A Study of Body Temperature Measurement Using the Zero-Heat-Flow Technique

Research Project

Project/Area Number 62550300
Research Category

Grant-in-Aid for General Scientific Research (C)

Allocation TypeSingle-year Grants
Research Field 計測・制御工学
Research InstitutionInstitute for Medical and Dental Engineering

Principal Investigator

TOGAWA Tatsuo  Inst. for Med. & Dent. Eng.. Tokyo Med. & Dent. Univ., 医用器材研究所, 教授 (40013859)

Co-Investigator(Kenkyū-buntansha) TOYOSHIMA Takeshi  Same as above, 医用器材研究所, 助手 (40014146)
TAMURA Toshiyo  Same as above, 医用器材研究所, 助手 (10142259)
TSUJI Takayuki  Same as above, 医用器材研究所, 助教授 (00075764)
根本 鉄  東京医科歯科大学, 医用器材研究所, 教務職員 (90126243)
Project Period (FY) 1987 – 1988
Project Status Completed (Fiscal Year 1988)
Budget Amount *help
¥1,800,000 (Direct Cost: ¥1,800,000)
Fiscal Year 1988: ¥400,000 (Direct Cost: ¥400,000)
Fiscal Year 1987: ¥1,400,000 (Direct Cost: ¥1,400,000)
KeywordsBody temperature / Deep body thermometer / Sublingual temperature / Zero-heat-flow thchnique / 体温モニター / 深部温度 / 執流補償法 / ガリウム温度スタンダード
Research Abstract

The deep body thermometer is an instrument for body temperature monitoring in which zero-heat-flow technique is employed. It was invented by Fox in 1971. improved by one of the investigator of this project (T.T.). and now spreading for post operative patient monitoring and many other applications. However. its ultimate accuracy has not been well studied. The project was planned to investigate the accuracy of the deep body thermometer. and also to provide a modification of the probe design. which is critical to the accuracy.
The probe of the deep body thermometer was modified so that a slight positive feedback control was introduced to compensate the error due to a heat flow from the deep tissue to the ambient air detouring the probe. The performance of the probe was examined by 1) numerical analysis. 2) simulator experiment. and 3) measurements in volunteer subjects.
As the results. it was shown by the numerical analysis and the simulator experiment that the modification in the probe design significantly reduces the measurement error. The subject study showed that the averaged differences between measured body temperatures by the modified probe and a sublingual thermistor probe remained within 0.1゜C in a room temperature of 20゜C and 25゜C.
From these results. it was confirmed that the modification in the probe design could realize accuracy which satisfies most demands of clinical body temperature measurements.

Report

(3 results)
  • 1988 Annual Research Report   Final Research Report Summary
  • 1987 Annual Research Report
  • Research Products

    (15 results)

All Other

All Publications (15 results)

  • [Publications] 戸川達男: 小児看護. 10. 1163-1167 (1987)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] Tsuji.T.: Medical Progress through Technology. 12. 25-38 (1987)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] 戸川達男: BME. 2. 156-160 (1988)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] Nemoto,T.; Togawa,T.: Med.&Biol.Eng.& Comput.26. 456-459 (1988)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] Togawa,T.: "System and control Encyclopeadia,Singh," Pergamon Press, 4851-4856 (1987)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] Togawa,T.: "Encyclopedia of Medical Devices and Instrumentations." John Wiley & Sons, 2765-2770 (1988)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] Togawa, T.: "Clinical thermometers" Jap. J. Child Nurs.10. 1163-1167 (1987)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] Tsuji, T.: "Patient monitoring during and after open heart surgery by improved deep body thermometer" Medical Progress through Technology. 12. 25-38 (1987)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] Togawa, T.: "Progress and present status of clinical thermometry" Bio-Med. Eng.2. 156-160 (1988)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] Nemoto, T.; Togawa, T.: "Improved probe for a deep body thermometer" Med. & Biol. Eng. & Comput.26. 456-459 (1988)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] Togawa, T.: Temperature measurement. Physiological System and Control Encyclopeadia, Singh, M.G. ed.Pergamon Press, 4851-4856 (1987)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] Togawa, T.: Thermometry. Diode Encyclopeadia of Medical Devices and Instumentations, Webster, J.G. ed.John Wiley & Sons, 2765-2770 (1988)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1988 Final Research Report Summary
  • [Publications] 戸川達男: BME. 2. 156-160 (1988)

    • Related Report
      1988 Annual Research Report
  • [Publications] Nemoto.T.;Togawa.T.: Med.&Biol.Eng.& Comput.26. 456-459 (1988)

    • Related Report
      1988 Annual Research Report
  • [Publications] Togawa.T.: "Encyclopedia of Medical Devices and Instrumentations.Webster.J.G.ed." John Wiley & Sons, 2765-2770 (1988)

    • Related Report
      1988 Annual Research Report