High resolution apparatus for the measurement of brain microcirculation(blood, cerebrospinal fluid flow) by statistical processing of laser signal

Research Project

Project/Area Number 59870048
Research Category

Grant-in-Aid for Developmental Scientific Research

Allocation TypeSingle-year Grants
Research Field Cerebral neurosurgery
Research InstitutionNagoya University

Principal Investigator

KAGEYAMA NAOKI  Nagoya University School of Medicine, 医学部, 教授 (90022813)

Co-Investigator(Kenkyū-buntansha) MIYAZAKI YASUMITU  Toyohasi University of Technology, 教授 (00023169)
KUCHIWAKI HIROJI  Nagoya University School of Medicine, 医学部, 講師 (60135340)
Project Period (FY) 1984 – 1986
Project Status Completed (Fiscal Year 1986)
Budget Amount *help
¥27,200,000 (Direct Cost: ¥27,200,000)
Fiscal Year 1986: ¥1,000,000 (Direct Cost: ¥1,000,000)
Fiscal Year 1985: ¥1,900,000 (Direct Cost: ¥1,900,000)
Fiscal Year 1984: ¥24,300,000 (Direct Cost: ¥24,300,000)
KeywordsBlood / Cerebrospinal fluid / Laser doppler shift / Safty limit / LDV / レーザードップラー / エネルギー密度 / 血管壁 / 病理
Research Abstract

The aim of this study is noninvasively to measure blood or cerebrospinal fluid(CSF) flow through a wall of a small vessel with a diameter of 1-2 mm using laser doppler method(LDV).
Optical density of the laser beam(He-Ne, 632.8 nm, 27 mW) in blood or through the blood vessel wall (200 u) was enough for detecting laser doppler shift(dF) at the outside of the vessel. Flow velocity of CSF was evaluated through a semitranslucent tube of the ventriculo-peritoneal shunt. An experimental simulation of flow velocity was equipped by Harvard pump.
The most sensitive optical pathway was fringe mode for detecting dF. Simultaneous monitorings of dF were performed with an oscilloscope, a spectrum analyser and Fast Fourier Transformation(FFT). An optical fiber was used for receiving dF by a forward scattering system. Following points were important; 1) use of low cut filter(less than 1 kHz), 2) reliable cut off dF was able to obtain with averaging results of FFT by increasing of sampling number.
By these method linear relationships between dF and velocity of blood and CSF. Dangerous effects in the use of LDV to the wall of the blood vessels were histopathologically evaluated. Irradiations within 60 min as well as power of less than 13.5 mW of He-Ne laser beam (size 200 u) were found a safty limit in the examinations of LDV.
In conclusion, our study and apparatus of LDV are usefull for the noninvasive evaluations of the flow state in small vessels of the clinical materials.

Report

(2 results)
  • 1986 Final Research Report Summary
  • 1985 Annual Research Report
  • Research Products

    (9 results)

All Other

All Publications (9 results)

  • [Publications] 景山直樹: 信学技報. 84. 13-18 (1984)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1986 Final Research Report Summary
  • [Publications] 景山直樹: 日本臨床. 43. 299-303 (1985)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1986 Final Research Report Summary
  • [Publications] 景山直樹: 日本レーザー医学会誌. 6. 167-170 (1986)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1986 Final Research Report Summary
  • [Publications] 景山直樹: 日本レーザー医学会誌. 7. 13-22 (1986)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1986 Final Research Report Summary
  • [Publications] Kageyama N: "A study of noninvasive measurement of blood flow using laser doppler method." Shingakugihou. 84. 13-18 (1984)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1986 Final Research Report Summary
  • [Publications] Kageyama N: "A measurement of blood flow using laser doppler method." Nihonrinshou. 43. 299-303 (1985)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1986 Final Research Report Summary
  • [Publications] Kageyama N: "Histological evaluation of rat carotid artery wall after low-power laser irradiation" Nihon Rezah Igakukkai Shi. 6. 167-170 (1986)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1986 Final Research Report Summary
  • [Publications] Kageyama N: "Histological evaluation of rat carotid artery wall after low-power He-Ne laser irradiation" Nihon Rezah Igakukkan Shi. 7. 13-22 (1986)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1986 Final Research Report Summary
  • [Publications] 日本レーザー医学会誌. 7. (1986)

    • Related Report
      1985 Annual Research Report

URL: 

Published: 1987-03-31   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI