• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Diagnostic accuracy of novel semiconductor camera system for coronary artery disease with low-dose radioisotope

Research Project

Project/Area Number 25461072
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeMulti-year Fund
Section一般
Research Field Cardiovascular medicine
Research InstitutionTokyo Medical University

Principal Investigator

CHIKAMORI Taishiro  東京医科大学, 医学部, 教授 (80197607)

Co-Investigator(Renkei-kenkyūsha) TANAKA Nobuhiro  東京医科大学, 医学部, 准教授 (50297305)
HIDA Satoshi  東京医科大学, 医学部, 講師 (90297317)
TANAKA Hirokazu  東京医科大学, 医学部, 准教授 (20408107)
YAMASHITA Jun  東京医科大学, 医学部, 助教 (40424379)
Project Period (FY) 2013-04-01 – 2016-03-31
Project Status Completed (Fiscal Year 2015)
Budget Amount *help
¥4,290,000 (Direct Cost: ¥3,300,000、Indirect Cost: ¥990,000)
Fiscal Year 2015: ¥780,000 (Direct Cost: ¥600,000、Indirect Cost: ¥180,000)
Fiscal Year 2014: ¥2,080,000 (Direct Cost: ¥1,600,000、Indirect Cost: ¥480,000)
Fiscal Year 2013: ¥1,430,000 (Direct Cost: ¥1,100,000、Indirect Cost: ¥330,000)
Keywords放射線被曝 / 心臓核医学検査 / radioisotope / SPECT / 半導体γカメラ / 冠動脈疾患 / fractional flow reserve
Outline of Final Research Achievements

Although stress single-photon emission computed tomography (SPECT) using a cadmium-zinc-telluride (CZT) camera enables radiation dose reduction, only few studies have evaluated its diagnostic accuracy by applying fractional flow reserve (FFR) measurements. We prospectively evaluated 104 consecutive patients with suspected or known coronary artery disease with a low-dose stress/rest protocol (99mTc radiotracer 185/370 MBq) using CZT SPECT. Within 3 months, coronary angiography was performed with FFR measurements.
To detect individual coronary stenosis, respective sensitivity, specificity, and accuracy were 87%, 73%, and 82% for left anterior descending artery stenosis, 76%, 81%, and 79% for left circumflex artery stenosis, and 87%, 92%, and 90% for right coronary artery stenosis. In conclusion, CZT SPECT demonstrated a good diagnostic yield in detecting a significant coronary stenosis as assessed by FFR even when using a low-dose 99mTc protocol with an effective dose less than 5 mSv.

Report

(4 results)
  • 2015 Annual Research Report   Final Research Report ( PDF )
  • 2014 Research-status Report
  • 2013 Research-status Report
  • Research Products

    (24 results)

All 2016 2015 2014 2013 Other

All Journal Article (7 results) (of which Peer Reviewed: 6 results,  Open Access: 2 results,  Acknowledgement Compliant: 2 results) Presentation (17 results) (of which Int'l Joint Research: 3 results)

  • [Journal Article] Diagnostic Performance of a Cadmium-Zinc-Telluride Single-Photon Emission Computed Tomography System With Low-Dose Technetium-99m as Assessed by Fractional Flow Reserve2016

    • Author(s)
      Taishiro Chikamori, Satoshi Hida, Nobuhiro Tanaka, Yuko Igarashi, Jun Yamashita, Chie Shiba, Naotaka Murata, Kou Hoshino, Yohei Hokama, Akira Yamashina
    • Journal Title

      Circulation Journal

      Volume: 80 Issue: 5 Pages: 1217-1224

    • DOI

      10.1253/circj.CJ-16-0087

    • NAID

      130005147648

    • ISSN
      1346-9843, 1347-4820
    • Related Report
      2015 Annual Research Report
    • Peer Reviewed / Open Access / Acknowledgement Compliant
  • [Journal Article] Disgnostic performance of a semiconductor gamma-camera system as studied by multicenter registry2016

