Development of Apatite Ceramic Technology-Aided Functional Neuromuscular Stimulation System

Research Project

Project/Area Number 63870057
Research Category

Grant-in-Aid for Developmental Scientific Research (B).

Allocation TypeSingle-year Grants
Research Field Orthopaedic surgery
Research InstitutionTokyo Medical and Dental University (1989-1990)
Tokyo Gakugei University (1988)

Principal Investigator

AOKI Hideki  Tokyo Medical and Dental University, Institute for Medical and Dental Engineering, Professor, 医用器材研究所, 教授 (80014166)

Co-Investigator(Kenkyū-buntansha) SHIN Yoshiharu  Advance Inc., Head Laboratory, Director, 本社研究室, 主席研究員
AKAO Masaru  Tokyo Medical and Dental University, Institute for Medical and Dental Engineerin, 医用器材研究所, 助教授 (50143607)
Project Period (FY) 1988 – 1990
Project Status Completed (Fiscal Year 1990)
Budget Amount *help
¥5,700,000 (Direct Cost: ¥5,700,000)
Fiscal Year 1990: ¥900,000 (Direct Cost: ¥900,000)
Fiscal Year 1989: ¥1,800,000 (Direct Cost: ¥1,800,000)
Fiscal Year 1988: ¥3,000,000 (Direct Cost: ¥3,000,000)
KeywordsHydroxyapatite percutaneous devices / Composite electrodes / Hydroxyapatite-carbon composite materials / Implantable skin interface / Percutaneous electrical connector / Functional neuromuscular stimulation / Peritoneal infection / Biocompatibility / ハイドロキシアパタイトーカ-ボン複合材 / 骨欠損部充填材 / アパタイトーカ-ボン複合材 / ハイドロキシアパタイトコ-ティング / 経皮端子 / 神経刺激用複合セラミック電極 / ハイドロキシアパタイトーカーボン複合材 / ハイドロキシアパタイトコーティング
Research Abstract

Hydroxyapatite percutaneous devices were implanted in human forearms of three volunteers. The percutaneous devices were button-shaped sintered hydroxyapatite ceramics. During the past sixty months since implantation, the devices have been adhering to the epidermis perfectly. The implantation of these hydroxyapatite percutaneous devices have permitted normal daily life, including taking baths and swimming, without any infection.
Button-shaped hydroxyapatite electrical connecting devices were percutaneously implanted in the epidermis of rabbits. Contractions of the calf muscle were elicited by electrical stimuli delivered to intramuscular electrodes through the connector. These results indicated that a hydroxyapatite percutaneous electrical connector could be clinically utilized as an implantable skin interface for functional neuromuscular stimulation (FNS) without any peritoneal infection.
Hydroxyapatite-carbon composite materials were developed for neuromuscular stimulation electrodes. The composite materials have lower resistivity but the same mechanical strength as densely sintered hydroxyapatite ceramics. The biocompatibility of the composites was as good as that of hydroxyapatite, as revealed by tissue reactions implanted under the epidermis of dogs.
The stimulation system was composed of hydroxyapatite-carbon composite electrodes and a hydroxyapatite percutaneous electrical connector. Composite electrodes were implanted into bones of dogs. The connectors were percutaneously implanted in the back skin of the dogs. The alternating current for stimulation was generated by AC-STIM. The histocompatibility of the electrodes to bone tissues was superior to that of metallic electrodes. The composite materials promoted new bone formation and filled bone defects sufficiently, matching hydroxyapatite ceramics.

Report

(4 results)
  • 1990 Annual Research Report   Final Research Report Summary
  • 1989 Annual Research Report
  • 1988 Annual Research Report
  • Research Products

    (13 results)

All Other

All Publications (13 results)

  • [Publications] 伏見 昌樹: "カ-ボンーアパタイト複合材電極の骨組織に対する反応" 生体電気刺激研究会誌. 4. 1-5 (1990)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] Kenzo AKAZAWA: "Eunctional Neuromuscular Stimulation System Using on Implantable Hydroxyapatite Connector and a MicroprocessorーBased Portable Stimulator" IEEE Transactions on Biomedical Engineering. 36. 746-753 (1989)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] 秦 美治: "経皮的に埋入したハイドロキシアパタイト,βーリン酸三カルシウム及びガラス状カ-ボン周囲の組織反応" 人工臓器. 18. 88-91 (1989)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] 青木 秀希: "バイオセラミックス" 生体材料. 7. 24-27 (1989)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] 辻 隆之: "ハイドロキシアパタイト皮膚端子のヒト3例への植え込み実験" 人工臓器. 17. 747-750 (1988)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] M. Fushimi, Y. Okubo, K. Furuya, Y. Ukegawa, T. Shimizu, S. Hasegawa, H. Aoki, K. Yoshizawa, M. Higashikata, Y. Yukawa, S. Imai: "Bone Tissue Reaction to Electrodes composed of Carbon-Apatite Composite." The Journal of the Japanese Bio-Electrical Research Society. 4. 1-5 (1990)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] K. Akazawa, M. Makikawa, J. Kawamura and H. Aoki: "Functional Neuromuscular Stimulation System Using Implantable Hydroxyapatite Connector and a Microprocessor-Based Portable Stimulator." IEEE Transaction on biomedical Engineering. 36. 746-753 (1989)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] Y. Shin, H. Aoki, N. Yoshiyama, T. Tsuji and T. Togawa: "Skin Tissue Reactions to Sintered Hydroxyapatite, beta-Tricalcium Phosphate and Glassy Carbon Percutaneously Implanted in Dogs." The Japanese Journal of Artificial Organs. 18. 88-91 (1989)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] H. Aoki,: "Bioceramics." Journal of Japanese Society for Biomaterials. 7. 24-27 (1989)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] T. Tsuji, T. Togawa, H. Aoki, Y. Ukegawa and Y. shin: "Thirty Months Implantation of Percutaneous Devices Made of Sintered Hydroxyapatite In the Forearms of Three Volunteers." The Japanese Journal of Artificial Organs. 17. 747-750 (1988)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] 伏見 昌樹: "カ-ボンーアパタイト複合材電極の骨組織に対する反応" 生体電気刺激研究会誌. 4. 1-5 (1990)

    • Related Report
      1990 Annual Research Report
  • [Publications] Kenzo Akakzawa: "Functional Neuromuscular Stimulation System Using an Implantable Hydroxyapatite Connector and a Microprocessor-Based Portable Stimulator" IEEE Transactions on Biomedical Engineering. 36. 746-753 (1989)

    • Related Report
      1989 Annual Research Report
  • [Publications] 辻隆之: 人工臓器. 17. 747-750 (1988)

    • Related Report
      1988 Annual Research Report

URL: 

Published: 1988-04-01   Modified: 2016-04-21  