Automated Direct Assay System for The Measurement of Sex Steroid Hormones in Serum Using High Performance Liquid Chromatog

Research Project

Project/Area Number 59870054
Research Category

Grant-in-Aid for Developmental Scientific Research (B).

Allocation TypeSingle-year Grants
Research Field Obstetrics and gynecology
Research InstitutionOkayama University

Principal Investigator

SEKIBA Kaoru  Okayama University, Medical School, Professor, 医学部, 教授 (90033042)

Co-Investigator(Kenkyū-buntansha) SHIMIZU Kenji  Okayama University, Medical School Hospital, Resident Doctor, 医学部附属病院, 医員
URABE Kiyoshi  Okayama University, Medical School Hospital, Assistant Prof., 医学部附属病院, 助手 (70127546)
YASHIDA Nobutaka  Okayama University, Medical School Hospital, Assistant Prof., 医学部附属病院, 助手 (80127597)
HAYASHI Nobuyoshi  Okayama University, Medical School Hospital, Assistant Prof., 医学部附属病院, 助手 (10164948)
Project Period (FY) 1984 – 1986
Project Status Completed (Fiscal Year 1990)
Budget Amount *help
¥12,000,000 (Direct Cost: ¥12,000,000)
Fiscal Year 1986: ¥1,400,000 (Direct Cost: ¥1,400,000)
Fiscal Year 1985: ¥2,900,000 (Direct Cost: ¥2,900,000)
Fiscal Year 1984: ¥7,700,000 (Direct Cost: ¥7,700,000)
KeywordsHigh Performance Liquid Chromatography / Automated Analyzing System / Sex Sterois Hormone / Estradiol / Progesterone / Serum Concentration / Electrochemical Detection / Ultraviolet Spectrophotometric Detection / 高速液体クロマトグラフィー / 自動化装置 / ダイレクトアッセイ法
Research Abstract

An automated direct assay system using high performance liquid chromatography with electrochemical detection and ultraviolet spectrophotometric detection was developed for the simultanltaneous measurement of estradiol, estrone, progesterone, 17alpha-hydroxyprogesterone, 20alpha-hydroxyprogesterone, testosterone and androstenedione in biological fluids. It takes 30 min to measure estrogens, and 80 min to measure whole steroid hormones. The recovery rates of steroid hormones were 77-84%, and the intra-assay coefficients of variation of the peak height were 1.7-3.1%. The relationship between the dose of each steroid hormone and the peak height showed good linearities. A comparison between the values measured by this method and by radioimmunoassay revealed good correlation for estradiol (r=0.938, p<0.001) and progesterone (r=0.903, p<0.001). Estradiol and estrone could be analysed above the level of 250 pg/ml, andprogesterone, 17alpha-hydroxyprogesterone, 20alpha-hydroxyprogesterone, testosterone and androstenedione could be analyzed above the level of 5.0-7.5 ng/ml. The method was applied to the clinical appraisal of placental function and maturation of ovarian follicles.

Report

(3 results)
  • 1990 Final Research Report Summary
  • 1986 Annual Research Report
  • 1985 Annual Research Report
  • Research Products

    (13 results)

All Other

All Publications (13 results)

  • [Publications] 林 伸旨: "Direct assay system for the simultaneous measurement of sex steroid hormones in maternal serum" International HPLc Simposium Abstract. 131-134 (1985)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] 林 伸旨: "高速液体クロマトグラフィ-による性ステロイドホルモン全自動迅速同時測定法" 病態生理. 5. 374-379 (1986)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] 鈴木 康之: "Automated direct assay for the meaeurement of sex steroid hormones in serum using high performance liquid chromatography" Jouranl of Chromatography. 426. 33-40 (1988)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] HAYASHI NOBUYOSHI: "Direct Assay System for the Simultaneous Measurement of Sex Steroid Hormones in Maternal Serum" International HPLC Simposium Abstract. 131-134 (1985)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] HAYASHI NOBUYOSHI: "Automatic Direct Assay System for Rapid and Simultaneous Determination of Sex Steroid Hormones by High Performance Liquid Chromatography" Journal of Medicine Philosophica. 5. 374-379 (1986)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] SUZUKI YASUYUKI: "Automated Direct Sssay System for the Measurement of Sex Steroid Hormones in Serum Using High Performance Liquid Chromatography" Journal of Chromatography. 426. 33-40 (1988)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] 野間純: 第12回世界不妊学会抄録号. 抄録号. 637 (1986)

    • Related Report
      1986 Annual Research Report
  • [Publications] 野間純: 日本不妊学会誌. 31. 725 (1986)

    • Related Report
      1986 Annual Research Report
  • [Publications] 林伸旨: 病態生理. 5. 374-379 (1986)

    • Related Report
      1986 Annual Research Report
  • [Publications] 鈴木康之: 日本産科婦人科学会誌. 抄録号. 83 (1987)

    • Related Report
      1986 Annual Research Report
  • [Publications] 名越一介: 産婦人科の世界. 4月号. (1987)

    • Related Report
      1986 Annual Research Report
  • [Publications] 第11回世界産婦人科学会・抄録号. 237. (1985)

    • Related Report
      1985 Annual Research Report
  • [Publications] 第30回日本不妊学会・日不妊誌. 30-4. (1985)

    • Related Report
      1985 Annual Research Report

URL: 