Budget Amount *help |
¥4,940,000 (Direct Cost: ¥3,800,000、Indirect Cost: ¥1,140,000)
Fiscal Year 2015: ¥1,300,000 (Direct Cost: ¥1,000,000、Indirect Cost: ¥300,000)
Fiscal Year 2014: ¥1,950,000 (Direct Cost: ¥1,500,000、Indirect Cost: ¥450,000)
Fiscal Year 2013: ¥1,690,000 (Direct Cost: ¥1,300,000、Indirect Cost: ¥390,000)
|
Outline of Final Research Achievements |
This study describes the results of dielectric liquid pool boiling experiments on a polished copper wall with the application of an electric field. Then, micro-structured surfaces were used as the boiling surface. Finally, the combination of the application of electric filed and the micro-structured surface was tested. In addition, the effect of the electric filed and the micro-structured surface on critical heat flux (CHF) were analytically investigated. The maximum CHF with the application of electric field was 4 times greater than that for the pool boiling. The CHF were increased by the micro-structured surface, and showed maximally 40 % higher than the CHF for the polished surface. The combined effects of the electric filed and the micro-structured surface increased the CHF significantly, which was 4.5 times greater than that for the pool boiling. The combined effect on CHF was sufficiently detected by the analysis results.
|