    • Author(s)
      Taishiro Chikamori, Kenji Goto, Satoshi Hida, Masao Miyagawa, Hayato Ishimura, Kenji Uchida, Takaya Fukuyama, Teruhito Mochizuki, Akira Yamashina
    • Journal Title

      Journal of Cardiology

      Volume: 印刷中 Issue: 2 Pages: 449-455

    • DOI

      10.1016/j.jjcc.2016.02.020

    • Related Report
      2015 Annual Research Report
    • Peer Reviewed / Open Access
  • [Journal Article] A novel cadmium-zinc-telluride SPECT system: A challenge for nuclear cardiology in Japan2016

    • Author(s)
      Taishiro Chikamori
    • Journal Title

      Annals of Nuclear Cardiology

      Volume: 印刷中

    • Related Report
      2015 Annual Research Report
    • Peer Reviewed / Acknowledgement Compliant
  • [Journal Article] テルル化亜鉛カドミウム半導体カメラにおける低量投与と通常量投与の心筋画質とカウントの比較2015

    • Author(s)
      肥田敏、近森大志郎、田中宏和、五十嵐裕子、柴千恵、臼井靖博、波多野嗣久、内田健二、高橋政樹、山科章
    • Journal Title

      日本心臓核医学会誌

      Volume: 17 Pages: 6-12

    • NAID

      130008009678

    • Related Report
      2014 Research-status Report
    • Peer Reviewed
  • [Journal Article] 日本における新型半導体γカメラの有効性に関する研究2015

    • Author(s)
      山科章、近森大志郎、石村隼人、内田健二、後藤賢治、肥田敏、福山尚哉、宮川正男、望月輝一
    • Journal Title

      核医学

      Volume: 52 Pages: 21-23

    • Related Report
      2014 Research-status Report
  • [Journal Article] Diagnostic performance of a novel cadmium-zinc-telluride gamma camera system assessed using fractional flow reserve2014

    • Author(s)
      Hirokazu Tanaka, Taishiro Chikamori, Nobuhiro Tanaka, Satoshi Hida, Yuko Igarashi, Jun Yamashita, Masashi Ogawa, Chie Shiba, Yasuhiro Usui, Akira Yamashina
    • Journal Title

      Circulation Journal

      Volume: 78 Pages: 2727-2734

    • NAID

      130004690799

    • Related Report
      2014 Research-status Report
    • Peer Reviewed
  • [Journal Article] Comparison of myocardial perfusion imaging between the new high-speed gamma camera and the standard Anger camera2013

    • Author(s)
      Hirokazu Tanaka, Taishiro Chikamori, Satoshi Hida, Kenji Uchida, Yuko Igarashi, Tsuyoshi Yokoyama, Masaki Takahashi, Chie Shiba, Mana Yoshimura, Koichi Tokuuye, Akira Yamashina
    • Journal Title

      Circulation Journal

      Volume: 77 Pages: 1009-1017

    • NAID

      10031139005

    • Related Report
      2013 Research-status Report
    • Peer Reviewed
  • [Presentation] Diagnostic performance of the cadmium-zinc-telluride SPECT system using low-dose technetium-99m with a short-scan time as assessed by fractional flow reserve2016

    • Author(s)
      Satoshi Hida, Taishiro Chikamori, Jun Yamashita, Kou Hoshino, Naotaka Murata, Yuko Igarashi, Chie Shiba, Tetsushi Saitoh, Kimihiko Hirose, Akira Yamashina
    • Organizer
      Eurepean Society of Cardiology Congress 2016
    • Place of Presentation
      Rome, Italy
    • Year and Date
      2016-08-27
    • Related Report
      2015 Annual Research Report
    • Int'l Joint Research
  • [Presentation] Disgnostic value of lung thallium uptake in detecting extensive coronary artery disease using the cadmium-zinc-telluride camera system2016

