Design of cross-ventilation in residential houses and its thermal effect.
Project/Area Number |
59350040
|
Research Category |
Grant-in-Aid for Co-operative Research (A)
|
Allocation Type | Single-year Grants |
Research Field |
建築環境・環境工学
|
Research Institution | Kyushu Institute of Design |
Principal Investigator |
ISHII Akio Kyushu Tnstitute of Desigh, 芸術工学部, 助教授 (40087276)
|
Co-Investigator(Kenkyū-buntansha) |
SAKAKIBARA Noriko Oita University, 教育学部, 講師 (90141473)
NISHIDA Masaru Kyushu Sangyo University, 工学部, 助教授 (30069504)
KATAYAMA Tadahisa Kyushu University, 総合理工学研究科, 教授 (80017938)
|
Project Period (FY) |
1984 – 1986
|
Project Status |
Completed (Fiscal Year 1986)
|
Budget Amount *help |
¥10,500,000 (Direct Cost: ¥10,500,000)
Fiscal Year 1986: ¥1,500,000 (Direct Cost: ¥1,500,000)
Fiscal Year 1985: ¥3,000,000 (Direct Cost: ¥3,000,000)
Fiscal Year 1984: ¥6,000,000 (Direct Cost: ¥6,000,000)
|
Keywords | Cross-ventilation / Thermal effect / Arrangement of residential buildings / Plan of dwelling / Wind tunnel experiment / Sea and land breeze / Seaside city / 温熱感覚 |
Research Abstract |
1. Thermal Effect of Cross-ventilation In order to examine the thermal effect of cross-ventilation, were conducted the measurements of climatic environments at the same time in the two dwellings, one with windows opened and another with windows closed, and the vote experiments on thermal sensations using human subjects. There is difference of around 2 in terms of PMV between the two dwellings. Remarkable effect of cross-ventilation is shown especially when outdoor air temperature is 28-30゜C, as about 70% of the cases of the ventilated room remain in the comfort zone. Using regression equations between outdoor and indoor climatic factors obtained from measured data, nomograms were presented for calculating PMV in the cross-ventilated room with parameters of outdoor air temperature and wind speed. 2. Design of Cross-ventilation in Apartment Houses The wind tunnel experiments were conducted for design of cross-ventilation from the viewpoint of the arrangement of apartment buildings and plann
… More
ing of dwelling unit. For arrangement of apartment buildings pressure difference between the front and back sides of buildings, inducing forces of cross-ventilation, were mainly measured with 1/400-scaled building models. Main parameters were building height, volume ratio to lot area, arrangement of models and wind direction. For planning of dwelling unit air flow distribution was mainly measured with 1/5-scaled dwelling models with one or two rooms. 3. Potential of Utilization of Cross-ventilation For examination of potential of utilization of cross-ventilation in the apartments in the urban area, wind environment of 20 cities mainly composed of seaside city was analysed separately in the daytime and the nighttime, using AMeDAS data. In the most of seaside cities it was clearly shown that prevailing wind direction is that from the sea in the day and the reverse at night. This implies that we can use sea breeze for cross-ventilation if the orientation is properly considered in designing buildings. Less
|