Development of real-time dose distribution evaluation system that uses scintillation fiber

Research Project

Project/Area Number 25750164
Research Category

Grant-in-Aid for Young Scientists (B)

Allocation TypeMulti-year Fund
Research Field Biomedical engineering/Biomaterial science and engineering
Research InstitutionKyushu University

Principal Investigator

FUJIBUCHI Toshioh  九州大学, 医学(系)研究科(研究院), 講師 (20375843)

Project Period (FY) 2013-04-01 – 2015-03-31
Project Status Completed (Fiscal Year 2014)
Budget Amount *help
¥4,030,000 (Direct Cost: ¥3,100,000、Indirect Cost: ¥930,000)
Fiscal Year 2014: ¥1,040,000 (Direct Cost: ¥800,000、Indirect Cost: ¥240,000)
Fiscal Year 2013: ¥2,990,000 (Direct Cost: ¥2,300,000、Indirect Cost: ¥690,000)
Keywordsシンチレーションファイバ / MPPC / シンチレータ / 光検出器 / 放射線 / 放射線計測 / 線量分布
Outline of Final Research Achievements

Real time monitoring the dose distribution of patient dose is important from the point of the improvement of the quality of the medical institution. In the present study, to acquire the radiation dose distribution in real time, the basic characteristic as the dosimeter was evaluated by combining two or more scintillators and photodetectors. The plastic scintillation fiber used for the evaluation, and the radiation detector connected with MPPC that was the photodetector was used. Conversion into the dose rate and making the programming were tried from the counting rate. The sensitivity has decreased by there are a lot of count drops, and rising of the dose in a high dose field because of in MPPC that connects the plastic scintillation fiber. It was able to be confirmed to be able to convert it into the dose also with the scintillation detector by doing an appropriate correction.

Report

(3 results)
  • 2014 Annual Research Report   Final Research Report ( PDF )
  • 2013 Research-status Report
  • Research Products

    (1 results)

All 2014

All Presentation (1 results)

  • [Presentation] Evaluation of Basic Characteristics for Measurement of CTDI using Plastic Scintillating Fiber Detector2014

    • Author(s)
      K. Terasaki, T. Fujibuchi, T. Toyoda, Y. Yoshida, T. Akasaka, A. Nohtomi, J. Morishita
    • Organizer
      The 9th annual meeting of the Kyushu radiological medical technology
    • Place of Presentation
      北九州
    • Year and Date
      2014-11-01
    • Related Report
      2014 Annual Research Report

URL: 

Published: 2014-07-25   Modified: 2019-07-29  