Project/Area Number |
63480319
|
Research Category |
Grant-in-Aid for General Scientific Research (B)
|
Allocation Type | Single-year Grants |
Research Field |
Thoracic surgery
|
Research Institution | University of Nagoya School of Medicine (1988, 1990) Kobe University (1989) |
Principal Investigator |
ITO Takahiro University of Nagoya, School of Medicine, Dept. of Surgery, Branch Hospital, Professor, 医学部, 教授 (10022899)
清水 富男 (1989) 神戸大学, 医学部附属病院, 助手 (90196527)
|
Co-Investigator(Kenkyū-buntansha) |
TAKAGI Hiroyuki Cyuhkyoh Hospital, Dept. of Research, Head, 研究部, 部長
IIO Kenji University of Nagoya, School of Medicine, Dept. of Surgery, Branch Hospital, Ass, 医学部, 助手 (10184334)
臼井 康雄 神戸大学, 医学部附属病院, 助手 (20203523)
松原 司 神戸大学, 医学部, 助手 (80192342)
|
Project Period (FY) |
1988 – 1990
|
Project Status |
Completed (Fiscal Year 1990)
|
Budget Amount *help |
¥6,400,000 (Direct Cost: ¥6,400,000)
Fiscal Year 1990: ¥400,000 (Direct Cost: ¥400,000)
Fiscal Year 1989: ¥1,100,000 (Direct Cost: ¥1,100,000)
Fiscal Year 1988: ¥4,900,000 (Direct Cost: ¥4,900,000)
|
Keywords | ECMO / VA-bypass / membrane oxygenation / neonatal respiratory failure / VAーbypass / カテュラミン / 新生児急性呼吸不全 / 大腿骨頭壊死 / 脂質代謝異常 / ステロイド / アルコ-ル / 体外循環 / 血液ポンプ / 自動制御 / カテコ-ルアミン |
Research Abstract |
Conventional ECMO circuits with a roller pump are not always free from serious mechanical problems like venous collapse, air embolism, burst of the arterial line. A new, safer, and more practical ECMO circuit with an automatic blood pump was developed. Our neonatal ECMO circuit primed 65 ml consisted of blood pumps with 4 mm ball valves and a membrane oxygenator of 0.5 sq.m. Our pediatric ECMO circuit primed 120 ml with 6 mm valves and a membrane oxygenator of 0.8 sq.m. The pump could change output automatically in response to its filling and thereby did not produce excessive negative pressure. Our ECMO circuits had been extensively tested on a mock circulation system and used on dogs. No mechanical problem had been encountered in continuous driving on the mock circulation system for 21 days. Bypass flow changed automatically in response to venous return, but remained constant against changes in arterial pressure. Effect of ECMO using our automatic blood pumps on hemodynamics was studied on 50 dogs. During VA-ECMO mean pulmonary arterial pressure and right ventricular pressure decreased. When the flow increased more than 50 ml/kg/min, the aortic systolic pressure tended to decrease more significantly than the systolic left ventricular pressure. The endodiastric pressure in both right and left ventricles elevated at high bypass flow. These findings indicated that VA-ECMO of high frow caused ventricular strain. In conclusion, our automatic ECMO circuit is a safe and useful device treating small infants with acute respiratory failure but VA-ECMO flow should be kept as little as possible because of possible ill effects on the heart.
|