Study on Indoor Thermal Environment of Traditional Vernacular Houses and Modern Passive Cooling Houses in Seasonally Hot and Humid Areas

Research Project

Project/Area Number 62460172
Research Category

Grant-in-Aid for General Scientific Research (B)

Allocation TypeSingle-year Grants
Research Field 建築環境・環境工学
Research InstitutionKyushu University

Principal Investigator

URANO Yoshimi  Faculty of Engineering, Kyushu University, 工学部, 教授 (90037698)

Co-Investigator(Kenkyū-buntansha) RYU Yuji  Faculty of Engineering, Kyushu University, 工学部, 助手 (20191695)
WATANABE Toshiyuki  Faculty of Engineering, Kyushu University, 工学部, 助教授 (60038106)
Project Period (FY) 1987 – 1988
Project Status Completed (Fiscal Year 1988)
Budget Amount *help
¥4,300,000 (Direct Cost: ¥4,300,000)
Fiscal Year 1988: ¥1,200,000 (Direct Cost: ¥1,200,000)
Fiscal Year 1987: ¥3,100,000 (Direct Cost: ¥3,100,000)
KeywordsSeasonally Hot-Humid Area / Traditional Vernacular House / Passive Cooling House / Energy Saving House / Heat Insulated and Air Tightened House Attached an Underground Room / Indoor Thermal Environment / Vernacular Housing Vocabulary / 実測調査 / 現代住宅 / 付設地下室 / クールチューブ / 在室スケジュール / 断熱気密化 / 室内熱環境調査 / 省エネルギー実験住宅
Research Abstract

The point of applying traditional passive cooling method to modern houses in seasonally hot and humid area is shown through the comarison of indoor thermal environments between traditional vernarcular houses and modern houses referring the difference of materials, structures, designs, and details. The results of this research are as follows:
1. The words relaiting to passive cooling methods were selected from vocablaries of tradi-tional vernacular houses in Japan and classified as to the distinction of location in the houses or the region in Japan.
2. The questionnaire to survey the attitude of designers to passive cooling was conducted gathering the examples of passive design. The survey showed the necessity of exact estimation of passive cooling effect.
3. Several kinds of traditional passive cooling methods vanished from modern houses were confirmed their cooling effects in ten traditional vernacular houses in Kyushu and Okinawa Islands.
4. A modern passive cooling houses in Naha was scrutinized its cooling effects as to the followings; natural ventilation, heat exhaustion, double enveloped roof, vegetation, and water sprinkled roof.
5. An experimental house, completely electrified, in Fukuoka was measured to examine the cooling and energy saving effects of the following items; air-conditioning systems including floor-heating/-cooling, earth contact floors, and outside heat insulation of its basement.
6. A test house, well heat insulated and air tightened, in Tokuyama was measured to examine the effects as to the following items; pair-glazed windows, plastic window sashes, an attached underground room, cooling tubes, and a central heat-pump system for air-contioning.

Report

(3 results)
  • 1988 Annual Research Report   Final Research Report Summary
  • 1987 Annual Research Report
  • Research Products

    (23 results)

All Other

All Publications (23 results)

  • [Publications] 鈴木哲行 他: 日本建築学会九州支部研究報告. 第30号・2. 129-132 (1988)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] 堀口かおり 他: 日本建築学会九州支部研究報告. 第30号・2. 133-136 (1988)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] 藪田尚子 他: 日本建築学会九州支部研究報告. 第30号・2. 137-144 (1988)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] 小川順一 他: 日本建築学会九州支部研究報告. 第30号・2. 157-160 (1988)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] 的野孝一 他: 日本建築学会九州支部研究報告. 第31号・2. 141-152 (1988)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] 堀口かおり 他: 日本建築学会九州支部研究報告. 第31号・2. 157-164 (1988)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] K. Horiguchi, et al.: "A Study on Thermal Environment of Traditional Vernacular Houses in Southern Kyushu" Research Reports of Kyushu Chapter of AIJ. No. 30-2. 133-136 (1988)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] N. Yabuta, et al.: "Field Surveys on Thermal Environment of a Passive Cooling House in Okinawa Part 1 & Part 2" Research Reports of Kyushu Chapter of AIJ. No. 30-2. 137-144 (1988)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] J. Ogawa, et al.: "Study on Thermal Performance of an Energy Saving Test House Part 7 Evaluation of Indoor Thermal Environment and Energy Consumption" Research Reports of Kyushu Chapter of AIJ. No. 30-2. 157-160 (1988)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] K. Matono, et al.: "Passive Cooling Effect of the Heat Insulated and Air Tightened House Attached an Underground Room in Hot and Humid Area Part 1 Outline of the Test House and Its Indoor Thermal Environment Part 2 Effect of Underground Room and Cooling Tube Systems Part 3 Numerical Simulations on Thermal Performance of Cooling Tubes" Research Reports of Kyushu Chapter of AIJ. No. 31-2. 141-152 (1989)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] K. Horiguchi, et al.: "Passive Cooling Devices of Japanese Traditional Vernacular Houses Part 1 & Part 2" Research Reports of Kyushu Chapter of AIJ. No. 31-2. 157-164 (1989)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] 小川順一 他: 日本太陽エネルギー学会 日本風力エネルギー協会 合同研究発表会講演論文集. 65-66 (1988)

    • Related Report
      1988 Annual Research Report
  • [Publications] 財津秀隆 他: 日本建築学会九州支部研究報告. 31・2. 141-144 (1989)

    • Related Report
      1988 Annual Research Report
  • [Publications] 的野孝一 他: 日本建築学会九州支部研究報告. 31・2. 145-148 (1989)

    • Related Report
      1988 Annual Research Report
  • [Publications] 小川順一 他: 日本建築学会九州支部研究報告. 31・2. 149-152 (1989)

    • Related Report
      1988 Annual Research Report
  • [Publications] 堀口かおり 他: 日本建築学会九州支部研究報告. 31・2. 157-164 (1989)

    • Related Report
      1988 Annual Research Report
  • [Publications] 佐々木寛 他: 日本建築学会九州支部研究報告. 31・2. 197-200 (1989)

    • Related Report
      1988 Annual Research Report
  • [Publications] 浦野良美ほか: 日本建築学会建築環境工学学術研究発表会資料. 3. 1-9 (1987)

    • Related Report
      1987 Annual Research Report
  • [Publications] 鈴木哲行ほか: 日本建築学会九州支部研究報告. 30-2. 129-132 (1988)

    • Related Report
      1987 Annual Research Report
  • [Publications] 堀口かおりほか: 日本建築学会九州支部研究報告. 30-2. 133-136 (1988)

    • Related Report
      1987 Annual Research Report
  • [Publications] 佐々木寛ほか: 日本建築学会九州支部研究報告. 30-2. 137-140 (1988)

    • Related Report
      1987 Annual Research Report
  • [Publications] 藪田尚子ほか: 日本建築学会九州支部研究報告. 30-2. 141-144 (1988)

    • Related Report
      1987 Annual Research Report
  • [Publications] 小川順一ほか: 日本建築学会九州支部研究報告. 30-2. 157-160 (1988)

    • Related Report