Study on a comprehensive radiation exposure management protocol for measuring patient entrance doses in cardiac interventional procedures and cardiac computed tomography.
Project/Area Number |
24601002
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Multi-year Fund |
Section | 一般 |
Research Field |
医学物理学・放射線技術学
|
Research Institution | Tohoku University |
Principal Investigator |
KATO Mamoru 東北大学, 医学(系)研究科(研究院), 非常勤講師 (10595573)
|
Co-Investigator(Kenkyū-buntansha) |
CHIDA Koichi 東北大学, 災害科学国際研究所, 教授 (20323123)
MORITAKE Takashi 産業医科大学, 付置研究所, 准教授 (50450432)
|
Research Collaborator |
SATO Tadaya 会津中央病院, 循環器病センター, 所長
ABE Yosjihisa , 秋田県立脳血管研究センター, 副センター長
|
Project Period (FY) |
2012-04-01 – 2015-03-31
|
Project Status |
Completed (Fiscal Year 2014)
|
Budget Amount *help |
¥5,590,000 (Direct Cost: ¥4,300,000、Indirect Cost: ¥1,290,000)
Fiscal Year 2014: ¥1,430,000 (Direct Cost: ¥1,100,000、Indirect Cost: ¥330,000)
Fiscal Year 2013: ¥1,690,000 (Direct Cost: ¥1,300,000、Indirect Cost: ¥390,000)
Fiscal Year 2012: ¥2,470,000 (Direct Cost: ¥1,900,000、Indirect Cost: ¥570,000)
|
Keywords | 放射線障害 / インターベンション / 冠動脈CT / 線量測定 / 被曝管理 / 最大皮膚線量 / 蛍光ガラス線量計 / 診断参考レベル / 患者被ばく線量 / 心臓CT時の被ばく線量 / IVR時の被ばく線量 / DAP / AK / CTDI / DLP / 患者被曝線量 / ガラス線量計 / 心臓CTの被曝線量 / 血管撮影時の被曝線量 / 透視時間 / 心臓CTの被ばく線量 / 血管撮影時の被ばく線量 |
Outline of Final Research Achievements |
Interventional cardiology, such as percutaneous coronary intervention (PCI), are increasingly being adopted in the treatments for coronary artery disease. Unfortunately, several cases of skin injury caused by radiation exposure are still being reported in association with PCIs. Furthermore, coronary computed tomography (CT), which is a promising non-invasive technique for the detection of coronary stenosis, is increasingly utilized for the preoperative examination and postoperative assessment of PCI. Compared to other CT examinations, coronary CT examinations deliver a higher dose. In addition, many CT protocols do not provide a method for evaluating the patient entrance skin dose. Thus, high radiation doses may have deterministic effects. Using multiple radiophotoluminescence glass dosimeters with a modified dosimetry gown to measuring the entrance skin doses in PCI and coronary CT, we developed a comprehensive radiation exposure management protocol to prevent radiation skin injuries.
|
Report
(4 results)
Research Products
(25 results)
-
[Journal Article] Study on the Development of a Patient Dosimetry Gown for Interventional Cardiology Procedures2014
Author(s)
加藤 守, 千田 浩一, 盛武 敬, 小口 靖弘, 加賀 勇治, 坂本 肇, 塚本 篤子, 川内 覚, 松本 一真, 松村 光章, 大阪 肇, 土佐 鉄雄
-
Journal Title
Japanese Journal of Radiological Technology
Volume: 70
Issue: 8
Pages: 814-820
DOI
NAID
ISSN
0369-4305, 1881-4883
Related Report
Peer Reviewed / Open Access / Acknowledgement Compliant
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-