/Area Number |
24592742
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Multi-year Fund |
Section | 一般 |
Research Field |
Emergency medicine
|
Research Institution | Yokohama City University |
Principal Investigator |
MORIMURA Naoto 横浜市立大学, 医学(系)研究科(研究院), 教授 (20239685)
|
Co-Investigator(Kenkyū-buntansha) |
GOTO Takahisa 横浜市立大学, 医学研究科, 教授 (00256075)
SAKAMOTO Tetsuya 帝京大学, 医学部, 教授 (40365979)
|
Research Collaborator |
OHI Yasufumi
MATSUMORI Kyoko
OTSUKA Tsuyoshi
MUGURUMA Takashi
|
Project Period (FY) |
2012-04-01 – 2015-03-31
|
Project Status |
Completed (Fiscal Year 2014)
|
Budget Amount *help |
¥5,460,000 (Direct Cost: ¥4,200,000、Indirect Cost: ¥1,260,000)
Fiscal Year 2014: ¥1,300,000 (Direct Cost: ¥1,000,000、Indirect Cost: ¥300,000)
Fiscal Year 2013: ¥1,170,000 (Direct Cost: ¥900,000、Indirect Cost: ¥270,000)
Fiscal Year 2012: ¥2,990,000 (Direct Cost: ¥2,300,000、Indirect Cost: ¥690,000)
|
Keywords | 毛細血管再充満時間 / ショック / パルスオキシメータ / 乳酸 |
Outline of Final Research Achievements |
In this study, we tried to quantify the capillary refill time (Q-CRT) measured from a change of light intensity in near infrared and red light before and after the compression of finger nail bed based on a principle of pulse oximeter. Mean value of Q-CRT of healthy adult volunteers was 1.6 seconds. Since there was the difference of measured value of Q-CRT between the examiners, we developed the new device for measurement of Q-CRT by the automatic and constant pneumatic compression to finger nail bed. In addition, we focused on the difference of light intensity during compression of finger nail bed between infra-red and red light (ΔAb). TheΔAb more than 0.06 was well correlated to the status with blood lactate level more than 2.0 mmol/l.
|
Report
(4 results)
Research Products
(7 results)
-
-
-
[Presentation] Quantitative capillary refill time (Q-CRT): A novel technique for the measurement of CRT with its excellent diagnostic accuracy of the status of high blood lactate level in critically ill patients.2013
Author(s)
Morimura N, Takahashi K, Doi T, Ohnuki T, Kobayashi N, Sakamoto T, Uchida Y, Takahashi H, Fujita T, Ikeda H
Organizer
The 18th World Congress on Disaster and Emergency Medicine
Place of Presentation
Manchester, United Kingdom
Related Report
-
[Presentation] Quantitative capillary refill time (Q-CRT): A novel technique of the CRT measurement by applying the principle of pulse oximeter.2013
Author(s)
Morimura N, Takahashi K, Doi T, Nakamura K, Yumori A, Kawamura Y, Suzuki N, Ishikawa J, Matsumoto J, Harunari N
Organizer
The 26th European Society of Intensive Care Medicine
Place of Presentation
Paris, France
Related Report
-
-
-