    • Author(s)
      Tetsushi Saitoh, Taishiro Chikamori, Satoshi Hida, Yuko Igarashi, Chie Shiba, Kimihiko Hirose, Tsuguhisa Hatano, Akira Yamashina
    • Organizer
      European Society of Cardiology Congress 2016
    • Place of Presentation
      Rome, Italy
    • Year and Date
      2016-08-27
    • Related Report
      2015 Annual Research Report
    • Int'l Joint Research
  • [Presentation] Diagnostic performance of the cadmium-zinc-telluride SPECT system using low-dose technetium-99m radiotopes with short-scan time as assessed by fractional flow reserve2016

    • Author(s)
      Satoshi Hida, Taishiro Chikamori, Jun Yamashita, Naotaka Murata, Kunihiro Sakoda, Kou Hoshino, Yuko Igarashi, Chie Shiba, Tetsushi Saitoh, Kimihiko Hirose, Tsuguhisa Hatano, Akira Yamashina
    • Organizer
      第80回日本循環器学会学術集会
    • Place of Presentation
      仙台
    • Year and Date
      2016-03-20
    • Related Report
      2015 Annual Research Report
  • [Presentation] 負荷心筋SPECTにおける左前下行枝1枝病変の検出能:検出器、核種の影響2015

    • Author(s)
      斎藤哲史、近森大志郎、肥田敏、五十嵐裕子、柴千恵、山科章
    • Organizer
      第55回日本核医学会学術総会
    • Place of Presentation
      東京
    • Year and Date
      2015-11-06
    • Related Report
      2015 Annual Research Report
  • [Presentation] Diagnostic performance of the cadmium-zinc-telliride SPECT system with low-dose technetium-99m as assessed by fractional flow reserve2015

    • Author(s)
      Satoshi Hida, Taishiro Chikamori, Nobuhiro Tanaka, Jun Yamashita, Yuko Igarashi, Chie Shiba, Tetsushi Saitoh, Kimihiko Hirose, Yuka Otaki, Akira Yamashina
    • Organizer
      European Society of Cardiology Congress 2015
    • Place of Presentation
      London
    • Year and Date
      2015-08-29 – 2015-09-02
    • Related Report
      2014 Research-status Report
  • [Presentation] Diagnostic performance of an ultrafast gamma camera system as studied by a multi-center registry2015

    • Author(s)
      Kenji Goto, Taishiro Chikamori, Satoshi Hida, Masao Miyagawa, Hayato Ishimura, Kenji Uchida, Takaya Fukuyama, Teruhito Mochizuki, Akira Yamashina
    • Organizer
      European Society of Cardiology Congress 2015
    • Place of Presentation
      London, UK
    • Year and Date
      2015-08-29
    • Related Report
      2015 Annual Research Report
    • Int'l Joint Research
  • [Presentation] Diagnostic performance of a ultrafast gamma camera system as studied by a multi-center registry2015

    • Author(s)
      Kenji Goto, Taishiro Chikamori, Satoshi Hida, Masao Miyagawa, Hayato Ishimura, Kenji Uchida, Takaya Fukuyama, Teruhito Mochizuki, Akira Yamashina
    • Organizer
      第79回日本循環器学会学術集会
    • Place of Presentation
      大阪
    • Year and Date
      2015-04-26
    • Related Report
      2014 Research-status Report
  • [Presentation] Diagnostic value of quantitative analysis of left ventricular function in the detection of multi-vessel coronary artery disease using low-dose protocol2015

    • Author(s)
      Satoshi Hida, Taishiro Chikamori, Yuko Igarashi, Hirokazu Tanaka, Tetsushi Saitoh, Kimihiko Hirose, Yuka Otaki, Yasuhiro Usui, Akira Yamashina
    • Organizer
      第79回日本循環器学会学術集会
    • Place of Presentation
      大阪
    • Year and Date
      2015-04-26
    • Related Report
      2014 Research-status Report
  • [Presentation] Diagnostic performance of the cadmium-zinc-telliride SPECT system with low-dose technetium-99m as assessed by fractional flow reserve2015

