Development of time jitter monitor between electron accelerator and synchronized laser by using frequency decoded EO sampling method.
Project/Area Number |
24651097
|
Research Category |
Grant-in-Aid for Challenging Exploratory Research
|
Allocation Type | Multi-year Fund |
Research Field |
Quantum beam science
|
Research Institution | The University of Tokyo |
Principal Investigator |
IWASAKI Atsushi 東京大学, 大学院・理学系研究科, 特任助教 (30447073)
|
Project Period (FY) |
2012
|
Project Status |
Completed (Fiscal Year 2012)
|
Budget Amount *help |
¥2,080,000 (Direct Cost: ¥1,600,000、Indirect Cost: ¥480,000)
Fiscal Year 2012: ¥2,080,000 (Direct Cost: ¥1,600,000、Indirect Cost: ¥480,000)
|
Keywords | 量子ビーム計測手法 / コヒーレント / 自由電子レーザー / EOサンプリング / 極端紫外光 / 原子イオン化 |
Research Abstract |
In order to improve the synchronization between the electron linac and ultra-short pulse laser, jitter timing monitor based on the electro-optic sampling technique was developed and examined. The resulting timing jitter was estimated to be200 fs, and the synchronization was stabilized by introducing feed back of the timing drift to the laser trigger circuit in long time scale.
|