Budget Amount *help |
¥3,120,000 (Direct Cost: ¥2,400,000、Indirect Cost: ¥720,000)
Fiscal Year 2013: ¥1,430,000 (Direct Cost: ¥1,100,000、Indirect Cost: ¥330,000)
Fiscal Year 2012: ¥1,690,000 (Direct Cost: ¥1,300,000、Indirect Cost: ¥390,000)
|
Outline of Final Research Achievements |
As a fundamental tool for developing a new method to solve inverse problem in intensity modulated radiation therapy, we developed an in-house treatment planning system based on a Monte-Carlo algorithm, as well as pencil beam convolution and superposition/convolution dose calculation algorithms. We also developed a in-house software to manipulate and analyze DICOM-RT files and a simple method to determine the X-ray spectrum from the treatment head of a radiation therapy apparatus.
|