    • Author(s)
      Satoshi Hida, Taishiro Chikamori, Nobuhiro Tanaka, Jun Yamashita, Yuko Igarashi, Chie Shiba, Tetsushi Saitoh, Kimihiko Hirose, Yuka Otaki, Akira Yamashina
    • Organizer
      第79回日本循環器学会学術集会
    • Place of Presentation
      大阪
    • Year and Date
      2015-04-26
    • Related Report
      2014 Research-status Report
  • [Presentation] Diagnostic value of left ventricular function of post-stress and at rest in the detection of multi-vessel coronary artery disease as assessed by low-dose protocol using cadmium-zinc-telluride camera2015

    • Author(s)
      Satoshi Hida, Taishiro Chikamori, Hirokazu Tanaka, Yuko Igarashi, Chie Shiba, Tetsushi Saito, Kimihiko Hirose, Yuka Otaki, Akira Yamashina
    • Organizer
      64th Annual Scientific Session of the American College of Cardiology
    • Place of Presentation
      San Diego
    • Year and Date
      2015-03-15
    • Related Report
      2014 Research-status Report
  • [Presentation] 日本における新型半導体γカメラの有効的使用に関する研究2014

    • Author(s)
      近森大志郎
    • Organizer
      第54回日本核医学会学術総会
    • Place of Presentation
      大阪
    • Year and Date
      2014-11-07
    • Related Report
      2014 Research-status Report
  • [Presentation] Diagnostic accuracy of the cadmium-zinc-telluride SPECT system using low-dose protocol with a short-scan time2014

    • Author(s)
      Satoshi Hida, Taishiro Chikamori, Tanaka Hirokazu, Yuko Igarashi, Shiba Chie, Tetsushi Saitoh, Yasuhiro Usui, Tsuguhisa Hatano, Akira Yamashina
    • Organizer
      European Society of Cardiology Congress 2014
    • Place of Presentation
      Barcelona
    • Year and Date
      2014-09-03
    • Related Report
      2014 Research-status Report
  • [Presentation] 半導体検出器搭載SPECT装置「Discovery NM530c」による画像評価

    • Author(s)
      田中宏和、近森大志郎、肥田敏、柴千恵、五十嵐裕子、波多野嗣久、臼井靖博、山科章
    • Organizer
      第23回日本心臓核医学会総会
    • Place of Presentation
      東京
    • Related Report
      2013 Research-status Report
  • [Presentation] Diagnostic value of left ventricular functional assessment in the detection of multi-vessel coronary artery disease using cadmium-zinc-telluride camera system with a low-dose technetium radioisotope

    • Author(s)
      Satoshi Hida, Taishiro Chikamori, Hirokazu Tanaka, Yuko Igarashi, Chie Shiba, Yasuhiro Usui, Tsuguhisa Hatano, Akira Yamashina
    • Organizer
      European Society of Cardiology Congress 2013
    • Place of Presentation
      Amsterdam
    • Related Report
      2013 Research-status Report
  • [Presentation] Difference of myocardial perfusion pattern between cadmium-zinc-telluride and Anger cameras in patients with coronary artery disease

    • Author(s)
      Hirokazu Tanaka, Taishiro Chikamori, Satoshi Hida, Yuko Igarashi, Chie Shiba, Tsuguhisa Hatano, Yasuhiro Usui, Akira Yamashina
    • Organizer
      The 18th Annual Scientific Session of the American Society of Nuclear Cardiology
    • Place of Presentation
      Chicago
    • Related Report
      2013 Research-status Report
  • [Presentation] 日本における新型半導体γカメラの有効的使用に関する研究

    • Author(s)
      近森大志郎
    • Organizer
      第53回日本核医学会学術総会
    • Place of Presentation
      福岡
    • Related Report
      2013 Research-status Report
  • [Presentation] Diagnostic accuracy of the cadmium-zinc-telluride SPECT system using low-dose protocol with a short-scan time

    • Author(s)
      肥田敏
    • Organizer
      第78回日本循環器学会学術集会
    • Place of Presentation
      東京
    • Related Report
      2013 Research-status Report

URL: 

Published: 2014-07-25   Modified: 2019-07-29  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI