• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

RESEARCH FOR THE APPLICATION OF INTRALUMINAL SUTURELESS PROSTHESIS WITH SHAPE MEMORY ALLOY IN THE TREATMENT OF DISSECTING ANEURYSM

Research Project

Project/Area Number 63480317
Research Category

Grant-in-Aid for General Scientific Research (B)

Allocation TypeSingle-year Grants
Research Field Thoracic surgery
Research InstitutionTOHOKU UNIVERSITY

Principal Investigator

SUZUKI Yasuyuki  TOHOKU UNIV. SCHOOL OF MEDICINE ASSOCIATE PROF., 医学部, 助教授 (50004924)

Co-Investigator(Kenkyū-buntansha) ITO Yasuhiro  TOHOKU UNIV. SCHOOL OF MEDICINE INSTRUCTOR, 医学部, 助手 (40213095)
YAMAKI Shigeo  TOHOKU UNIV. SCHOOL OF MEDICINE ASSISTANT PROF., 医学部付属病院, 講師 (30133953)
ZUGUCHI Masayuki  TOHOKU UNIV. SCHOOL OF MEDICINE INSTRUCTOR, 医学部付属病院, 助手 (20172075)
NITTA Sin-ichi  TOHOKU UNIV. THE RESEARCH INSTITUTE FOR CHEST DISEASE AND CANCER ASSOCIATE PROF., 抗酸菌病研究所, 助教授 (90101138)
Project Period (FY) 1988 – 1989
Project Status Completed (Fiscal Year 1989)
Budget Amount *help
¥4,200,000 (Direct Cost: ¥4,200,000)
Fiscal Year 1989: ¥300,000 (Direct Cost: ¥300,000)
Fiscal Year 1988: ¥3,900,000 (Direct Cost: ¥3,900,000)
KeywordsDISSECTING ANEURYSM / INTRALUMINAL SUTURELESS PROSTHESIS / SHAPE MEMORY ALLOY
Research Abstract

The purpose of this study is to develop intraluninal sutureless prosthesis with shape memory alloy ring which could be inserted through distal artery( ie.femoral or external iliac a ) by means of conventional catheterization method.
Although several types of prosthesis were tried, it was very difficult to deform them so small enough to be inserted through distal arteries. So we developed another type of prosthesis which made of shape memory alloy plate,namely, thin long plate of shape memory alloy is rolled spirally,and formed tubular shape. We made two different size of this type , one was 10mm in diameter,40mm in length and another 20mm in diameter 40mm in length. Small one was deformed very easily to 3mm in diameter in the bath of cold water and big one was to 5mm in diameter in the same manner. And then, we successfully resumed then in the mock circulation system by warming themselves electrically.
Further study is needed, but this easy deformity could make it possible to insert this type of prosthesis through distal arteries.

Report

(3 results)
  • 1989 Annual Research Report   Final Research Report Summary
  • 1988 Annual Research Report

URL: 

Published: 1988-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi