• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Integrated diagnostics for ischemic heart disease by qualitative and quantitative analysis of regional myocardial perfusion with use of semiconductor SPECT

Research Project

Project/Area Number 25461829
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeMulti-year Fund
Section一般
Research Field Radiation science
Research InstitutionEhime University

Principal Investigator

Miyagawa Masao  愛媛大学, 医学部附属病院, 准教授 (90346685)

Co-Investigator(Kenkyū-buntansha) Michizuki Teruhito  愛媛大学, 大学院医学系研究科, 教授 (80145094)
Project Period (FY) 2013-04-01 – 2016-03-31
Project Status Completed (Fiscal Year 2015)
Budget Amount *help
¥3,770,000 (Direct Cost: ¥2,900,000、Indirect Cost: ¥870,000)
Fiscal Year 2015: ¥1,040,000 (Direct Cost: ¥800,000、Indirect Cost: ¥240,000)
Fiscal Year 2014: ¥650,000 (Direct Cost: ¥500,000、Indirect Cost: ¥150,000)
Fiscal Year 2013: ¥2,080,000 (Direct Cost: ¥1,600,000、Indirect Cost: ¥480,000)
Keywords心筋血流予備能 / 半導体SPECT / 心筋血流シンチ / 心筋血流シンチグラフィ / 心筋シンチ / SPECT / 冠動脈疾患 / CZTカメラ
Outline of Final Research Achievements

Reliable evidences have been confirmed that myocardial flow reserve (MFR) is a powerful predictor of cardiac events and mortality. The novel semiconductor SPECT camera provides higher sensitivity and higher temporal and spatial resolution enough to acquire dynamic 3-D data during the first pass of a radiotracer in a similar way as PET. We have explored appropriately designed clinical protocols for the camera which includes prone imaging or dynamic imaging and reported the feasibility of them. Subsequently, we have developed novel software for quantitation of global and regional MFRs using the data from dynamic myocardial perfusion SPECT and obtained two patents approval for it. Finally, we have successfully applied the examination for more than 150 patients with coronary artery diseases and got favorable results using the new software. The radiation exposure of patients could be reduced as low as 3.7 to 7.4 mSv, which is another advantage of this procedure.

Report

(4 results)
  • 2015 Annual Research Report   Final Research Report ( PDF )
  • 2014 Research-status Report
  • 2013 Research-status Report
  • Research Products

    (18 results)

All 2016 2015 2014 2013

All Journal Article (8 results) (of which Peer Reviewed: 7 results,  Open Access: 6 results,  Acknowledgement Compliant: 3 results) Presentation (7 results) (of which Int'l Joint Research: 3 results,  Invited: 3 results) Book (1 results) Patent(Industrial Property Rights) (2 results)

  • [Journal Article] Disgnostic performance of a semiconductor gamma-camera system as studied by multicenter registry2016

    • Author(s)
      Taishiro Chikamori, Kenji Goto, Satoshi Hida, Masao Miyagawa, Hayato Ishimura, Kenji Uchida, Takaya Fukuyama, Teruhito Mochizuki, Akira Yamashina
    • Journal Title

      Journal of Cardiology

      Volume: 印刷中 Issue: 2 Pages: 449-455

    • DOI

      10.1016/j.jjcc.2016.02.020

    • Related Report
      2015 Annual Research Report
    • Peer Reviewed / Open Access
  • [Journal Article] Differentiation of myocardial ischemia and infarction assessed by dynamic computed tomography perfusion imaging and comparison with cardiac magnetic resonance and single-photon emission computed tomography.2016

    • Author(s)
      Tanabe Y, Kido T, Uetani T, Kurata A, Kono T, Ogimoto A, Miyagawa M, Soma T, Murase K, Iwaki H, Mochizuki T.
    • Journal Title

      European Radiology

      Volume: 26

    • Related Report
      2015 Annual Research Report
    • Peer Reviewed / Open Access
  • [Journal Article] Novel cardiac SPECT technology with semiconductor detectors: emerging Trends and Future Perspective2015

    • Author(s)
      Masao Miyagawa, Yoshiko Nishiyama, Rami Tashiro,Hayato Ishimura, Yasuyuki Takahashi, Teruhito Mochizuki.
    • Journal Title

      Annals of Nuclear Cardiology

      Volume: 1 Pages: 18-26

    • Related Report
      2015 Annual Research Report
    • Peer Reviewed / Open Access / Acknowledgement Compliant
  • [Journal Article] Combined supine and prone myocardial perfusion single-photon emission computed tomography with a cadmium zinc telluride camera for detection of coronary artery disease.2014

    • Author(s)
      Nishiyama Y, Miyagawa M, Kawaguchi N, Nakamura M, Kido T, Kurata A, Kido T, Ogimoto A, Higaki J, Mochizuki T.
    • Journal Title

      Circulation Journal

      Volume: 78 Pages: 1169-1175

    • NAID

      130003391083

    • Related Report
      2014 Research-status Report
    • Peer Reviewed / Open Access / Acknowledgement Compliant
  • [Journal Article] Dual radioisotopes simultaneous SPECT of 99mTc-tetrofosmin and 123I-BMIPP using a semiconductor detector.2014

    • Author(s)
      Takahashi Y, Miyagawa M, Nishiyama Y, Kawaguchi N, Ishimura H, Mochizuki T.
    • Journal Title

      Asia Oceania J Nucl Med Biol.

      Volume: 3 Pages: 1-14

    • Related Report
      2014 Research-status Report
    • Peer Reviewed / Open Access / Acknowledgement Compliant
  • [Journal Article] Discovery NM530cの使用経験 核医学専門医の立場から2014

    • Author(s)
      宮川正男、西山香子、川口直人、望月 輝一.
    • Journal Title

      心臓核医学

      Volume: 16 Pages: 14-15

    • Related Report
      2014 Research-status Report
    • Open Access
  • [Journal Article] Combined supine and prone myocardial perfusion2014

    • Author(s)
      Nishiyama Y, Miyagawa M, Kawaguchi N, Nakamura M, Kido T, Kurata A, Kido T, Ogimoto A, Higaki J, Mochizuki T.
    • Journal Title

      Circulation Journal

      Volume: 78 Pages: 1169-1175

    • Related Report
      2013 Research-status Report
    • Peer Reviewed
  • [Journal Article] Performance of a semiconductor SPECT system: comparison with a conventional Anger-type SPECT instrument.2013

    • Author(s)
      Takahashi Y, Miyagawa M, Nishiyama Y, Ishimura H, Mochizuki T.
    • Journal Title

      Annals of Nuclear Medicine

      Volume: 27 Pages: 11-16

    • NAID

      10031168063

    • Related Report
      2013 Research-status Report
    • Peer Reviewed
  • [Presentation] The impact of a novel SPECT camera with semiconductor detectors on clinical nuclear cardiology2015

    • Author(s)
      Masao Miyagawa
    • Organizer
      Nuclear Cardiology Seminar
    • Place of Presentation
      Seoul, Korea
    • Year and Date
      2015-12-11
    • Related Report
      2015 Annual Research Report
    • Int'l Joint Research / Invited
  • [Presentation] Development of a Novel Software for Calculating Myocardial Flow Reserve from Dynamic Kinetic Analysis Using a Cadmium-zinc-telluride (CZT) SPECT.2015

    • Author(s)
      Masao Miyagawa
    • Organizer
      Radiological Society of North America (RSNA) 100th Scientific Assembly and Annual Meeting 2015
    • Place of Presentation
      Chicago, USA
    • Year and Date
      2015-11-29
    • Related Report
      2015 Annual Research Report
    • Int'l Joint Research
  • [Presentation] Estimation of myocardial flow reserve on dynamic technetium-99m SPECT using an ultrafast CZT gamma camera for detection of multivessel coronary artery disease.2015

    • Author(s)
      Masao Miyagawa
    • Organizer
      International Symposium 2015 in Hokkaido; Perspectives on Nuclear Medicine for Molecular Diagnosis and Integrated Therapy.
    • Place of Presentation
      京王プラザホテル、中央区、札幌、北海道
    • Year and Date
      2015-07-31
    • Related Report
      2015 Annual Research Report
    • Int'l Joint Research / Invited
  • [Presentation] Feasibility of Stress-only CZT Myocardial Perfusion SPECT with Combined Spine and Prone Imaging.2014

    • Author(s)
      Nishiyama Y, Miyagawa M, Yokoyama R, Tanabe Y, Matsuda T, Nakamura M, Kido T, Mochizuki T.
    • Organizer
      RSNA 100th Annual Meeting.
    • Place of Presentation
      Chicago, USA
    • Year and Date
      2014-11-29 – 2014-12-05
    • Related Report
      2014 Research-status Report
  • [Presentation] Estimation of myocardial flow reserve using a Cadmium-Zinc-Telluride (CZT) SPECT in patients with mylti-vessel coronary artery disease.2014

    • Author(s)
      Miyagawa M, Nishiyama Y, Mochizuki T.
    • Organizer
      17th Workshop of the Japanese-German Radiological Affiliation.
    • Place of Presentation
      福岡
    • Year and Date
      2014-06-06 – 2014-06-08
    • Related Report
      2014 Research-status Report
  • [Presentation] Estimation of myocardial fow reserve using a Cadmium-Zinc Telluride (CZT) SPECT in patients with multi-vessel coronary artery disease.2013

    • Author(s)
      Miyagawa M, Nishiyama Y, Kawaguchi N, Matsuda T, Yokoyama R, Teraoka S, Mochizuki T.
    • Organizer
      北米核医学会:SNMMI 2013 Annual Meeting
    • Place of Presentation
      Vancouver, Canada
    • Related Report
      2013 Research-status Report
  • [Presentation] Discovery NM530cの使用経験 核医学専門医の立場から2013

    • Author(s)
      宮川正男, 西山香子, 川口直人, 望月輝一.
    • Organizer
      第53回日本核医学会学術総会
    • Place of Presentation
      福岡
    • Related Report
      2013 Research-status Report
    • Invited
  • [Book] Perspectives on Nuclear Medicine for Molecular Diagnosis and Integrated Therapy.2015

    • Author(s)
      Masao Miyagawa, Yoshiko Nishiyama, Hayato Ishimura, Rami Tashiro, Kana Ide, Teruhito Mochizuki.
    • Total Pages
      95
    • Publisher
      Springer Books
    • Related Report
      2015 Annual Research Report
  • [Patent(Industrial Property Rights)] 3次元ダイナミック心筋核医学画像データのパトラック解析(心筋血流定量法)2014

    • Inventor(s)
      国立大学法人愛媛大、日本メジフィジックス株式会社
    • Industrial Property Rights Holder
      国立大学法人愛媛大、日本メジフィジックス株式会社
    • Industrial Property Rights Type
      特許
    • Industrial Property Number
      2013-063178
    • Filing Date
      2014-04-01
    • Related Report
      2014 Research-status Report
  • [Patent(Industrial Property Rights)] 心筋の局所的な放射能取り込み量の指標化技術2014

    • Inventor(s)
      国立大学法人愛媛大、日本メジフィジックス株式会社
    • Industrial Property Rights Holder
      国立大学法人愛媛大、日本メジフィジックス株式会社
    • Industrial Property Rights Type
      特許
    • Industrial Property Number
      2012-191251
    • Filing Date
      2014-04-01
    • Related Report
      2014 Research-status Report

URL: 

Published: 2014-07-25   Modified: 2019-07-29  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI