A Research on Earthquake Resisting Properties of Steel Beam-to-Column Connections

Research Project

Project/Area Number 59550374
Research Category

Grant-in-Aid for General Scientific Research (C)

Allocation TypeSingle-year Grants
Research Field Building structures/materials
Research InstitutionHIROSHIMA UNIVERSITY

Principal Investigator

MUKUDAI YOSHIRO  FACULTY OF ENGINEERING, HIROSHIMA UNIVERSITY, 工学部, 教授 (40034293)

Co-Investigator(Kenkyū-buntansha) MATSUO AKIRA  FACULTY OF ENGINEERING, HIROSHIMA UNIVERSITY, 工学部, 助教授 (90034412)
Project Period (FY) 1984 – 1986
Project Status Completed (Fiscal Year 1986)
Budget Amount *help
¥1,600,000 (Direct Cost: ¥1,600,000)
Fiscal Year 1986: ¥200,000 (Direct Cost: ¥200,000)
Fiscal Year 1984: ¥1,400,000 (Direct Cost: ¥1,400,000)
Keywordsbeam-to-column connections / weak panel / monotonic loading / cyclic loading / panel moment / FEM analysis / パネル柱降伏比 / 耐震安全性
Research Abstract

In this research beam, column and connection subassemblages whose flange width-to-thickness ratio ranges 8 to 12 and strength ratio ( <alpha> ) of panel to column(or beam) ranges 0.2 to 0.6 were tested to failure under monotonic or cyclic loading to know the earthquake resisting properties of panel-collapse-type structures. Adopted parameters other than those mentioned above are column (or beam) web width-to-thickness ratio (20[50), column axial force (0.0, 0.3Ny), shape of subassemblages (T or X type). Eight specimens subjected to monotonic loading are selected and analysed through Finite Element Method(FEM). The following conclusions are obtained.
1)FEM analysis gives good approximations to experimental results.
2) An increase of panel moment carrying capacity after yielding of connection panels mainly depends upon increase of panel moment carrying capacity due to strain hardening of panel itself and ultimate moment carrying capacity of column flanges, beam flanges and horizontal stiffeners at four corner points of the panel. In addition as the shear forces acting in these flanges and stiffeners near their intersection point range from 0.15 to 0.25 times the yielding shear forces Qfy, an additional increase of panel moment carrying capacity can be expected.
3) More than 80% of total displacement at loading point of subassemblages whose <alpha> <=!<> 0.4 is attributed to deformation of the connection.
4) Connection of Subassemblages of weak panel type( <alpha> <=!<> 0.4) in monotonic loading have enough plastic deformation capacity ( <gamma> / <gamma> y>40). In comparison to it plastic deformation capacity of connections of those subassemblages( <alpha> <=!<> 0.4) belonged to FB rank in cyclic loading is small.(15[35 <gamma> y)

Report

(1 results)
  • 1986 Final Research Report Summary
  • Research Products

    (2 results)

All Other

All Publications (2 results)

  • [Publications] 椋代二朗: 日本建築学会構造系論文報告集. 375. (1987)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1986 Final Research Report Summary
  • [Publications] Yoshiro Mukudai: "A Study on Load Carrying Capacity and Plastic Deformation Capacity of Beam-to-Column Connections Composed of H-Shaped Members Made of Comparatively Thin Plates" Journal of Structural and Construction Engineering (Transactions of the Architectural Institute of Japan). 375. (1987)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1986 Final Research Report Summary